These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
6. Frequency multiplexed superconducting quantum interference device readout of large bolometer arrays for cosmic microwave background measurements. Dobbs MA; Lueker M; Aird KA; Bender AN; Benson BA; Bleem LE; Carlstrom JE; Chang CL; Cho HM; Clarke J; Crawford TM; Crites AT; Flanigan DI; de Haan T; George EM; Halverson NW; Holzapfel WL; Hrubes JD; Johnson BR; Joseph J; Keisler R; Kennedy J; Kermish Z; Lanting TM; Lee AT; Leitch EM; Luong-Van D; McMahon JJ; Mehl J; Meyer SS; Montroy TE; Padin S; Plagge T; Pryke C; Richards PL; Ruhl JE; Schaffer KK; Schwan D; Shirokoff E; Spieler HG; Staniszewski Z; Stark AA; Vanderlinde K; Vieira JD; Vu C; Westbrook B; Williamson R Rev Sci Instrum; 2012 Jul; 83(7):073113. PubMed ID: 22852677 [TBL] [Abstract][Full Text] [Related]
7. Linearized superconducting quantum interference device array for high bandwidth frequency-domain readout multiplexing. Lanting T; Dobbs M; Spieler H; Lee AT; Yamamoto Y Rev Sci Instrum; 2009 Sep; 80(9):094501. PubMed ID: 19791952 [TBL] [Abstract][Full Text] [Related]
8. Expanding the Capability of Microwave Multiplexed Readout for Fast Signals in Microcalorimeters. Morgan KM; Becker DT; Bennett DA; Gard JD; Imrek J; Mates JAB; Pappas CG; Reintsema CD; Schmidt DR; Ullom JN; Weber J; Wessels A; Swetz DS J Low Temp Phys; 2019; 199():. PubMed ID: 33335337 [TBL] [Abstract][Full Text] [Related]
9. Performance and uniformity of a kilo-pixel array of Ti/Au transition-edge sensor microcalorimeters. Taralli E; D'Andrea M; Gottardi L; Nagayoshi K; Ridder ML; de Wit M; Vaccaro D; Akamatsu H; Bruijn MP; Gao JR Rev Sci Instrum; 2021 Feb; 92(2):023101. PubMed ID: 33648117 [TBL] [Abstract][Full Text] [Related]
10. Frequency shift algorithm: Application to a frequency-domain multiplexing readout of x-ray transition-edge sensor microcalorimeters. Vaccaro D; Akamatsu H; van der Kuur J; van der Hulst P; Nieuwenhuizen ACT; van Winden P; Gottardi L; den Hartog R; Bruijn MP; D'Andrea M; Gao JR; den Herder JWA; Hoogeveen RWM; Jackson B; van der Linden AJ; Nagayoshi K; Ravensberg K; Ridder ML; Taralli E; de Wit M Rev Sci Instrum; 2021 Mar; 92(3):033103. PubMed ID: 33820098 [TBL] [Abstract][Full Text] [Related]
11. Frequency shift algorithm: Design of a baseband phase locked loop for frequency-domain multiplexing readout of x-ray transition-edge sensor microcalorimeters. van der Hulst P; van der Kuur J; Nieuwenhuizen A; Vaccaro D; Akamatsu H; van Winden P; van Leeuwen BJ; den Herder JW Rev Sci Instrum; 2021 Jul; 92(7):073101. PubMed ID: 34340431 [TBL] [Abstract][Full Text] [Related]
12. Use of Transition Models to Design High Performance TESs for the LCLS-II Soft X-Ray Spectrometer. Morgan KM; Becker DT; Bennett DA; Doriese WB; Gard JD; Irwin KD; Lee SJ; Li D; Mates JAB; Pappas CG; Schmidt DR; Titus CJ; Van Winkle DD; Ullom JN; Wessels A; Swetz DS IEEE Trans Appl Supercond; 2019; 29(5):. PubMed ID: 33456289 [TBL] [Abstract][Full Text] [Related]
16. Configurable error correction of code-division multiplexed TES detectors with a cryotron switch. Weber JC; Fowler JW; Durkin M; Morgan KM; Mates JAB; Bennett DA; Doriese WB; Schmidt DR; Hilton GC; Swetz DS; Ullom JN Appl Phys Lett; 2019; 114(23):. PubMed ID: 38487744 [TBL] [Abstract][Full Text] [Related]
17. Frequency division multiplexing readout of a transition edge sensor bolometer array with microstrip-type electrical bias lines. Wang Q; Khosropanah P; van der Kuur J; de Lange G; Audley MD; Aminaei A; Ilyas S; Ridder ML; van der Linden AJ; Bruijn MP; van der Tak F; Gao JR Rev Sci Instrum; 2022 Dec; 93(12):124901. PubMed ID: 36586892 [TBL] [Abstract][Full Text] [Related]