These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

97 related articles for article (PubMed ID: 27277042)

  • 1. A clinically observed discrepancy between image-based and log-based MLC positions.
    Neal B; Ahmed M; Kathuria K; Watkins T; Wijesooriya K; Siebers J
    Med Phys; 2016 Jun; 43(6):2933-2935. PubMed ID: 27277042
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Automating linear accelerator quality assurance.
    Eckhause T; Al-Hallaq H; Ritter T; DeMarco J; Farrey K; Pawlicki T; Kim GY; Popple R; Sharma V; Perez M; Park S; Booth JT; Thorwarth R; Moran JM
    Med Phys; 2015 Oct; 42(10):6074-83. PubMed ID: 26429282
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Implementation of phantom-less IMRT delivery verification using Varian DynaLog files and R/V output.
    Agnew CE; King RB; Hounsell AR; McGarry CK
    Phys Med Biol; 2012 Nov; 57(21):6761-77. PubMed ID: 23032423
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Insensitivity of machine log files to MLC leaf backlash and effect of MLC backlash on clinical dynamic MLC motion: An experimental investigation.
    Barnes M; Pomare D; Doebrich M; Standen TS; Wolf J; Greer P; Simpson J
    J Appl Clin Med Phys; 2022 Sep; 23(9):e13660. PubMed ID: 35678793
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Monitoring daily MLC positional errors using trajectory log files and EPID measurements for IMRT and VMAT deliveries.
    Agnew A; Agnew CE; Grattan MW; Hounsell AR; McGarry CK
    Phys Med Biol; 2014 May; 59(9):N49-63. PubMed ID: 24732210
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A novel quality assurance procedure for trajectory log validation using phantom-less real-time latency corrected EPID images.
    Lim SB; Zwan BJ; Lee D; Greer PB; Lovelock DM
    J Appl Clin Med Phys; 2021 Mar; 22(3):176-185. PubMed ID: 33634952
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quality assurance for online adapted treatment plans: benchmarking and delivery monitoring simulation.
    Li T; Wu Q; Yang Y; Rodrigues A; Yin FF; Jackie Wu Q
    Med Phys; 2015 Jan; 42(1):381-90. PubMed ID: 25563278
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The use of EPID-measured leaf sequence files for IMRT dose reconstruction in adaptive radiation therapy.
    Lee L; Mao W; Xing L
    Med Phys; 2008 Nov; 35(11):5019-29. PubMed ID: 19070236
    [TBL] [Abstract][Full Text] [Related]  

  • 9. MLC quality assurance using EPID: a fitting technique with subpixel precision.
    Mamalui-Hunter M; Li H; Low DA
    Med Phys; 2008 Jun; 35(6):2347-55. PubMed ID: 18649468
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of two methods of predicting MLC leaf positions using EPID measurements.
    Parent L; Seco J; Evans PM; Dance DR; Fielding A
    Med Phys; 2006 Sep; 33(9):3174-82. PubMed ID: 17022210
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dependence of fluence errors in dynamic IMRT on leaf-positional errors varying with time and leaf number.
    Zygmanski P; Kung JH; Jiang SB; Chin L
    Med Phys; 2003 Oct; 30(10):2736-49. PubMed ID: 14596312
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration.
    Baker SJ; Budgell GJ; MacKay RI
    Phys Med Biol; 2005 Apr; 50(7):1377-92. PubMed ID: 15798330
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A high-speed scintillation-based electronic portal imaging device to quantitatively characterize IMRT delivery.
    Ranade MK; Lynch BD; Li JG; Dempsey JF
    Med Phys; 2006 Jan; 33(1):106-10. PubMed ID: 16485415
    [TBL] [Abstract][Full Text] [Related]  

  • 14. EPID-based verification of the MLC performance for dynamic IMRT and VMAT.
    Rowshanfarzad P; Sabet M; Barnes MP; O'Connor DJ; Greer PB
    Med Phys; 2012 Oct; 39(10):6192-207. PubMed ID: 23039657
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of MLC leaf positioning using a scanning liquid ionization chamber EPID.
    Mohammadi M; Bezak E
    Phys Med Biol; 2007 Jan; 52(1):N21-33. PubMed ID: 17183123
    [TBL] [Abstract][Full Text] [Related]  

  • 16. MO-D-BRB-09: Treatment Delivery QA for Online Adaptive Radiation Therapy Based on Dynamic Machine Information (DMI): A Feasibility Study.
    Li T; Yuan L; Wu Q; Yin F; Wu QJ
    Med Phys; 2012 Jun; 39(6Part21):3867-3868. PubMed ID: 28518229
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Verification of multileaf collimator leaf positions using an electronic portal imaging device.
    Samant SS; Zheng W; Parra NA; Chandler J; Gopal A; Wu J; Jain J; Zhu Y; Sontag M
    Med Phys; 2002 Dec; 29(12):2900-12. PubMed ID: 12512727
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical implementation of a commercial multileaf collimator: dosimetry, networking, simulation, and quality assurance.
    Klein EE; Harms WB; Low DA; Willcut V; Purdy JA
    Int J Radiat Oncol Biol Phys; 1995 Dec; 33(5):1195-208. PubMed ID: 7493844
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Phantomless patient-specific TomoTherapy QA via delivery performance monitoring and a secondary Monte Carlo dose calculation.
    Handsfield LL; Jones R; Wilson DD; Siebers JV; Read PW; Chen Q
    Med Phys; 2014 Oct; 41(10):101703. PubMed ID: 25281942
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An experimental investigation into the radiation field offset of a dynamic multileaf collimator.
    Vial P; Oliver L; Greer PB; Baldock C
    Phys Med Biol; 2006 Nov; 51(21):5517-38. PubMed ID: 17047267
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.