BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 27328388)

  • 1. High-frequency ultrasound measurement of dermis and subcutaneous fat in the newborn infant.
    Petersen JR; Petersen S; Serup J
    Skin Res Technol; 1995 May; 1(2):86-9. PubMed ID: 27328388
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Body composition in sport: a comparison of a novel ultrasound imaging technique to measure subcutaneous fat tissue compared with skinfold measurement.
    Müller W; Horn M; Fürhapter-Rieger A; Kainz P; Kröpfl JM; Maughan RJ; Ahammer H
    Br J Sports Med; 2013 Nov; 47(16):1028-35. PubMed ID: 24055780
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of ultrasound and skinfold caliper measurement of subcutaneous fat tissue.
    Weits T; van der Beek EJ; Wedel M
    Int J Obes; 1986; 10(3):161-8. PubMed ID: 3531051
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of ultrasound and skinfold measurements in assessment of subcutaneous and total fatness.
    Borkan GA; Hults DE; Cardarelli J; Burrows BA
    Am J Phys Anthropol; 1982 Jul; 58(3):307-13. PubMed ID: 7124924
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Skinfold caliper and ultrasound assessments of change in the distribution of subcutaneous fat during adolescent pregnancy.
    Stevens-Simon C; Thureen P; Barrett J; Stamm E
    Int J Obes Relat Metab Disord; 2001 Sep; 25(9):1340-5. PubMed ID: 11571597
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Comparative measurement of skinfold thickness of the back of the hand with caliper and ultrasound--initial results of a prospective study].
    Stautner-Brückmann C; Reitmeier K; Gresser U; Zöllner N
    Bildgebung; 1990; 57(3-4):67-9. PubMed ID: 2091815
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measurement of subcutaneous fat thickness with high frequency pulsed ultrasound: comparisons with a caliper and a radiographic technique.
    Black D; Vora J; Hayward M; Marks R
    Clin Phys Physiol Meas; 1988 Feb; 9(1):57-64. PubMed ID: 3282753
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of near infra-red interactance for assessment of subcutaneous and total body fat.
    Brooke-Wavell K; Jones PR; Norgan NG; Hardman AE
    Eur J Clin Nutr; 1995 Jan; 49(1):57-65. PubMed ID: 7713052
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Estimation of body fat from ultrasound measures of subcutaneous fat and circumferences in obese women.
    Fanelli MT; Kuczmarski RJ; Hirsch M
    Int J Obes; 1988; 12(2):125-32. PubMed ID: 3290131
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Maternal diabetes and neonatal macrosomia. Dynamic skinfold thickness measurements.
    West DL; Brans YW
    Am J Perinatol; 1986 Jan; 3(1):9-12. PubMed ID: 3942618
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Estimation of total body fat and subcutaneous adipose tissue in full-term infants less than 3 months old.
    Kabir N; Forsum E
    Pediatr Res; 1993 Oct; 34(4):448-54. PubMed ID: 8255676
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ultrasound as an approach to assessing body composition.
    Fanelli MT; Kuczmarski RJ
    Am J Clin Nutr; 1984 May; 39(5):703-9. PubMed ID: 6711473
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of ultrasound and caliper measurements of normal and inflamed skin thickness.
    Lawrence CM; Shuster S
    Br J Dermatol; 1985 Feb; 112(2):195-200. PubMed ID: 3882127
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quantitative measurement of muscle and subcutaneous fat thickness in newborn by real-time ultrasonography: a useful method for site and depth evaluation in vaccination.
    Lo YS; Lu CC; Chen LY; Huang LY; Jong YJ
    Gaoxiong Yi Xue Ke Xue Za Zhi; 1992 Feb; 8(2):75-81. PubMed ID: 1404527
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of total body fat using the skinfold technique in full-term and preterm infants.
    Olhager E; Forsum E
    Acta Paediatr; 2006 Jan; 95(1):21-8. PubMed ID: 16373292
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of Skinfold Thickness Measured by Caliper and Ultrasound Scanner in Normative Weight Women.
    Lewandowski Z; Dychała E; Pisula-Lewandowska A; Danel DP
    Int J Environ Res Public Health; 2022 Dec; 19(23):. PubMed ID: 36498301
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Methodological aspects of high-frequency ultrasound of skin in children.
    Schou AJ; Thomsen K; Plomgaard AM; Wolthers OD
    Skin Res Technol; 2004 Aug; 10(3):200-6. PubMed ID: 15225271
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ultrasonic and skinfold caliper measures of subcutaneous adipose tissue thickness in elderly men and women.
    Chumlea WC; Roche AF
    Am J Phys Anthropol; 1986 Nov; 71(3):351-7. PubMed ID: 3544855
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A-mode and B-mode ultrasound measurement of fat thickness: a cadaver validation study.
    Wagner DR; Thompson BJ; Anderson DA; Schwartz S
    Eur J Clin Nutr; 2019 Apr; 73(4):518-523. PubMed ID: 29391591
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ultrasound image of healthy skin in newborns in the first 24 hours of life.
    Przybysz P; Jackowska T; Wilińska M; Malinowska S; Wójtowicz J; Mlosek RK
    J Ultrason; 2021; 20(83):e242-e247. PubMed ID: 33500790
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.