BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 27335760)

  • 1. Coupled molecular and cantilever dynamics model for frequency-modulated atomic force microscopy.
    Klocke M; Wolf DE
    Beilstein J Nanotechnol; 2016; 7():708-20. PubMed ID: 27335760
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dissipation signals due to lateral tip oscillations in FM-AFM.
    Klocke M; Wolf DE
    Beilstein J Nanotechnol; 2014; 5():2048-57. PubMed ID: 25551032
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Computational model for noncontact atomic force microscopy: energy dissipation of cantilever.
    Senda Y; Blomqvist J; Nieminen RM
    J Phys Condens Matter; 2016 Sep; 28(37):375001. PubMed ID: 27420398
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Energy dissipation and dynamic response of an amplitude-modulation atomic-force microscopy subjected to a tip-sample viscous force.
    Lin SM
    Ultramicroscopy; 2007; 107(2-3):245-53. PubMed ID: 16982149
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Atom-resolved analysis of an ionic KBr(001) crystal surface covered with a thin water layer by frequency modulation atomic force microscopy.
    Arai T; Koshioka M; Abe K; Tomitori M; Kokawa R; Ohta M; Yamada H; Kobayashi K; Oyabu N
    Langmuir; 2015 Apr; 31(13):3876-83. PubMed ID: 25790119
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantitative determination of the interaction potential between two surfaces using frequency-modulated atomic force microscopy.
    Chan N; Lin C; Jacobs T; Carpick RW; Egberts P
    Beilstein J Nanotechnol; 2020; 11():729-739. PubMed ID: 32461874
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Advanced tip design for liquid phase vibration mode atomic force microscopy.
    Muramatsu H; Yamamoto Y; Shigeno M; Shirakawabe Y; Inoue A; Kim WS; Kim SJ; Chang SM; Kim JM
    Anal Chim Acta; 2008 Mar; 611(2):233-8. PubMed ID: 18328326
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Molecular dynamics simulation of bimodal atomic force microscopy.
    Dou Z; Qian J; Li Y; Wang Z; Zhang Y; Lin R; Wang T
    Ultramicroscopy; 2020 May; 212():112971. PubMed ID: 32126474
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Contact stiffness and damping of liquid films in dynamic atomic force microscope.
    Xu RG; Leng Y
    J Chem Phys; 2016 Apr; 144(15):154702. PubMed ID: 27389229
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of solution concentration, surface bias and protonation on the dynamic response of amplitude-modulated atomic force microscopy in water.
    Wu Y; Gupta C; Shannon MA
    Langmuir; 2008 Oct; 24(19):10817-24. PubMed ID: 18763814
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A measurement of the hysteresis loop in force-spectroscopy curves using a tuning-fork atomic force microscope.
    Lange M; van Vörden D; Möller R
    Beilstein J Nanotechnol; 2012; 3():207-12. PubMed ID: 22496993
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The influence of a Si cantilever tip with/without tungsten coating on noncontact atomic force microscopy imaging of a Ge(001) surface.
    Naitoh Y; Kinoshita Y; Jun Li Y; Kageshima M; Sugawara Y
    Nanotechnology; 2009 Jul; 20(26):264011. PubMed ID: 19509444
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fabrication of electron beam deposited tip for atomic-scale atomic force microscopy in liquid.
    Miyazawa K; Izumi H; Watanabe-Nakayama T; Asakawa H; Fukuma T
    Nanotechnology; 2015 Mar; 26(10):105707. PubMed ID: 25697199
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Theoretical study of the frequency shift in bimodal FM-AFM by fractional calculus.
    Herruzo ET; Garcia R
    Beilstein J Nanotechnol; 2012; 3():198-206. PubMed ID: 22496992
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Nonlinear Dynamics and Chaos of Microcantilever-Based TM-AFMs with Squeeze Film Damping Effects.
    Zhang WM; Meng G; Zhou JB; Chen JY
    Sensors (Basel); 2009; 9(5):3854-74. PubMed ID: 22412340
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Feedback based simultaneous correction of imaging artifacts due to geometrical and mechanical cross-talk and tip-sample stick in atomic force microscopy.
    Shegaonkar AC; Salapaka SM
    Rev Sci Instrum; 2007 Oct; 78(10):103706. PubMed ID: 17979427
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characterization of distance-dependent damping in tapping-mode atomic force microscopy force measurements in liquid.
    Nnebe I; Schneider JW
    Langmuir; 2004 Apr; 20(8):3195-201. PubMed ID: 15875848
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reduction of the damping on an AFM cantilever in fluid by the use of micropillars.
    Kawakami M; Taniguchi Y; Hiratsuka Y; Shimoike M; Smith DA
    Langmuir; 2010 Jan; 26(2):1002-7. PubMed ID: 19785459
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Models of atomic scale contrast in dissipation images of binary ionic surfaces in non-contact atomic force microscopy.
    Trevethan T; Kantorovich L
    Nanotechnology; 2006 Apr; 17(7):S205-12. PubMed ID: 21727416
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Tapping mode imaging and measurements with an inverted atomic force microscope.
    Chan SS; Green JB
    Langmuir; 2006 Jul; 22(15):6701-6. PubMed ID: 16831016
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.