BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

231 related articles for article (PubMed ID: 27268414)

  • 1. The accuracy of blood pressure measured by arterial line and non-invasive cuff in critically ill children.
    Joffe R; Duff J; Garcia Guerra G; Pugh J; Joffe AR
    Crit Care; 2016 Jun; 20(1):177. PubMed ID: 27268414
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?
    Araghi A; Bander JJ; Guzman JA
    Crit Care; 2006; 10(2):R64. PubMed ID: 16630359
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of Noninvasive Blood Pressure Monitoring in Critically Ill Adults.
    Haber EN; Sonti R; Simkovich SM; Pike CW; Boxley CL; Fong A; Weintraub WS; Cobb NK
    J Intensive Care Med; 2024 Jul; 39(7):665-671. PubMed ID: 38215002
    [No Abstract]   [Full Text] [Related]  

  • 4. Accuracy of invasive arterial pressure monitoring in cardiovascular patients: an observational study.
    Romagnoli S; Ricci Z; Quattrone D; Tofani L; Tujjar O; Villa G; Romano SM; De Gaudio AR
    Crit Care; 2014 Nov; 18(6):644. PubMed ID: 25433536
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Oscillometric and intra-arterial blood pressure in children post-kidney transplantation: Is invasive blood pressure measurement always needed?
    Marouane A; Cornelissen EAM; Nusmeier A; Bootsma-Robroeks CMHHT
    Pediatr Transplant; 2019 Feb; 23(1):e13309. PubMed ID: 30362265
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Arterial Pressure Monitoring in Pediatric Patients Undergoing Cardiac Surgery: An Observational Study Comparing Invasive and Non-invasive Measurements.
    Ricci Z; Brogi J; De Filippis S; Caccavelli R; Morlacchi M; Romagnoli S
    Pediatr Cardiol; 2019 Aug; 40(6):1231-1237. PubMed ID: 31222376
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The impact of blood pressure cuff location on the accuracy of noninvasive blood pressure measurements in obese patients: an observational study.
    Anast N; Olejniczak M; Ingrande J; Brock-Utne J
    Can J Anaesth; 2016 Mar; 63(3):298-306. PubMed ID: 26475165
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of filtering methods for acquiring radial intra-artery blood pressure waveforms.
    Hersh LT; Friedman B; Luczyk W; Sesing J
    J Clin Monit Comput; 2015 Oct; 29(5):659-69. PubMed ID: 25516162
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Differences in mean arterial pressure of young and elderly people measured by oscilometry during inflation and deflation of the arm cuff.
    Fabian V; Havlik J; Dvorak J; Kremen V; Sajgalik P; Bellamy V; Schirger JA; Sovka P; Johnson BD
    Biomed Tech (Berl); 2016 Dec; 61(6):611-621. PubMed ID: 26943590
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Noninvasive monitoring of blood pressure in the critically ill: reliability according to the cuff site (arm, thigh, or ankle).
    Lakhal K; Macq C; Ehrmann S; Boulain T; Capdevila X
    Crit Care Med; 2012 Apr; 40(4):1207-13. PubMed ID: 22425818
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prehospital Invasive Arterial Pressure: Use of a Minimized Flush System.
    Karlsson J; Linde J; Svensen C; Gellerfors M
    Prehosp Disaster Med; 2018 Oct; 33(5):490-494. PubMed ID: 30168412
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy and precision of oscillometric noninvasive blood pressure measurement in critically ill patients: systematic review and meta-analysis.
    Nedel W; Vasconcellos A; Gunsch K; Rigotti Soares P
    Anaesthesiol Intensive Ther; 2022; 54(5):425-431. PubMed ID: 36734453
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Non-invasive continuous arterial pressure monitoring with Nexfin does not sufficiently replace invasive measurements in critically ill patients.
    Hohn A; Defosse JM; Becker S; Steffen C; Wappler F; Sakka SG
    Br J Anaesth; 2013 Aug; 111(2):178-84. PubMed ID: 23485882
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Noninvasive BP Monitoring in the Critically Ill: Time to Abandon the Arterial Catheter?
    Lakhal K; Ehrmann S; Boulain T
    Chest; 2018 Apr; 153(4):1023-1039. PubMed ID: 29108815
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of the non-invasive Nexfin® monitor with conventional methods for the measurement of arterial blood pressure in moderate risk orthopaedic surgery patients.
    Balzer F; Habicher M; Sander M; Sterr J; Scholz S; Feldheiser A; Müller M; Perka C; Treskatsch S
    J Int Med Res; 2016 Aug; 44(4):832-43. PubMed ID: 27142436
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Predictors of clinically relevant differences between noninvasive versus arterial blood pressure.
    Raffman A; Shah U; Barr JF; Hassan S; Azike LU; Tanveer S; Bracklow S; Parker B; Haase DJ; Tran QK
    Am J Emerg Med; 2021 May; 43():170-174. PubMed ID: 32169387
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Arterial or cuff pressure: Clinical predictors among patients in shock in a critical care resuscitation unit.
    Keville MP; Gelmann D; Hollis G; Beher R; Raffman A; Tanveer S; Jones K; Parker BM; Haase DJ; Tran QK
    Am J Emerg Med; 2021 Aug; 46():109-115. PubMed ID: 33744746
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Attenuation in invasive blood pressure measurement systems.
    Ercole A
    Br J Anaesth; 2006 May; 96(5):560-2. PubMed ID: 16567344
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of Noninvasive Oscillometric and Intra-Arterial Blood Pressure Measurements in Children Admitted to the Pediatric Intensive Care Unit.
    Kaur J; Bhargava S; Pooni PA; Bhat D; Dhooria GS; Arora K; Kakkar S; Gill K
    J Pediatr Intensive Care; 2024 Jun; 13(2):155-161. PubMed ID: 38919689
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Peripheral arterial blood pressure monitoring adequately tracks central arterial blood pressure in critically ill patients: an observational study.
    Mignini MA; Piacentini E; Dubin A
    Crit Care; 2006; 10(2):R43. PubMed ID: 16542489
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.