These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
228 related articles for article (PubMed ID: 27323369)
1. Developing Non-Somatotopic Phantom Finger Sensation to Comparable Levels of Somatotopic Sensation through User Training With Electrotactile Stimulation. Chai G; Zhang D; Zhu X IEEE Trans Neural Syst Rehabil Eng; 2017 May; 25(5):469-480. PubMed ID: 27323369 [TBL] [Abstract][Full Text] [Related]
2. Somatotopical feedback versus non-somatotopical feedback for phantom digit sensation on amputees using electrotactile stimulation. Zhang D; Xu H; Shull PB; Liu J; Zhu X J Neuroeng Rehabil; 2015 May; 12():44. PubMed ID: 25929589 [TBL] [Abstract][Full Text] [Related]
3. Artificial redirection of sensation from prosthetic fingers to the phantom hand map on transradial amputees: vibrotactile versus mechanotactile sensory feedback. Antfolk C; D'Alonzo M; Controzzi M; Lundborg G; Rosén B; Sebelius F; Cipriani C IEEE Trans Neural Syst Rehabil Eng; 2013 Jan; 21(1):112-20. PubMed ID: 23033439 [TBL] [Abstract][Full Text] [Related]
4. Phantom digit somatotopy: a functional magnetic resonance imaging study in forearm amputees. Björkman A; Weibull A; Olsrud J; Ehrsson HH; Rosén B; Björkman-Burtscher IM Eur J Neurosci; 2012 Jul; 36(1):2098-106. PubMed ID: 22537316 [TBL] [Abstract][Full Text] [Related]
5. Electro-cutaneous stimulation on the palm elicits referred sensations on intact but not on amputated digits. D' Alonzo M; Engels LF; Controzzi M; Cipriani C J Neural Eng; 2018 Feb; 15(1):016003. PubMed ID: 28741593 [TBL] [Abstract][Full Text] [Related]
6. Dissociation of phantom limb phenomena from stump tactile spatial acuity and sensory thresholds. Hunter JP; Katz J; Davis KD Brain; 2005 Feb; 128(Pt 2):308-20. PubMed ID: 15634736 [TBL] [Abstract][Full Text] [Related]
7. Characterization of evoked tactile sensation in forearm amputees with transcutaneous electrical nerve stimulation. Chai G; Sui X; Li S; He L; Lan N J Neural Eng; 2015 Dec; 12(6):066002. PubMed ID: 26401550 [TBL] [Abstract][Full Text] [Related]
8. Vibrotactile detection thresholds for chest skin of amputees following targeted reinnervation surgery. Schultz AE; Marasco PD; Kuiken TA Brain Res; 2009 Jan; 1251():121-9. PubMed ID: 19059226 [TBL] [Abstract][Full Text] [Related]
9. Fusion of dual modalities of non-invasive sensory feedback for object profiling with prosthetic hands. Zhang J; Chou CH; Hao M; Li Y; Yu Y; Lan N Front Neurorobot; 2023; 17():1298176. PubMed ID: 38162892 [TBL] [Abstract][Full Text] [Related]
10. Residual function in peripheral nerve stumps of amputees: implications for neural control of artificial limbs. Dhillon GS; Lawrence SM; Hutchinson DT; Horch KW J Hand Surg Am; 2004 Jul; 29(4):605-15; discussion 616-8. PubMed ID: 15249083 [TBL] [Abstract][Full Text] [Related]
11. Effects of Different Tactile Feedback on Myoelectric Closed-Loop Control for Grasping Based on Electrotactile Stimulation. Xu H; Zhang D; Huegel JC; Xu W; Zhu X IEEE Trans Neural Syst Rehabil Eng; 2016 Aug; 24(8):827-36. PubMed ID: 26372430 [TBL] [Abstract][Full Text] [Related]
12. Stability of phantom limb phenomena after upper limb amputation: a longitudinal study. Hunter JP; Katz J; Davis KD Neuroscience; 2008 Oct; 156(4):939-49. PubMed ID: 18755249 [TBL] [Abstract][Full Text] [Related]
13. The relationship of perceptual phenomena and cortical reorganization in upper extremity amputees. Grüsser SM; Winter C; Mühlnickel W; Denke C; Karl A; Villringer K; Flor H Neuroscience; 2001; 102(2):263-72. PubMed ID: 11166112 [TBL] [Abstract][Full Text] [Related]
14. Towards optimizing the non-invasive sensory feedback interfaces in a neural prosthetic control. Su S; Chai G; Meng J; Sheng X; Mouraux A; Zhu X J Neural Eng; 2022 Feb; 19(1):. PubMed ID: 35073525 [No Abstract] [Full Text] [Related]
15. Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin. Antfolk C; Björkman A; Frank SO; Sebelius F; Lundborg G; Rosen B J Rehabil Med; 2012 Jul; 44(8):702-7. PubMed ID: 22729800 [TBL] [Abstract][Full Text] [Related]
16. Comparative Evaluation of Tactile Sensation by Electrical and Mechanical Stimulation. Yem V; Kajimoto H IEEE Trans Haptics; 2017; 10(1):130-134. PubMed ID: 28113382 [TBL] [Abstract][Full Text] [Related]
17. Abnormal access of axial vibrotactile input to deafferented somatosensory cortex in human upper limb amputees. Kew JJ; Halligan PW; Marshall JC; Passingham RE; Rothwell JC; Ridding MC; Marsden CD; Brooks DJ J Neurophysiol; 1997 May; 77(5):2753-64. PubMed ID: 9163390 [TBL] [Abstract][Full Text] [Related]
18. Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees. Marasco PD; Kim K; Colgate JE; Peshkin MA; Kuiken TA Brain; 2011 Mar; 134(Pt 3):747-58. PubMed ID: 21252109 [TBL] [Abstract][Full Text] [Related]
19. Evaluation of multiple perceptual qualities of transcutaneous electrical nerve stimulation for evoked tactile sensation in forearm amputees. Zhang J; Hao M; Yang F; Liang W; Sun A; Chou CH; Lan N J Neural Eng; 2022 Apr; 19(2):. PubMed ID: 35320789 [No Abstract] [Full Text] [Related]
20. Functional expansion of sensorimotor representation and structural reorganization of callosal connections in lower limb amputees. Simões EL; Bramati I; Rodrigues E; Franzoi A; Moll J; Lent R; Tovar-Moll F J Neurosci; 2012 Feb; 32(9):3211-20. PubMed ID: 22378892 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]