284 related articles for article (PubMed ID: 2731400)
1. Myocardial perfusion imaging with a new radiotracer, technetium-99m-hexamibi (methoxy isobutyl isonitrile): comparison with thallium-201 imaging.
Taillefer R; Dupras G; Sporn V; Rigo P; Leveille J; Boucher P; Perez-Balino N; Camin LL; McKusick KA
Clin Nucl Med; 1989 Feb; 14(2):89-96. PubMed ID: 2731400
[TBL] [Abstract][Full Text] [Related]
2. Clinical comparison between thallium-201 and Tc-99m-methoxy isobutyl isonitrile (hexamibi) myocardial perfusion imaging for detection of coronary artery disease.
Taillefer R; Lambert R; Dupras G; Grégoire J; Léveillé J; Essiambre R; Phaneuf DC
Eur J Nucl Med; 1989; 15(6):280-6. PubMed ID: 2527750
[TBL] [Abstract][Full Text] [Related]
3. Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging.
Wackers FJ; Berman DS; Maddahi J; Watson DD; Beller GA; Strauss HW; Boucher CA; Picard M; Holman BL; Fridrich R
J Nucl Med; 1989 Mar; 30(3):301-11. PubMed ID: 2525610
[TBL] [Abstract][Full Text] [Related]
4. Same day injections of Tc-99m methoxy isobutyl isonitrile (hexamibi) for myocardial tomographic imaging: comparison between rest-stress and stress-rest injection sequences.
Taillefer R; Gagnon A; Laflamme L; Grégoire J; Léveillé J; Phaneuf DC
Eur J Nucl Med; 1989; 15(3):113-7. PubMed ID: 2785451
[TBL] [Abstract][Full Text] [Related]
5. Comments to: Clinical Comparison Between Thallium 201 and Tc-99m-Methoxy Isobutyl Isonitrile (Hexamibi) Myocardial Perfusion Imaging for Detection of Coronary Artery Disease.
Whalley DR
Eur J Nucl Med; 1989; 15(12):805. PubMed ID: 2625129
[No Abstract] [Full Text] [Related]
6. Comparison of technetium 99m methoxy isobutyl isonitrile and thallium 201 for evaluation of coronary artery disease by planar and tomographic methods.
Kiat H; Maddahi J; Roy LT; Van Train K; Friedman J; Resser K; Berman DS
Am Heart J; 1989 Jan; 117(1):1-11. PubMed ID: 2643279
[TBL] [Abstract][Full Text] [Related]
7. The utilization of technetium-99m CPI as a myocardial perfusion imaging agent in exercise studies.
Sia ST; Holman BL; Campbell S; Lister-James J; English RJ; Kronauge JF; Davison A; Jones AG
Clin Nucl Med; 1987 Sep; 12(9):681-7. PubMed ID: 3665310
[TBL] [Abstract][Full Text] [Related]
8. Technetium-99m sestamibi myocardial imaging: same-day rest-stress studies and dipyridamole.
Taillefer R
Am J Cardiol; 1990 Oct; 66(13):80E-84E. PubMed ID: 2145751
[TBL] [Abstract][Full Text] [Related]
9. Simultaneous assessment of left ventricular wall motion and myocardial perfusion at rest and during exercise by technetium-99m methoxy isobutyl isonitrile.
Takeishi Y; Tono-oka I; Chiba J; Abe S; Tsuiki K; Tomoike H; Yasui S
Jpn Circ J; 1991 Dec; 55(12):1192-9. PubMed ID: 1837319
[TBL] [Abstract][Full Text] [Related]
10. Use of technetium-99m isonitrile (RP-30A) in assessing left ventricular perfusion and function at rest and during exercise in coronary artery disease, and comparison with coronary arteriography and exercise thallium-201 SPECT imaging.
