  • 41. A novel cuffless device for self-measurement of blood pressure: concept, performance and clinical validation.
    Boubouchairopoulou N; Kollias A; Chiu B; Chen B; Lagou S; Anestis P; Stergiou GS
    J Hum Hypertens; 2017 Jul; 31(7):479-482. PubMed ID: 28124684
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Validation of the single-cuff oscillometric blood pressure monitor InBody BPBIO750 for public spaces according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Ntineri A; Prapa S; Bountzona I; Menti A; Stergiou GS
    Blood Press Monit; 2021 Apr; 26(2):146-148. PubMed ID: 33323723
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Validation of the KANG KC-2850 oscillometric upper-arm ambulatory blood pressure monitor in general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization universal standard.
    Liu K; Ma YF; Wang Y; Zhang Y; Li LY; Zhang JQ; Jiang J; Chen RL; Wan Y
    Blood Press Monit; 2022 Oct; 27(5):349-352. PubMed ID: 35687039
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Validation of the blood pressure measurement technology used in the Novacor Diasys 3 Plus (DIP-0001-00) upper-arm device for ambulatory blood pressure measurement, according to AAMI/ANSI/ISO 81060-2: 2013, ESH-IP 2010 and MEDDEV 2.7/1.
    Atkins N; Fania C; Palatini P
    Blood Press Monit; 2020 Dec; 25(6):359-367. PubMed ID: 33074927
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Accuracy of the COMBEI BP118A Device for Self-Blood Pressure Measurements in General Population - Validation According to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Tasić N; Topouchian J; Tasic D; Kovacevic Z; Filipovic M; Asmar R
    Vasc Health Risk Manag; 2022; 18():123-129. PubMed ID: 35309162
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Validation of the Spacelabs 90227 OnTrak device according to the European and British Hypertension Societies as well as the American protocols.
    de Greeff A; Shennan AH
    Blood Press Monit; 2020 Apr; 25(2):110-114. PubMed ID: 31833949
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Validation of the blood pressure measurement technology used in the Novacor Diasys 3 (DIS-0001-00) upper arm device for ambulatory blood pressure measurement, according to the requirements of the AAMI/ANSI/ISO 81060-2:2013 standard (for both a general study and a cardiac-stress study in adults) and of the European Society of Hypertension International Protocol revision 2010.
    Atkins N; Fania C; Palatini P
    Blood Press Monit; 2021 Feb; 26(1):70-77. PubMed ID: 33234813
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Simultaneous validation of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society and the Association for the Advancement of Medical Instrumentation/the International Organization for Standardization protocols.
    Huang J; Wang Y; Liu Z; Wang Y
    Blood Press Monit; 2017 Feb; 22(1):44-47. PubMed ID: 27749334
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Validation of the Welch Allyn Pro BP 2000, a professional-grade inflation-based automated sphygmomanometer with arrhythmia detection in a combined pediatric and adult population by ANSI/AAMI/ISO standard testing.
    Alpert BS
    Blood Press Monit; 2018 Dec; 23(6):315-317. PubMed ID: 30312180
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Validation of the YuWell YE900 oscillometric blood pressure monitor for professional office use in adults and children according to the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018).
    Zhang HJ; Zhang J; Wang SL; Zhang J; Teng LN; Zhang SJ; Zhou DJ; Long MZ
    Blood Press Monit; 2021 Oct; 26(5):396-399. PubMed ID: 34480474
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Validation of the EDAN SA-10 ambulatory blood pressure monitor in general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Wang B; Liu K; Li L; Yin S; Ren J
    Blood Press Monit; 2022 Aug; 27(4):276-279. PubMed ID: 35438083
    [TBL] [Abstract][Full Text] [Related]  

  • 52. A Universal Standard for the Validation of Blood Pressure Measuring Devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Collaboration Statement.
    Stergiou GS; Alpert B; Mieke S; Asmar R; Atkins N; Eckert S; Frick G; Friedman B; Graßl T; Ichikawa T; Ioannidis JP; Lacy P; McManus R; Murray A; Myers M; Palatini P; Parati G; Quinn D; Sarkis J; Shennan A; Usuda T; Wang J; Wu CO; O'Brien E
    Hypertension; 2018 Mar; 71(3):368-374. PubMed ID: 29386350
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Validation of the InBody BPBIO210 manual auscultatory hybrid device for professional office use in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Ntineri A; Menti A; Kyriakoulis KG; Bountzona I; Prapa S; Kollias A; Stergiou GS
    Blood Press Monit; 2022 Apr; 27(2):135-138. PubMed ID: 34636810
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Validation of the ABPMpro ambulatory blood pressure monitor in the general population according to AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018).
    Roth B; Bothe TL; Patzak A; Pilz N
    Blood Press Monit; 2023 Jun; 28(3):158-162. PubMed ID: 37016982
    [TBL] [Abstract][Full Text] [Related]  

  • 55. A novel professional automated auscultatory blood pressure monitor with visual display of Korotkoff sounds: InBody BPBIO480KV validation according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Ntineri A; Theodosiadi A; Menti A; Kyriakoulis KG; Ntousopoulos V; Kollias A; Stergiou GS
    J Hypertens; 2023 Feb; 41(2):356-361. PubMed ID: 36524556
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Clinical evaluation of the Braun BP 3000 Easy Click according to the ANSI/AAMI SP 10:2002.
    Nolly H; Romero M; Nolly A; Silva M; Nolly M
    Blood Press Monit; 2006 Apr; 11(2):91-5. PubMed ID: 16534411
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Validation of the BIOS BD240 home blood pressure monitor in a multi-racial, multi-morbid Canadian population according to the International Standards Organization 2018 Protocol.
    Ringrose JS; Wood PW; Diaz-Carvallo F; Wirzba M; Padwal R
    Blood Press Monit; 2020 Jun; 25(3):167-170. PubMed ID: 32187037
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Validation of the AViTA upper-arm blood pressure monitor BP636 with multiple cuff sizes in the general population according to the ANSI/AAMI/ISO 81060-2:2018/Amd1:2020.
    Lin CY; Huang IC
    Blood Press Monit; 2024 Aug; ():. PubMed ID: 39129374
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Accuracy of the WatchBP office ABI device for office blood pressure measurement over a wide range of arm sizes.
    Palatini P; Fania C; Gasparotti F
    Blood Press Monit; 2018 Apr; 23(2):117-119. PubMed ID: 29406326
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Clinical evaluation of the oscillometric blood pressure monitor in adults and children based on the 1992 AAMI SP-10 standards.
    Ling J; Ohara Y; Orime Y; Noon GP; Takatani S
    J Clin Monit; 1995 Mar; 11(2):123-30. PubMed ID: 7760085
    [TBL] [Abstract][Full Text] [Related]  