These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
187 related articles for article (PubMed ID: 27282617)
1. Magnesium Sulfate as an Alternative In Vitro Anticoagulant for the Measurement of Platelet Parameters? Mannuß S; Schuff-Werner P; Dreißiger K; Kohlschein P Am J Clin Pathol; 2016 Jun; 145(6):806-14. PubMed ID: 27282617 [TBL] [Abstract][Full Text] [Related]
2. Measurement of Platelet Counts and Volume Using Magnesium Sulfate as an Anticoagulant: Comparison of Impedance and Light-Scatter Technology. Mannuß S; Kohlschein P; Dreißiger K; Schuff-Werner P Am J Clin Pathol; 2016 Nov; 146(5):538-545. PubMed ID: 28430955 [TBL] [Abstract][Full Text] [Related]
3. Standardisation of platelet counting accuracy in blood banks by reference to an automated immunoplatelet procedure: comparative evaluation of Cell-Dyn CD4000 impedance and optical platelet counts. Johannessen B; Haugen T; Scott CS Transfus Apher Sci; 2001 Oct; 25(2):93-106. PubMed ID: 11761280 [TBL] [Abstract][Full Text] [Related]
4. Mean platelet volume measurement, EDTA or citrate? Dastjerdi MS; Emami T; Najafian A; Amini M Hematology; 2006 Oct; 11(5):317-9. PubMed ID: 17607580 [TBL] [Abstract][Full Text] [Related]
5. A comparison of platelet parameters in EDTA- and citrate-anticoagulated blood in dogs. Stokol T; Erb HN Vet Clin Pathol; 2007 Jun; 36(2):148-54. PubMed ID: 17523088 [TBL] [Abstract][Full Text] [Related]
6. Effective estimation of correct platelet counts in pseudothrombocytopenia using an alternative anticoagulant based on magnesium salt. Schuff-Werner P; Steiner M; Fenger S; Gross HJ; Bierlich A; Dreissiger K; Mannuß S; Siegert G; Bachem M; Kohlschein P Br J Haematol; 2013 Sep; 162(5):684-92. PubMed ID: 23808903 [TBL] [Abstract][Full Text] [Related]
7. Comparison of platelet count results on the Sysmex XN between citrate or MgSO Soulard M; Croix P; Cohen P Int J Lab Hematol; 2023 Feb; 45(1):20-28. PubMed ID: 36093831 [TBL] [Abstract][Full Text] [Related]
8. The role of anticoagulation in the measurement of platelet volumes. Thompson CB; Diaz DD; Quinn PG; Lapins M; Kurtz SR; Valeri CR Am J Clin Pathol; 1983 Sep; 80(3):327-32. PubMed ID: 6410905 [TBL] [Abstract][Full Text] [Related]
9. The routine measurement of platelet size using sodium citrate alone as the anticoagulant. Bath PM Thromb Haemost; 1993 Oct; 70(4):687-90. PubMed ID: 8115997 [TBL] [Abstract][Full Text] [Related]
10. Do we need time adjusted mean platelet volume measurements? Lancé MD; van Oerle R; Henskens YM; Marcus MA Lab Hematol; 2010 Sep; 16(3):28-31. PubMed ID: 20858586 [TBL] [Abstract][Full Text] [Related]
11. Inhibition of agonist-induced platelet aggregation by magnesium sulfate warrants its use as an alternative in vitro anticoagulant in pseudothrombocytopenia. Mannuß S; Schuff-Werner P; Dreißiger K; Burstein C Platelets; 2020 Jul; 31(5):680-684. PubMed ID: 31509045 [TBL] [Abstract][Full Text] [Related]
12. Estimation of Platelet Counts and Other Hematological Parameters in Pseudothrombocytopenia Using Alternative Anticoagulant: Magnesium Sulfate. Choccalingam C; Radha RKN; Snigdha N Clin Med Insights Blood Disord; 2017; 10():1179545X17705380. PubMed ID: 28579856 [TBL] [Abstract][Full Text] [Related]
13. The platelet count in EDTA-anticoagulated blood from patients with thrombocytopenia may be underestimated when measured in routine laboratories. Podda GM; Pugliano M; Femia EA; Mezzasoma AM; Gresele P; Carpani G; Cattaneo M Am J Hematol; 2012 Jul; 87(7):727-8. PubMed ID: 22674424 [TBL] [Abstract][Full Text] [Related]
14. Differences between the effects of EDTA and citrate anticoagulants on platelet count and mean platelet volume. McShine RL; Sibinga S; Brozovic B Clin Lab Haematol; 1990; 12(3):277-85. PubMed ID: 2125542 [TBL] [Abstract][Full Text] [Related]
15. Effects of sodium citrate and acid citrate dextrose solutions on cell counts and growth factor release from equine pure-platelet rich plasma and pure-platelet rich gel. Giraldo CE; Álvarez ME; Carmona JU BMC Vet Res; 2015 Mar; 11():60. PubMed ID: 25889052 [TBL] [Abstract][Full Text] [Related]
16. Anticoagulant Choices Affect the Mean Platelet Volume Measurement by Impedance. Spezia J; Hermann PB; Comar SR; Picheth G; Henneberg R; Utiyama SRR Clin Lab; 2018 Jan; 64(1):217-220. PubMed ID: 29479892 [TBL] [Abstract][Full Text] [Related]
17. Use of mean platelet component to measure platelet activation on the ADVIA 120 haematology system. Macey MG; Carty E; Webb L; Chapman ES; Zelmanovic D; Okrongly D; Rampton DS; Newland AC Cytometry; 1999 Oct; 38(5):250-5. PubMed ID: 10516612 [TBL] [Abstract][Full Text] [Related]
18. [Platelet count in EDTA-dependent pseudothrombocytopenia--application of MgSO4 as an anticoagulant]. Nakamoto K; Sugibayashi S; Takahashi A; Terauchi S; Hada A; Munakata M; Teraoka A; Komiyama Y; Egawa H; Murata K Rinsho Byori; 1986 Feb; 34(2):167-73. PubMed ID: 3084831 [No Abstract] [Full Text] [Related]
19. [Effects of anticoagulants and storage temperature on immature platelet fraction % (IPF%) values in stored samples measured by the automated hematology analyzer, XE-5000--utility of CTAD-anticoagulation and room temperature storage]. Nishiyama M; Hayashi S; Kabutomori O; Yamanishi H; Suehisa E; Kurata Y; Kashiwagi H; Tomiyama Y Rinsho Byori; 2011 May; 59(5):452-8. PubMed ID: 21706858 [TBL] [Abstract][Full Text] [Related]
20. Preanalytical treatment of EDTA-anticoagulated blood to ensure stabilization of the mean platelet volume and component measured with the ADVIA counters. Diaz-Ricart M; Brunso L; Pino M; Navalon F; Jou JM; Heras M; White JG; Escolar G Thromb Res; 2010 Jul; 126(1):e30-5. PubMed ID: 20427079 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]