Iskandrian AS; Heo J; Kong B; Lyons E; Marsch S
Am J Cardiol; 1989 Aug; 64(5):270-5. PubMed ID: 2526991
[TBL] [Abstract][Full Text] [Related]
11. Simultaneous measurement of ventricular function and myocardial perfusion using the technetium-99m isonitriles.
Sporn V; Perez Balino N; Holman BL; Sosa Liprandi A; Masoli O; Mitta A; Camin LL; Castiglia S; McKusick KA
Clin Nucl Med; 1988 Feb; 13(2):77-81. PubMed ID: 3349720
[TBL] [Abstract][Full Text] [Related]
12. Effect of ischemia and postischemic dysfunction on myocardial uptake of technetium-99m-labeled methoxyisobutyl isonitrile and thallium-201.
Sinusas AJ; Watson DD; Cannon JM; Beller GA
J Am Coll Cardiol; 1989 Dec; 14(7):1785-93. PubMed ID: 2584570
[TBL] [Abstract][Full Text] [Related]
13. Simultaneous assessment of left ventricular wall motion and myocardial perfusion with technetium-99m-methoxy isobutyl isonitrile at stress and rest in patients with angina: comparison with thallium-201 SPECT.
Villanueva-Meyer J; Mena I; Narahara KA
J Nucl Med; 1990 Apr; 31(4):457-63. PubMed ID: 2324821
[TBL] [Abstract][Full Text] [Related]
14. [Study of myocardial perfusion at rest using technetium Tc 99m methoxy-isobutylisonitrile: comparison with labeled microspheres and thallium 201].
Santoro GM; Bisi G; Sciagrà R; Antoniucci D; De Cristofaro MT; Dovellini EV; Pupi A; Zerauschek M; Fazzini PF
G Ital Cardiol; 1988 Nov; 18(11):907-13. PubMed ID: 3266855
[TBL] [Abstract][Full Text] [Related]
15. Comparison between thallium-201, technetium-99m-sestamibi and technetium-99m-teboroxime planar myocardial perfusion imaging in detection of coronary artery disease.
Taillefer R; Lambert R; Essiambre R; Phaneuf DC; Léveillé J
J Nucl Med; 1992 Jun; 33(6):1091-8. PubMed ID: 1534575
[TBL] [Abstract][Full Text] [Related]
16. Comparison of thallium-201 and technetium-99m hexakis 2-methoxyisobutyl isonitrile single-photon emission computed tomography for estimating the extent of myocardial ischemia and infarction in coronary artery disease.
Narahara KA; Villanueva-Meyer J; Thompson CJ; Brizendine M; Mena I
Am J Cardiol; 1990 Dec; 66(20):1438-44. PubMed ID: 2147536
[TBL] [Abstract][Full Text] [Related]
17. ECG-gated and static technetium-99m-SESTAMIBI planar myocardial perfusion imaging: a comparison with thallium-201 and study of observer variabilities.
Verzijlbergen JF; Cramer MJ; Niemeyer MG; Ascoop CA; Van der Wall EE; Pauwels EK
Am J Physiol Imaging; 1990; 5(2):60-7. PubMed ID: 2147553
[TBL] [Abstract][Full Text] [Related]
18. [Double injection of Tc99m-methoxy isobutyl isonitrile in the same session: diagnostic accuracy in tomography compared with that of thallium-201 chloride].
Tartagni F; Dondi M; Maiello L; Fallani F; Antonioli P; Franchi R; Corbelli C; Yun LX; Magnani B
Cardiologia; 1990 Jul; 35(7):581-90. PubMed ID: 2088603
[TBL] [Abstract][Full Text] [Related]
19. Comparison between technetium-99m-teboroxime and thallium-201 dipyridamole planar myocardial perfusion imaging in detection of coronary artery disease.
Labonté C; Taillefer R; Lambert R; Basile F; TonThat T; Jarry M; Léveillé J
Am J Cardiol; 1992 Jan; 69(1):90-6. PubMed ID: 1729873
[TBL] [Abstract][Full Text] [Related]
20. Quantitative rotational tomography with 201Tl and 99mTc 2-methoxy-isobutyl-isonitrile. A direct comparison in normal individuals and patients with coronary artery disease.
Kahn JK; McGhie I; Akers MS; Sills MN; Faber TL; Kulkarni PV; Willerson JT; Corbett JR
Circulation; 1989 Jun; 79(6):1282-93. PubMed ID: 2785873
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]