BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

222 related articles for article (PubMed ID: 27273370)

  • 1. Ultrafast Brain MRI: Clinical Deployment and Comparison to Conventional Brain MRI at 3T.
    Prakkamakul S; Witzel T; Huang S; Boulter D; Borja MJ; Schaefer P; Rosen B; Heberlein K; Ratai E; Gonzalez G; Rapalino O
    J Neuroimaging; 2016 Sep; 26(5):503-10. PubMed ID: 27273370
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Role of a modified ultrafast MRI brain protocol in clinical paediatric neuroimaging.
    Ahamed SH; Lee KJ; Tang PH
    Clin Radiol; 2020 Dec; 75(12):914-920. PubMed ID: 32782127
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical feasibility of 1-min ultrafast brain MRI compared with routine brain MRI using synthetic MRI: a single center pilot study.
    Ryu KH; Choi DS; Baek HJ; Cho SB; Ha JY; Kim TB; Hwang MJ
    J Neurol; 2019 Feb; 266(2):431-439. PubMed ID: 30536110
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ultrafast Brain Magnetic Resonance Imaging in Acute Neurological Emergencies: Diagnostic Accuracy and Impact on Patient Management.
    Kazmierczak PM; Dührsen M; Forbrig R; Patzig M; Klein M; Pomschar A; Kunz WG; Puhr-Westerheide D; Ricke J; Solyanik O; Cyran CC
    Invest Radiol; 2020 Mar; 55(3):181-189. PubMed ID: 31917761
    [TBL] [Abstract][Full Text] [Related]  

  • 5. One-Minute Ultrafast Brain MRI With Full Basic Sequences: Can It Be a Promising Way Forward for Pediatric Neuroimaging?
    Ha JY; Baek HJ; Ryu KH; Choi BH; Moon JI; Park SE; Kim TB
    AJR Am J Roentgenol; 2020 Jul; 215(1):198-205. PubMed ID: 32255685
    [No Abstract]   [Full Text] [Related]  

  • 6. Diagnostic equivalency of fast T2 and FLAIR sequences for pediatric brain MRI: a pilot study.
    Jaimes C; Yang E; Connaughton P; Robson CD; Robertson RL
    Pediatr Radiol; 2020 Apr; 50(4):550-559. PubMed ID: 31863192
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Image quality at synthetic brain magnetic resonance imaging in children.
    Lee SM; Choi YH; Cheon JE; Kim IO; Cho SH; Kim WH; Kim HJ; Cho HH; You SK; Park SH; Hwang MJ
    Pediatr Radiol; 2017 Nov; 47(12):1638-1647. PubMed ID: 28638982
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Diagnostic performance of a new multicontrast one-minute full brain exam (EPIMix) in neuroradiology: A prospective study.
    Delgado AF; Kits A; Bystam J; Kaijser M; Skorpil M; Sprenger T; Skare S
    J Magn Reson Imaging; 2019 Dec; 50(6):1824-1833. PubMed ID: 30932287
    [TBL] [Abstract][Full Text] [Related]  

  • 9. T1-weighted fluid-attenuated inversion recovery and T1-weighted fast spin-echo contrast-enhanced imaging: a comparison in 20 patients with brain lesions.
    Al-Saeed O; Ismail M; Athyal RP; Rudwan M; Khafajee S
    J Med Imaging Radiat Oncol; 2009 Aug; 53(4):366-72. PubMed ID: 19695043
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Utility of an ultrafast magnetic resonance imaging protocol in recent and semi-recent strokes.
    U-King-Im JM; Trivedi RA; Graves MJ; Harkness K; Eales H; Joubert I; Koo B; Antoun N; Warburton EA; Gillard JH; Baron JC
    J Neurol Neurosurg Psychiatry; 2005 Jul; 76(7):1002-5. PubMed ID: 15965212
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Automated Brain Volumetry in Patients With Memory Impairment: Comparison of Conventional and Ultrafast 3D T1-Weighted MRI Sequences Using Two Software Packages.
    Heo YJ; Baek HJ; Skare S; Lee HJ; Kim DH; Kim J; Yoon S
    AJR Am J Roentgenol; 2022 Jun; 218(6):1062-1073. PubMed ID: 34985311
    [No Abstract]   [Full Text] [Related]  

  • 12. The applied research of MRI with ASSET-EPI-FLAIR combined with 3D TOF MRA sequences in the assessment of patients with acute cerebral infarction.
    Lin Z; Guo Z; Qiu L; Yang W; Lin M
    Acta Radiol; 2016 Dec; 57(12):1515-1523. PubMed ID: 26853685
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Diagnostic value of 3D fluid attenuated inversion recovery sequence in multiple sclerosis.
    Gramsch C; Nensa F; Kastrup O; Maderwald S; Deuschl C; Ringelstein A; Schelhorn J; Forsting M; Schlamann M
    Acta Radiol; 2015 May; 56(5):622-7. PubMed ID: 24867222
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Brain magnetic resonance imaging at 3 Tesla using BLADE compared with standard rectilinear data sampling.
    Wintersperger BJ; Runge VM; Biswas J; Nelson CB; Stemmer A; Simonetta AB; Reiser MF; Naul LG; Schoenberg SO
    Invest Radiol; 2006 Jul; 41(7):586-92. PubMed ID: 16772852
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Diagnostic Performance of a 10-Minute Gadolinium-Enhanced Brain MRI Protocol Compared with the Standard Clinical Protocol for Detection of Intracranial Enhancing Lesions.
    Fagundes J; Longo MG; Huang SY; Rosen BR; Witzel T; Heberlein K; Gonzalez RG; Schaefer P; Rapalino O
    AJNR Am J Neuroradiol; 2017 Sep; 38(9):1689-1694. PubMed ID: 28705816
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Initial clinical experience of synthetic MRI as a routine neuroimaging protocol in daily practice: A single-center study.
    Ryu KH; Baek HJ; Moon JI; Choi BH; Park SE; Ha JY; Jeon KN; Bae K; Choi DS; Cho SB; Lee Y; Heo YJ
    J Neuroradiol; 2020 Mar; 47(2):151-160. PubMed ID: 30951770
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effective performance of T(1)-weighted FLAIR Imaging with BLADE in pediatric brains.
    Tachibana Y; Niwa T; Kwee TC; Takahara T; Kusagiri K; Nagaoka T; Watanabe R; Aida N
    Magn Reson Med Sci; 2012; 11(1):17-26. PubMed ID: 22450383
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Brain imaging: Comparison of T1W FLAIR BLADE with conventional T1W SE.
    Mavroidis P; Giankou E; Tsikrika A; Kapsalaki E; Chatzigeorgiou V; Batsikas G; Zaimis G; Kostopoulos S; Glotsos D; Ninos K; Georgountzos V; Kavouras D; Lavdas E
    Magn Reson Imaging; 2017 Apr; 37():234-242. PubMed ID: 27939435
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Usefulness of optimized gadolinium-enhanced fast fluid-attenuated inversion recovery MR imaging in revealing lesions of the brain.
    Melhem ER; Bert RJ; Walker RE
    AJR Am J Roentgenol; 1998 Sep; 171(3):803-7. PubMed ID: 9725320
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Neonatal brain: regional variability of in vivo MR imaging relaxation rates at 3.0 T--initial experience.
    Williams LA; Gelman N; Picot PA; Lee DS; Ewing JR; Han VK; Thompson RT
    Radiology; 2005 May; 235(2):595-603. PubMed ID: 15858099
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.