These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 273090)

  • 1. Radiographic evaluation of porosities in removable partial denture castings.
    Lewis AJ
    J Prosthet Dent; 1978 Mar; 39(3):278-81. PubMed ID: 273090
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Radiographic detection of porosities in removable partial denture castings.
    Elarbi EA; Ismail YH; Azarbal M; Saini TS
    J Prosthet Dent; 1985 Nov; 54(5):674-7. PubMed ID: 3903139
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Investigation of the effect of three sprue designs on the porosity and the completeness of titanium cast removable partial denture frameworks.
    al-Mesmar HS; Morgano SM; Mark LE
    J Prosthet Dent; 1999 Jul; 82(1):15-21. PubMed ID: 10384162
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Failure of removable partial denture castings during service.
    Lewis AJ
    J Prosthet Dent; 1978 Feb; 39(2):147-9. PubMed ID: 340667
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Radiographic and metallographic evaluation of porosity defects and grain structure of cast chromium cobalt removable partial dentures.
    Dharmar S; Rathnasamy RJ; Swaminathan TN
    J Prosthet Dent; 1993 Apr; 69(4):369-73. PubMed ID: 8463964
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A metallographic evaluation of porosity occurring in removable partial denture castings.
    Lewis AJ
    Aust Dent J; 1979 Dec; 24(6):408-11. PubMed ID: 295207
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fabrication of titanium removable dental prosthesis frameworks with a 2-step investment coating method.
    Koike M; Hummel SK; Ball JD; Okabe T
    J Prosthet Dent; 2012 Jun; 107(6):393-9. PubMed ID: 22633596
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Surface roughness and internal porosity of partial removable dental prosthesis frameworks fabricated from conventional wax and light-polymerized patterns: a comparative study.
    Swelem AA; Abdelnabi MH; Al-Dharrab AA; AbdelMaguid HF
    J Prosthet Dent; 2014 Apr; 111(4):335-41. PubMed ID: 24360012
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Button versus buttonless castings for removable partial denture frameworks.
    Mohammed H; Hassaballa MA; Talic YF
    J Prosthet Dent; 1994 Oct; 72(4):433-44. PubMed ID: 7990051
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of titanium and cobalt-chromium removable partial denture clasps.
    Bridgeman JT; Marker VA; Hummel SK; Benson BW; Pace LL
    J Prosthet Dent; 1997 Aug; 78(2):187-93. PubMed ID: 9260137
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Sprue design in removable partial denture casting.
    Burnett CA; Maguire H
    J Dent; 1996; 24(1-2):99-103. PubMed ID: 8636502
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparative study of the centrifugal and vacuum-pressure techniques of casting removable partial denture frameworks.
    Shanley JJ; Ancowitz SJ; Fenster RK; Pelleu GB
    J Prosthet Dent; 1981 Jan; 45(1):18-23. PubMed ID: 7007622
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Internal porosity of cast titanium removable partial dentures: Influence of sprue direction on porosity in circumferential clasps of a clinical framework design.
    Baltag I; Watanabe K; Kusakari H; Miyakawa O
    J Prosthet Dent; 2002 Aug; 88(2):151-8. PubMed ID: 12397242
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of aluminium on the metallography of a nickel base removable partial denture casting alloy.
    Lewis AJ
    Aust Dent J; 1978 Dec; 23(6):488-91. PubMed ID: 285671
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dimensional changes in casting titanium removable partial denture frameworks.
    Blackman R; Barghi N; Tran C
    J Prosthet Dent; 1991 Feb; 65(2):309-15. PubMed ID: 2051371
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Casting titanium partial denture frameworks: a radiographic evaluation.
    Cecconi BT; Koeppen RG; Phoenix RD; Cecconi ML
    J Prosthet Dent; 2002 Mar; 87(3):277-80. PubMed ID: 11941354
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Titanium for removable dentures. I. Laboratory procedures.
    Mori T; Togaya T; Jean-Louis M; Yabugami M
    J Oral Rehabil; 1997 May; 24(5):338-41. PubMed ID: 9183026
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The tooth-removable partial denture interface.
    Brudvik JS; Reimers D
    J Prosthet Dent; 1992 Dec; 68(6):924-7. PubMed ID: 1494121
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The metallography of heat treatment effects in a nickel-base casting alloy. A preliminary report.
    Goodall TG; Lewis AJ
    Aust Dent J; 1979 Aug; 24(4):235-7. PubMed ID: 296698
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A simple method for inspection of porosity in titanium castings.
    Wang RR; Boyle AM
    J Prosthet Dent; 1993 Sep; 70(3):275-6. PubMed ID: 8410737
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.