BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

313 related articles for article (PubMed ID: 27288865)

  • 1. A new method for vitrifying samples for cryoEM.
    Razinkov I; Dandey V; Wei H; Zhang Z; Melnekoff D; Rice WJ; Wigge C; Potter CS; Carragher B
    J Struct Biol; 2016 Aug; 195(2):190-198. PubMed ID: 27288865
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Optimizing "self-wicking" nanowire grids.
    Wei H; Dandey VP; Zhang Z; Raczkowski A; Rice WJ; Carragher B; Potter CS
    J Struct Biol; 2018 May; 202(2):170-174. PubMed ID: 29317278
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Spotiton: a prototype for an integrated inkjet dispense and vitrification system for cryo-TEM.
    Jain T; Sheehan P; Crum J; Carragher B; Potter CS
    J Struct Biol; 2012 Jul; 179(1):68-75. PubMed ID: 22569522
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Through-grid wicking enables high-speed cryoEM specimen preparation.
    Tan YZ; Rubinstein JL
    Acta Crystallogr D Struct Biol; 2020 Nov; 76(Pt 11):1092-1103. PubMed ID: 33135680
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Shake-it-off: a simple ultrasonic cryo-EM specimen-preparation device.
    Rubinstein JL; Guo H; Ripstein ZA; Haydaroglu A; Au A; Yip CM; Di Trani JM; Benlekbir S; Kwok T
    Acta Crystallogr D Struct Biol; 2019 Dec; 75(Pt 12):1063-1070. PubMed ID: 31793900
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Spotiton: New features and applications.
    Dandey VP; Wei H; Zhang Z; Tan YZ; Acharya P; Eng ET; Rice WJ; Kahn PA; Potter CS; Carragher B
    J Struct Biol; 2018 May; 202(2):161-169. PubMed ID: 29366716
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Specimen Preparation for High-Resolution Cryo-EM.
    Passmore LA; Russo CJ
    Methods Enzymol; 2016; 579():51-86. PubMed ID: 27572723
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fully automated multi-grid cryoEM screening using Smart Leginon.
    Cheng A; Kim PT; Kuang H; Mendez JH; Chua EYD; Maruthi K; Wei H; Sawh A; Aragon MF; Serbynovskyi V; Neselu K; Eng ET; Potter CS; Carragher B; Bepler T; Noble AJ
    IUCrJ; 2023 Jan; 10(Pt 1):77-89. PubMed ID: 36598504
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Strategies for Automated CryoEM Data Collection Using Direct Detectors.
    Cheng A; Tan YZ; Dandey VP; Potter CS; Carragher B
    Methods Enzymol; 2016; 579():87-102. PubMed ID: 27572724
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A novel storage system for cryoEM samples.
    Scapin G; Prosise WW; Wismer MK; Strickland C
    J Struct Biol; 2017 Jul; 199(1):84-86. PubMed ID: 28433496
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Leginon: an automated system for acquisition of images from vitreous ice specimens.
    Carragher B; Kisseberth N; Kriegman D; Milligan RA; Potter CS; Pulokas J; Reilein A
    J Struct Biol; 2000 Oct; 132(1):33-45. PubMed ID: 11121305
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Blotting-free and lossless cryo-electron microscopy grid preparation from nanoliter-sized protein samples and single-cell extracts.
    Arnold SA; Albiez S; Bieri A; Syntychaki A; Adaixo R; McLeod RA; Goldie KN; Stahlberg H; Braun T
    J Struct Biol; 2017 Mar; 197(3):220-226. PubMed ID: 27864160
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cryo-Electron Microscopy Screening Automation across Multiple Grids using Smart Leginon.
    Sawh-Gopal A; Ishemgulova A; Chua EYD; Aragon MF; Mendez JH; Eng ET; Noble AJ
    J Vis Exp; 2023 Dec; (202):. PubMed ID: 38108412
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Vitrification after multiple rounds of sample application and blotting improves particle density on cryo-electron microscopy grids.
    Snijder J; Borst AJ; Dosey A; Walls AC; Burrell A; Reddy VS; Kollman JM; Veesler D
    J Struct Biol; 2017 Apr; 198(1):38-42. PubMed ID: 28254381
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Copper Oxide Spike Grids for Enhanced Solution Transfer in Cryogenic Electron Microscopy.
    Lee D; Lee H; Lee J; Roh SH; Ha NC
    Mol Cells; 2023 Sep; 46(9):538-544. PubMed ID: 37528647
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Manual Blot-and-Plunge Freezing of Biological Specimens for Single-Particle Cryogenic Electron Microscopy.
    Nguyen HPM; McGuire KL; Cook BD; Herzik MA
    J Vis Exp; 2022 Feb; (180):. PubMed ID: 35188117
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Does contamination buildup limit throughput for automated cryoEM?
    Cheng A; Fellmann D; Pulokas J; Potter CS; Carragher B
    J Struct Biol; 2006 Jun; 154(3):303-11. PubMed ID: 16632377
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Automated vitrification of cryo-EM samples with controllable sample thickness using suction and real-time optical inspection.
    Koning RI; Vader H; van Nugteren M; Grocutt PA; Yang W; Renault LLR; Koster AJ; Kamp ACF; Schwertner M
    Nat Commun; 2022 May; 13(1):2985. PubMed ID: 35624105
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The observation of intact hepatic endothelial cells by cryo-electron microscopy.
    Braet F; Bomans PH; Wisse E; Frederik PM
    J Microsc; 2003 Nov; 212(Pt 2):175-85. PubMed ID: 14629567
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Do's and don'ts of cryo-electron microscopy: a primer on sample preparation and high quality data collection for macromolecular 3D reconstruction.
    Cabra V; Samsó M
    J Vis Exp; 2015 Jan; (95):52311. PubMed ID: 25651412
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.