BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

240 related articles for article (PubMed ID: 27289525)

  • 1. Assessment of an alternative calibration technique to record breathing pattern and its variability with respiratory inductive plethysmography.
    Lo WLA; Huang DF
    J Clin Monit Comput; 2017 Aug; 31(4):755-764. PubMed ID: 27289525
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reliability of respiratory tidal volume estimation by means of ambulatory inductive plethysmography.
    Grossman P; Spoerle M; Wilhelm FH
    Biomed Sci Instrum; 2006; 42():193-8. PubMed ID: 16817607
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Tidal volume measurements in newborns using respiratory inductive plethysmography.
    Adams JA; Zabaleta IA; Stroh D; Johnson P; Sackner MA
    Am Rev Respir Dis; 1993 Sep; 148(3):585-88. PubMed ID: 8368627
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Calibration of respiratory inductive plethysmography in lambs receiving intermittent mandatory mechanical ventilation.
    Warren RH; Alderson SH
    Crit Care Med; 1988 Feb; 16(2):161-4. PubMed ID: 3277774
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Inductive plethysmography potential as a surrogate for ventilatory measurements during rest and moderate physical exercise.
    Cabiddu R; Pantoni CB; Mendes RG; Trimer R; Catai AM; Borghi-Silva A
    Braz J Phys Ther; 2016 Mar; 20(2):184-8. PubMed ID: 26982454
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reliability of respiratory inductive plethysmography for measuring tidal volume during exercise.
    Caretti DM; Pullen PV; Premo LA; Kuhlmann WD
    Am Ind Hyg Assoc J; 1994 Oct; 55(10):918-23. PubMed ID: 7977031
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Breathing patterns in infants utilizing respiratory inductive plethysmography.
    Warren RH; Alderson SH
    Chest; 1986 May; 89(5):717-22. PubMed ID: 3698701
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of a priori calibration models for respiratory inductance plethysmography during running.
    Leutheuser H; Heyde C; Gollhofer A; Eskofier BM
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():6393-6. PubMed ID: 25571459
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Calibration of respiratory inductance plethysmograph in preterm infants with different respiratory conditions.
    Emeriaud G; Eberhard A; Benchetrit G; Debillon T; Baconnier P
    Pediatr Pulmonol; 2008 Nov; 43(11):1135-1141. PubMed ID: 18846561
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Calibration of respiratory inductive plethysmography in spontaneously breathing lambs and piglets.
    Warren RH; Alderson SH
    J Dev Physiol; 1986 Aug; 8(4):255-8. PubMed ID: 3760483
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Importance of breath size in calibrating the respiratory inductive plethysmograph.
    Millman RP; Chung DC; Shore ET
    Chest; 1986 Jun; 89(6):840-5. PubMed ID: 3709249
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Calibration of respiratory inductive plethysmography during quiet and active sleep in lambs.
    Warren RH; Fewell JE; Alderson SH
    J Dev Physiol; 1989 Dec; 12(6):347-52. PubMed ID: 2640229
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurement of ventilation in children using the respiratory inductive plethysmograph.
    Tabachnik E; Muller N; Toye B; Levison H
    J Pediatr; 1981 Dec; 99(6):895-9. PubMed ID: 7310582
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A wearable respiratory monitoring device--the between-days variability of calibration.
    Heyde C; Mahler H; Roecker K; Gollhofer A
    Int J Sports Med; 2015 Jan; 36(1):29-34. PubMed ID: 25254900
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of respiratory inductive plethysmography in infants weighing less than 1,500 grams.
    Wilkes DL; Revow M; Bryan MH; England SJ
    Am Rev Respir Dis; 1987 Aug; 136(2):416-9. PubMed ID: 3619201
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reference-Free Adjustment of Respiratory Inductance Plethysmography for Measurements during Physical Exercise.
    Leutheuser H; Heyde C; Roecker K; Gollhofer A; Eskofier BM
    IEEE Trans Biomed Eng; 2017 Dec; 64(12):2836-2846. PubMed ID: 28278451
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy of respiratory inductive plethysmograph over wide range of rib cage and abdominal compartmental contributions to tidal volume in normal subjects and in patients with chronic obstructive pulmonary disease.
    Gonzalez H; Haller B; Watson HL; Sackner MA
    Am Rev Respir Dis; 1984 Aug; 130(2):171-4. PubMed ID: 6465670
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Automated, real-time calibration of the respiratory inductance plethysmograph and its application in newborn infants.
    Bar-Yishay E; Putilov A; Einav S
    Physiol Meas; 2003 Feb; 24(1):149-63. PubMed ID: 12636193
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Respiratory inductive plethysmography as a method for measuring ventilatory parameters in conscious, non-restrained dogs.
    Murphy DJ; Renninger JP; Schramek D
    J Pharmacol Toxicol Methods; 2010; 62(1):47-53. PubMed ID: 20435149
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Calibration of the respiratory inductive plethysmograph with the single position graphic technique. Accuracy in different behavior states in lambs.
    Warren RH; Fewell JE; Alderson SH
    Chest; 1988 Aug; 94(2):325-8. PubMed ID: 3396411
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.