These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 27297937)

  • 1. Nanohydroxyapatite promotes the healing process in open-wedge high tibial osteotomy: A CT study.
    Conteduca F; Di Sette P; Iorio R; Caperna L; Argento G; Mazza D; Ferretti A
    Knee; 2016 Oct; 23(5):763-9. PubMed ID: 27297937
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mid-term CT assessment of bone healing after nanohydroxyapatite augmentation in open-wedge high tibial osteotomy.
    Drogo P; Andreozzi V; Rossini M; Caperna L; Iorio R; Mazza D; Ferretti A; Conteduca F
    Knee; 2020 Aug; 27(4):1167-1175. PubMed ID: 32711878
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Remodeling potentials of biphasic calcium phosphate granules in open wedge high tibial osteotomy.
    Ozalay M; Sahin O; Akpinar S; Ozkoc G; Cinar M; Cesur N
    Arch Orthop Trauma Surg; 2009 Jun; 129(6):747-52. PubMed ID: 19015864
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Lateral hinge fracture delays healing of the osteotomy gap in opening wedge high tibial osteotomy with a beta-tricalcium phosphate block.
    Kumagai K; Yamada S; Nejima S; Muramatsu S; Akamatsu Y; Inaba Y
    Knee; 2020 Jan; 27(1):192-197. PubMed ID: 31883759
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Radiographic and computed tomographic evaluation of bone union after medial opening wedge high tibial osteotomy with filling gap.
    Kobayashi H; Akamatsu Y; Kumagai K; Kusayama Y; Saito T
    Knee; 2017 Oct; 24(5):1108-1117. PubMed ID: 28797873
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Bone autografting in medial open wedge high tibial osteotomy results in improved osseous gap healing on computed tomography, but no functional advantage: a prospective, randomised, controlled trial.
    Fucentese SF; Tscholl PM; Sutter R; Brucker PU; Meyer DC; Koch PP
    Knee Surg Sports Traumatol Arthrosc; 2019 Sep; 27(9):2951-2957. PubMed ID: 30456568
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Retrospective Comparison of Union Rates After Open Wedge High Tibial Osteotomies With and Without Synthetic Bone Grafts (Hydroxyapatite and β-tricalciumphosphate) at 2 Years.
    Nha KW; Oh SM; Ha YW; Nikumbha VP; Seo JH; Oh MJ; Lim CO; Kim JG
    Arthroscopy; 2018 Sep; 34(9):2621-2630. PubMed ID: 30078690
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Bone marrow-derived cell mobilization by G-CSF to enhance osseointegration of bone substitute in high tibial osteotomy.
    Marmotti A; Castoldi F; Rossi R; Marenco S; Risso A; Ruella M; Tron A; Borrè A; Blonna D; Tarella C
    Knee Surg Sports Traumatol Arthrosc; 2013 Jan; 21(1):237-48. PubMed ID: 22872005
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Full weight bearing and dynamisation with Limmed® locked plate fixation accelerates bone regeneration in the volume of opening wedge high tibial osteotomy.
    Hernigou P; Flouzat Lachaniette C; Delambre J; Guissou I; Dahmani O; Ibrahim Ouali M; Poignard A
    Int Orthop; 2015 Jul; 39(7):1295-300. PubMed ID: 25532861
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of bone healing and outcomes between allogenous bone chip and hydroxyapatite chip grafts in open wedge high tibial osteotomy.
    Lee OS; Lee KJ; Lee YS
    J Mater Sci Mater Med; 2017 Nov; 28(12):189. PubMed ID: 29101660
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Opening-wedge high tibial osteotomy with and without bone graft.
    Zorzi AR; da Silva HG; Muszkat C; Marques LC; Cliquet A; de Miranda JB
    Artif Organs; 2011 Mar; 35(3):301-7. PubMed ID: 21128980
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparable bone union progression after opening wedge high tibial osteotomy using allogenous bone chip or tri-calcium phosphate granule: a prospective randomized controlled trial.
    Lee DY; Lee MC; Ha CW; Kyung HS; Kim CW; Chang MJ; Han HS
    Knee Surg Sports Traumatol Arthrosc; 2019 Sep; 27(9):2945-2950. PubMed ID: 30377715
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of osteoconductivity and absorbability of beta-tricalcium phosphate and hydroxyapatite in clinical scenario of opening wedge high tibial osteotomy.
    Oh KJ; Ko YB; Jaiswal S; Whang IC
    J Mater Sci Mater Med; 2016 Dec; 27(12):179. PubMed ID: 27757780
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The role of bone void fillers in medial opening wedge high tibial osteotomy: a systematic review.
    Slevin O; Ayeni OR; Hinterwimmer S; Tischer T; Feucht MJ; Hirschmann MT
    Knee Surg Sports Traumatol Arthrosc; 2016 Nov; 24(11):3584-3598. PubMed ID: 27557796
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Is a synthetic augmentation in medial open wedge high tibial osteotomies superior to no augmentation in terms of bone-healing?
    Ferner F; Dickschas J; Ostertag H; Poske U; Schwitulla J; Harrer J; Strecker W
    Knee; 2016 Jan; 23(1):2-7. PubMed ID: 26563647
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High tibial osteotomy using polycaprolactone-tricalcium phosphate polymer wedge in a micro pig model.
    Lim HC; Bae JH; Song HR; Teoh SH; Kim HK; Kum DH
    J Bone Joint Surg Br; 2011 Jan; 93(1):120-5. PubMed ID: 21196556
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Earlier consolidation and improved knee function of medial open wedge high tibial osteotomy with autologous bone graft.
    Bodenbeck EM; Böpple JC; Doll J; Bürkle F; Schmidmaier G; Fischer C
    Eur J Orthop Surg Traumatol; 2024 Jan; 34(1):371-378. PubMed ID: 37540246
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Large opening gaps, unstable hinge fractures, and osteotomy line below the safe zone cause delayed bone healing after open-wedge high tibial osteotomy.
    Goshima K; Sawaguchi T; Shigemoto K; Iwai S; Nakanishi A; Inoue D; Shima Y
    Knee Surg Sports Traumatol Arthrosc; 2019 Apr; 27(4):1291-1298. PubMed ID: 30539305
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Resorbability of rigid beta-tricalcium phosphate wedges in open-wedge high tibial osteotomy: a retrospective radiological study.
    Kraal T; Mullender M; de Bruine JH; Reinhard R; de Gast A; Kuik DJ; van Royen BJ
    Knee; 2008 Jun; 15(3):201-5. PubMed ID: 18411054
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Novel unidirectional porous hydroxyapatite used as a bone substitute for open wedge high tibial osteotomy.
    Uemura K; Kanamori A; Aoto K; Yamazaki M; Sakane M
    J Mater Sci Mater Med; 2014 Nov; 25(11):2541-7. PubMed ID: 24997164
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.