770 related articles for article (PubMed ID: 27300325)
21. Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery.
Mayer J; Boldt J; Schöllhorn T; Röhm KD; Mengistu AM; Suttner S
Br J Anaesth; 2007 Feb; 98(2):176-82. PubMed ID: 17218375
[TBL] [Abstract][Full Text] [Related]
22. Ability of the third-generation FloTrac/Vigileo software to track changes in cardiac output in cardiac surgery patients: a polar plot approach.
Desebbe O; Henaine R; Keller G; Koffel C; Garcia H; Rosamel P; Obadia JF; Bastien O; Lehot JJ; Haftek M; Critchley LA
J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1122-7. PubMed ID: 24011911
[TBL] [Abstract][Full Text] [Related]
23. Cardiac output estimation using multi-beat analysis of the radial arterial blood pressure waveform: a method comparison study in patients having off-pump coronary artery bypass surgery using intermittent pulmonary artery thermodilution as the reference method.
Saugel B; Heeschen J; Hapfelmeier A; Romagnoli S; Greiwe G
J Clin Monit Comput; 2020 Aug; 34(4):649-654. PubMed ID: 31456072
[TBL] [Abstract][Full Text] [Related]
24. The Ability of esCCO and ECOM Monitors to Measure Trends in Cardiac Output During Alveolar Recruitment Maneuver After Cardiac Surgery: A Comparison with the Pulmonary Thermodilution Method.
Thonnerieux M; Alexander B; Binet C; Obadia JF; Bastien O; Desebbe O
Anesth Analg; 2015 Aug; 121(2):383-91. PubMed ID: 25902321
[TBL] [Abstract][Full Text] [Related]
25. Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery bypass grafting.
Smetkin AA; Hussain A; Kuzkov VV; Bjertnæs LJ; Kirov MY
Br J Anaesth; 2014 Jun; 112(6):1024-31. PubMed ID: 24531685
[TBL] [Abstract][Full Text] [Related]
26. Uncalibrated radial and femoral arterial pressure waveform analysis for continuous cardiac output measurement: an evaluation in cardiac surgery patients.
Hofer CK; Button D; Weibel L; Genoni M; Zollinger A
J Cardiothorac Vasc Anesth; 2010 Apr; 24(2):257-64. PubMed ID: 19700349
[TBL] [Abstract][Full Text] [Related]
27. Accuracy, Precision, and Trending Ability of Uncalibrated Arterial Pressure Waveform Analysis of Cardiac Output in Patients With Impaired Left Ventricular Function: A Prospective, Observational Study.
Montenij LJ; Sonneveld JP; Nierich AP; Buhre WF; De Waal EE
J Cardiothorac Vasc Anesth; 2016 Jan; 30(1):115-21. PubMed ID: 26520028
[TBL] [Abstract][Full Text] [Related]
28. Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters.
Hadian M; Kim HK; Severyn DA; Pinsky MR
Crit Care; 2010; 14(6):R212. PubMed ID: 21092290
[TBL] [Abstract][Full Text] [Related]
29. Accuracy and trending ability of the fourth-generation FloTrac/Vigileo System™ in patients undergoing abdominal aortic aneurysm surgery.
Maeda T; Hattori K; Sumiyoshi M; Kanazawa H; Ohnishi Y
J Anesth; 2018 Jun; 32(3):387-393. PubMed ID: 29616345
[TBL] [Abstract][Full Text] [Related]
30. Comparison of calibrated and uncalibrated arterial pressure-based cardiac output monitors during orthotopic liver transplantation.
Krejci V; Vannucci A; Abbas A; Chapman W; Kangrga IM
Liver Transpl; 2010 Jun; 16(6):773-82. PubMed ID: 20517912
[TBL] [Abstract][Full Text] [Related]
31. Bioreactance and fourth-generation pulse contour methods in monitoring cardiac index during off-pump coronary artery bypass surgery.
Ylikauma LA; Ohtonen PP; Erkinaro TM; Vakkala MA; Liisanantti JH; Satta JU; Juvonen TS; Kaakinen TI
J Clin Monit Comput; 2022 Jun; 36(3):879-888. PubMed ID: 34037919
[TBL] [Abstract][Full Text] [Related]
32. Cardiac output measured by uncalibrated arterial pressure waveform analysis by recently released software version 3.02 versus thermodilution in septic shock.
Slagt C; de Leeuw MA; Beute J; Rijnsburger E; Hoeksema M; Mulder JW; Malagon I; Groeneveld AB
J Clin Monit Comput; 2013 Apr; 27(2):171-7. PubMed ID: 23154918
[TBL] [Abstract][Full Text] [Related]
33. Evaluation of the Fourth-Generation FloTrac/Vigileo System in Comparison With the Intermittent Bolus Thermodilution Method in Patients Undergoing Cardiac Surgery.
Kusaka Y; Ohchi F; Minami T
J Cardiothorac Vasc Anesth; 2019 Apr; 33(4):953-960. PubMed ID: 30077561
[TBL] [Abstract][Full Text] [Related]
34. Arterial pressure waveform analysis versus thermodilution cardiac output measurement during open abdominal aortic aneurysm repair: a prospective observational study.
Montenij LJ; Buhre WF; de Jong SA; Harms JH; van Herwaarden JA; Kruitwagen CL; de Waal EE
Eur J Anaesthesiol; 2015 Jan; 32(1):13-9. PubMed ID: 25303970
[TBL] [Abstract][Full Text] [Related]
35. Evaluation of a new software version of the FloTrac/Vigileo (version 3.02) and a comparison with previous data in cirrhotic patients undergoing liver transplant surgery.
Biancofiore G; Critchley LA; Lee A; Yang XX; Bindi LM; Esposito M; Bisà M; Meacci L; Mozzo R; Filipponi F
Anesth Analg; 2011 Sep; 113(3):515-22. PubMed ID: 21680855
[TBL] [Abstract][Full Text] [Related]
36. Cardiac output derived from arterial pressure waveform analysis: validation of the third-generation software in patients undergoing orthotopic liver transplantation.
Tsai YF; Su BC; Lin CC; Liu FC; Lee WC; Yu HP
Transplant Proc; 2012 Mar; 44(2):433-7. PubMed ID: 22410036
[TBL] [Abstract][Full Text] [Related]
37. Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery.
Breukers RM; Sepehrkhouy S; Spiegelenberg SR; Groeneveld AB
J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):632-5. PubMed ID: 17905265
[TBL] [Abstract][Full Text] [Related]
38. Uncalibrated arterial pressure waveform analysis for less-invasive cardiac output determination in obese patients undergoing cardiac surgery.
Mayer J; Boldt J; Beschmann R; Stephan A; Suttner S
Br J Anaesth; 2009 Aug; 103(2):185-90. PubMed ID: 19482857
[TBL] [Abstract][Full Text] [Related]
39. Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery.
Button D; Weibel L; Reuthebuch O; Genoni M; Zollinger A; Hofer CK
Br J Anaesth; 2007 Sep; 99(3):329-36. PubMed ID: 17631509
[TBL] [Abstract][Full Text] [Related]
40. Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes.
Suehiro K; Tanaka K; Funao T; Matsuura T; Mori T; Nishikawa K
Br J Anaesth; 2013 Aug; 111(2):170-7. PubMed ID: 23479677
[TBL] [Abstract][Full Text] [Related]