These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 27272509)

  • 1. A single center's conversion from roller pump to centrifugal pump technology in extracorporeal membrane oxygenation.
    Shade BC; Schiavo K; Rosenthal T; Connelly JT; Melchior RW
    Perfusion; 2016 Nov; 31(8):662-667. PubMed ID: 27272509
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Outcomes of neonates undergoing extracorporeal membrane oxygenation support using centrifugal versus roller blood pumps.
    Barrett CS; Jaggers JJ; Cook EF; Graham DA; Rajagopal SK; Almond CS; Seeger JD; Rycus PT; Thiagarajan RR
    Ann Thorac Surg; 2012 Nov; 94(5):1635-41. PubMed ID: 22921236
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Centrifugal pumps and hemolysis in pediatric extracorporeal membrane oxygenation (ECMO) patients: An analysis of Extracorporeal Life Support Organization (ELSO) registry data.
    O'Brien C; Monteagudo J; Schad C; Cheung E; Middlesworth W
    J Pediatr Surg; 2017 Jun; 52(6):975-978. PubMed ID: 28359588
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of pump type on outcomes in neonates with congenital diaphragmatic hernia requiring ECMO.
    Delaplain PT; Zhang L; Nguyen DV; Ashrafi AH; Yu PT; Di Nardo M; Chen Y; Starr J; Ford HR; Guner YS
    Perfusion; 2018 May; 33(1_suppl):71-79. PubMed ID: 29788843
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hemolysis during cardiac extracorporeal membrane oxygenation: a case-control comparison of roller pumps and centrifugal pumps in a pediatric population.
    Byrnes J; McKamie W; Swearingen C; Prodhan P; Bhutta A; Jaquiss R; Imamura M; Fiser R
    ASAIO J; 2011; 57(5):456-61. PubMed ID: 21822124
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Switching to centrifugal pumps may decrease hemolysis rates among pediatric ECMO patients.
    Johnson KN; Carr B; Mychaliska GB; Hirschl RB; Gadepalli SK
    Perfusion; 2022 Mar; 37(2):123-127. PubMed ID: 33459153
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Centrifugal or Roller Blood Pumps for Neonatal Venovenous Extracorporeal Membrane Oxygenation: Extracorporeal Life Support Organization Database Comparison of Mortality and Morbidity.
    Ündar A; Kunselman AR; Barbaro RP; Alexander P; Patel K; Thomas NJ
    Pediatr Crit Care Med; 2023 Aug; 24(8):662-669. PubMed ID: 37102713
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In Vitro Comparison of Two Neonatal ECMO Circuits Using a Roller or Centrifugal Pump With Three Different In-Line Hemoconcentrators for Maintaining Hemodynamic Energy Delivery to the Patient.
    Force M; Moroi M; Wang S; Palanzo DA; Kunselman AR; Ündar A
    Artif Organs; 2018 Apr; 42(4):354-364. PubMed ID: 29323409
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Outcomes of Infants Supported With Extracorporeal Membrane Oxygenation Using Centrifugal Versus Roller Pumps: An Analysis From the Extracorporeal Life Support Organization Registry.
    O'Halloran CP; Thiagarajan RR; Yarlagadda VV; Barbaro RP; Nasr VG; Rycus P; Anders M; Alexander PMA
    Pediatr Crit Care Med; 2019 Dec; 20(12):1177-1184. PubMed ID: 31567621
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Roller and Centrifugal Pumps: A Retrospective Comparison of Bleeding Complications in Extracorporeal Membrane Oxygenation.
    Halaweish I; Cole A; Cooley E; Lynch WR; Haft JW
    ASAIO J; 2015; 61(5):496-501. PubMed ID: 25914954
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of pressure-volume-flow relationships in centrifugal and roller pump extracorporeal membrane oxygenation systems for neonates.
    Green TP; Kriesmer P; Steinhorn RH; Payne NR; Irmiter RJ; Meyer CL
    ASAIO Trans; 1991; 37(4):572-6. PubMed ID: 1768491
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of Centrifugal and Roller Pump Hemolysis Rates at Low Flow.
    Moon YS; Ohtsubo S; Gomez MR; Moon JK; Nose Y
    Artif Organs; 1996 May; 20(5):579-581. PubMed ID: 28868720
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High Hemoglobin Is an Independent Risk Factor for the Development of Hemolysis During Pediatric Extracorporeal Life Support.
    Jenks CL; Zia A; Venkataraman R; Raman L
    J Intensive Care Med; 2019 Mar; 34(3):259-264. PubMed ID: 28486865
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Improved Outcome of Cardiac Extracorporeal Membrane Oxygenation in Infants and Children Using Magnetic Levitation Centrifugal Pumps.
    Luciani GB; Hoxha S; Torre S; Rungatscher A; Menon T; Barozzi L; Faggian G
    Artif Organs; 2016 Jan; 40(1):27-33. PubMed ID: 26608937
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of centrifugal and roller pump hemolysis rates at low flow.
    Moon YS; Ohtsubo S; Gomez MR; Moon JK; Nosé Y
    Artif Organs; 1996 Jun; 20(6):579-81. PubMed ID: 8817960
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Usefulness of extracorporeal membrane oxygenation using double roller pumps in a low body weight newborn: A novel strategy for mechanical circulatory support in an infant.
    Nakanishi K; Kato T; Kawasaki S; Amano A
    Ann Pediatr Cardiol; 2016; 9(1):85-6. PubMed ID: 27011702
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hemolytic characteristics of three commercially available centrifugal blood pumps.
    Lawson DS; Ing R; Cheifetz IM; Walczak R; Craig D; Schulman S; Kern F; Shearer IR; Lodge A; Jaggers J
    Pediatr Crit Care Med; 2005 Sep; 6(5):573-7. PubMed ID: 16148820
    [TBL] [Abstract][Full Text] [Related]  

  • 18. North American neonatal extracorporeal membrane oxygenation (ECMO) devices and team roles: 2008 survey results of Extracorporeal Life Support Organization (ELSO) centers.
    Lawson DS; Lawson AF; Walczak R; McRobb C; McDermott P; Shearer IR; Lodge A; Jaggers J
    J Extra Corpor Technol; 2008 Sep; 40(3):166-74. PubMed ID: 18853828
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pediatric ECMO outcomes: comparison of centrifugal versus roller blood pumps using propensity score matching.
    Barrett CS; Jaggers JJ; Cook EF; Graham DA; Yarlagadda VV; Teele SA; Almond CS; Bratton SL; Seeger JD; Dalton HJ; Rycus PT; Laussen PC; Thiagarajan RR
    ASAIO J; 2013; 59(2):145-51. PubMed ID: 23438777
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Impact of Roller Pump vs. Centrifugal Pump on Homologous Blood Transfusion in Pediatric Cardiac Surgery.
    Datt B; Nguyen MB; Plancher G; Ruzmetov M; O'Brien M; Kube A; Munro HM; Pourmoghadam KK; DeCampli WM
    J Extra Corpor Technol; 2017 Mar; 49(1):36-43. PubMed ID: 28298664
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.