These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
219 related articles for article (PubMed ID: 27295858)
1. [Construction of a 15-plex Rapid STR Multiplex Amplification System]. Han JP; Sun J; Ou Y; Liu P; Ye J; Zhao WW; Wang XQ; Zhang YW; Liu Y; Li CX Fa Yi Xue Za Zhi; 2016 Feb; 32(1):49-53. PubMed ID: 27295858 [TBL] [Abstract][Full Text] [Related]
2. Demonstration of rapid multiplex PCR amplification involving 16 genetic loci. Vallone PM; Hill CR; Butler JM Forensic Sci Int Genet; 2008 Dec; 3(1):42-5. PubMed ID: 19083866 [TBL] [Abstract][Full Text] [Related]
3. Development and validation of a multiplexed Y-chromosome STR genotyping system, Y-PLEX 6, for forensic casework. Sinha SK; Budowle B; Arcot SS; Richey SL; Chakrabor R; Jones MD; Wojtkiewicz PW; Schoenbauer DA; Gross AM; Sinha SK; Shewale JG J Forensic Sci; 2003 Jan; 48(1):93-103. PubMed ID: 12570206 [TBL] [Abstract][Full Text] [Related]
4. Rapid amplification of the RM-Yplex assay. Abuidrees AS; Alghafri RH; Hadi S Electrophoresis; 2016 Oct; 37(21):2817-2821. PubMed ID: 26970423 [TBL] [Abstract][Full Text] [Related]
5. Development of a rapid 21-plex autosomal STR typing system for forensic applications. Yang M; Yin C; Lv Y; Yang Y; Chen J; Yu Z; Liu X; Xu M; Chen F; Wu H; Yan J Electrophoresis; 2016 Oct; 37(21):2789-2799. PubMed ID: 27066765 [TBL] [Abstract][Full Text] [Related]
6. Differential pre-amplification of STR loci for fragmented forensic DNA profiling. Ham SK; Kim SY; Seo BY; Woo KM; Lee SH; Choi CY Electrophoresis; 2016 Nov; 37(22):3002-3009. PubMed ID: 27510307 [TBL] [Abstract][Full Text] [Related]
7. [Forensic application of expressmarker 22 STR loci direct PCR amplification kit]. Zou KN; Cao Y; Xia ZF; Zheng WG; Zhou HG Fa Yi Xue Za Zhi; 2012 Dec; 28(6):448-50. PubMed ID: 23484329 [TBL] [Abstract][Full Text] [Related]
8. Rapid PCR protocols for forensic DNA typing on six thermal cycling platforms. Butts EL; Vallone PM Electrophoresis; 2014 Nov; 35(21-22):3053-61. PubMed ID: 25043912 [TBL] [Abstract][Full Text] [Related]
9. Massively parallel sequencing of 17 commonly used forensic autosomal STRs and amelogenin with small amplicons. Kim EH; Lee HY; Yang IS; Jung SE; Yang WI; Shin KJ Forensic Sci Int Genet; 2016 May; 22():1-7. PubMed ID: 26799314 [TBL] [Abstract][Full Text] [Related]
10. Validation study of a 15-plex rapid STR amplification system for human identification. Han J; Sun J; Zhao L; Zhao W; Liu Y; Li C Forensic Sci Int Genet; 2017 May; 28():71-81. PubMed ID: 28189975 [TBL] [Abstract][Full Text] [Related]
11. TWGDAM validation of a nine-locus and a four-locus fluorescent STR multiplex system. Micka KA; Amiott EA; Hockenberry TL; Sprecher CJ; Lins AM; Rabbach DR; Taylor JA; Bacher JW; Glidewell DE; Gibson SD; Crouse CA; Schumm JW J Forensic Sci; 1999 Nov; 44(6):1243-57. PubMed ID: 10582363 [TBL] [Abstract][Full Text] [Related]
12. Y-chromosome STR system, Y-PLEX 12, for forensic casework: development and validation. Shewale JG; Nasir H; Schneida E; Gross AM; Budowle B; Sinha SK J Forensic Sci; 2004 Nov; 49(6):1278-90. PubMed ID: 15568701 [TBL] [Abstract][Full Text] [Related]
13. A highly discriminating 21 locus Y-STR "megaplex" system designed to augment the minimal haplotype loci for forensic casework. Hanson EK; Ballantyne J J Forensic Sci; 2004 Jan; 49(1):40-51. PubMed ID: 14979342 [TBL] [Abstract][Full Text] [Related]
14. Establishment of Multiplex Amplification System of STR Loci in Xi SH; Qu YL; Xia RC; Xiong L; Chai SY; Tong CL; Tao RY; Li CT Fa Yi Xue Za Zhi; 2022 Apr; 38(2):231-238. PubMed ID: 35899512 [TBL] [Abstract][Full Text] [Related]
15. Real-time forensic DNA analysis at a crime scene using a portable microchip analyzer. Liu P; Yeung SH; Crenshaw KA; Crouse CA; Scherer JR; Mathies RA Forensic Sci Int Genet; 2008 Sep; 2(4):301-9. PubMed ID: 19083840 [TBL] [Abstract][Full Text] [Related]
16. Validation of a male-specific, 12-locus fluorescent short tandem repeat (STR) multiplex. Krenke BE; Viculis L; Richard ML; Prinz M; Milne SC; Ladd C; Gross AM; Gornall T; Frappier JR; Eisenberg AJ; Barna C; Aranda XG; Adamowicz MS; Budowle B Forensic Sci Int; 2005 Feb; 148(1):1-14. PubMed ID: 15607584 [TBL] [Abstract][Full Text] [Related]
17. Expanding beyond the current core STR loci: An exploration of 73 STR markers with increased diversity for enhanced DNA mixture deconvolution. Novroski NMM; Wendt FR; Woerner AE; Bus MM; Coble M; Budowle B Forensic Sci Int Genet; 2019 Jan; 38():121-129. PubMed ID: 30396008 [TBL] [Abstract][Full Text] [Related]
18. Validation of short tandem repeats (STRs) for forensic usage: performance testing of fluorescent multiplex STR systems and analysis of authentic and simulated forensic samples. Moretti TR; Baumstark AL; Defenbaugh DA; Keys KM; Smerick JB; Budowle B J Forensic Sci; 2001 May; 46(3):647-60. PubMed ID: 11373004 [TBL] [Abstract][Full Text] [Related]
19. The development of an 18-locus Y-STR system for forensic casework. Hall A; Ballantyne J Anal Bioanal Chem; 2003 Aug; 376(8):1234-46. PubMed ID: 12830356 [TBL] [Abstract][Full Text] [Related]
20. The next generation of DNA profiling--STR typing by multiplexed PCR--ion-pair RP LC-ESI time-of-flight MS. Pitterl F; Niederstätter H; Huber G; Zimmermann B; Oberacher H; Parson W Electrophoresis; 2008 Dec; 29(23):4739-50. PubMed ID: 19053072 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]