BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 27338511)

  • 1. Prospective comparative clinical study of ceramic and metallic femoral components for total knee arthroplasty over a five-year follow-up period.
    Bergschmidt P; Ellenrieder M; Bader R; Kluess D; Finze S; Schwemmer B; Mittelmeier W
    Knee; 2016 Oct; 23(5):871-6. PubMed ID: 27338511
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Prospective multi-centre study on a composite ceramic femoral component in total knee arthroplasty: Five-year clinical and radiological outcomes.
    Bergschmidt P; Bader R; Ganzer D; Hauzeur C; Lohmann CH; Krüger A; Rüther W; Tigani D; Rani N; Esteve JL; Prats FL; Zorzi C; Madonna V; Rigotti S; Benazzo F; Rossi SM; Mittelmeier W
    Knee; 2015 Jun; 22(3):186-91. PubMed ID: 25805085
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Total knee replacement system with a ceramic femoral component versus two traditional metallic designs: a prospective short-term study.
    Bergschmidt P; Bader R; Kluess D; Zietz C; Schwemmer B; Kundt G; Mittelmeier W
    J Orthop Surg (Hong Kong); 2013 Dec; 21(3):294-9. PubMed ID: 24366787
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Long-Term Durability of Ceramic Tri-Condylar Knee Implants: A Minimum 15-Year Follow-Up.
    Nakamura S; Ito H; Nakamura K; Kuriyama S; Furu M; Matsuda S
    J Arthroplasty; 2017 Jun; 32(6):1874-1879. PubMed ID: 28209274
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The 2018 Mark Coventry, MD Award: Does a Ceramic Bearing Improve Pain, Function, Wear, or Survivorship of TKA in Patients Younger Than 55 Years of Age? A Randomized Trial.
    Kim YH; Park JW; Kim JS
    Clin Orthop Relat Res; 2019 Jan; 477(1):49-57. PubMed ID: 30794228
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Clinical evaluation of the ceramic femoral component used for reconstruction of total knee replacement].
    Vavrík P; Landor I; Denk F
    Acta Chir Orthop Traumatol Cech; 2008 Dec; 75(6):436-42. PubMed ID: 19150000
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical outcomes of ceramic femoral prosthesis in total knee arthroplasty: a systematic review.
    Xiang S; Zhao Y; Li Z; Feng B; Weng X
    J Orthop Surg Res; 2019 Feb; 14(1):57. PubMed ID: 30782186
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ceramic femoral components in total knee arthroplasty - two year follow-up results of an international prospective multi-centre study.
    Bergschmidt P; Bader R; Ganzer D; Hauzeur C; Lohmann C; Rüther W; Tigani D; Rani N; Prats FL; Zorzi C; Madonna V; Rigotti S; Benazzo F; Rossi SM; Kundt G; Bloch HR; Mittelmeier W
    Open Orthop J; 2012; 6():172-8. PubMed ID: 22582104
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Bi-Surface total knee arthroplasty: minimum 10-year follow-up study.
    Nakamura S; Kobayashi M; Ito H; Nakamura K; Ueo T; Nakamura T
    Knee; 2010 Aug; 17(4):274-8. PubMed ID: 20303765
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Total knee arthroplasty with an oxidised zirconium femoral component: ten-year survivorship analysis.
    Ahmed I; Salmon LJ; Waller A; Watanabe H; Roe JP; Pinczewski LA
    Bone Joint J; 2016 Jan; 98-B(1):58-64. PubMed ID: 26733516
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of a standard and a gender-specific posterior cruciate-substituting high-flexion knee prosthesis: a prospective, randomized, short-term outcome study.
    Kim YH; Choi Y; Kim JS
    J Bone Joint Surg Am; 2010 Aug; 92(10):1911-20. PubMed ID: 20720134
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical results of alumina medial pivot total knee arthroplasty at a minimum follow-up of 10years.
    Nakamura S; Minoda Y; Nakagawa S; Kadoya Y; Takemura S; Kobayashi A; Mizokawa S; Ohta Y; Takahashi S; Yamamura K; Nakamura H
    Knee; 2017 Mar; 24(2):434-438. PubMed ID: 28189408
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Third-body abrasive wear of tibial polyethylene inserts combined with metallic and ceramic femoral components in a knee simulator study.
    Zietz C; Bergschmidt P; Lange R; Mittelmeier W; Bader R
    Int J Artif Organs; 2013 Jan; 36(1):47-55. PubMed ID: 23335379
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fixation of high-flexion total knee prostheses: five-year follow-up results of a four-arm randomized controlled clinical and roentgen stereophotogrammetric analysis study.
    Nieuwenhuijse MJ; van der Voort P; Kaptein BL; van der Linden-van der Zwaag HM; Valstar ER; Nelissen RG
    J Bone Joint Surg Am; 2013 Oct; 95(19):e1411-11. PubMed ID: 24088976
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Total knee replacement with ceramic femoral components: a national prospective multicenter study of clinical and radiological outcomes].
    Bergschmidt P; Lohmann C; Ganzer D; Bader R; Finze S; Kundt G; Hauzeur C; Lukas C; Rüther W; Mittelmeier W
    Orthopade; 2011 Mar; 40(3):224-30. PubMed ID: 21052635
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Metal hypersensitivity in total knee arthroplasty: revision surgery using a ceramic femoral component - a case report.
    Bergschmidt P; Bader R; Mittelmeier W
    Knee; 2012 Mar; 19(2):144-7. PubMed ID: 21292491
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prospective Comparison of a Metal-Free Ceramic Total Knee Arthroplasty with an Identical Metal System.
    Trieb K; Ullmann D; Metzinger K; Kramar R; Mauerer A; Hofstätter S; Fiala R
    Z Orthop Unfall; 2018 Feb; 156(1):46-52. PubMed ID: 29471557
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Long-Term Survivorship and Clinical Outcomes of a Single Radius Total Knee Arthroplasty.
    Mistry JB; Elmallah RK; Chughtai M; Oktem M; Harwin SF; Mont MA
    Surg Technol Int; 2016 Apr; 28():247-51. PubMed ID: 27042782
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Oxidized zirconium femoral component for TKA: a follow-up note of a previous report at a minimum of 10 years.
    Innocenti M; Matassi F; Carulli C; Nistri L; Civinini R
    Knee; 2014 Aug; 21(4):858-61. PubMed ID: 24835580
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A 13- to 16-year clinical and radiological outcome study of the genesis II cruciate retaining total knee arthroplasty with an oxidised zirconium femoral component.
    Papasoulis E; Karachalios T
    Knee; 2019 Mar; 26(2):492-499. PubMed ID: 30773254
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.