147 related articles for article (PubMed ID: 27345704)
1. Tribo-biological deposits on the articulating surfaces of metal-on-polyethylene total hip implants retrieved from patients.
Cui Z; Tian YX; Yue W; Yang L; Li Q
Sci Rep; 2016 Jun; 6():28376. PubMed ID: 27345704
[TBL] [Abstract][Full Text] [Related]
2. Characterization and tribology of PEG-like coatings on UHMWPE for total hip replacements.
Kane SR; Ashby PD; Pruitt LA
J Biomed Mater Res A; 2010 Mar; 92(4):1500-9. PubMed ID: 19425047
[TBL] [Abstract][Full Text] [Related]
3. [New metod for quantification of UHMWPE wear particles around joint replacements].
Pokorný D; Slouf M; Dybal J; Zolotarevová E; Veselý F; Jahoda D; Vavrík P; Landor I; Entlicher G; Sosna A
Acta Chir Orthop Traumatol Cech; 2009 Oct; 76(5):374-81. PubMed ID: 19912700
[TBL] [Abstract][Full Text] [Related]
4. Implant wear mechanisms--basic approach.
Bhatt H; Goswami T
Biomed Mater; 2008 Dec; 3(4):042001. PubMed ID: 18824778
[TBL] [Abstract][Full Text] [Related]
5. The Biotribology of PEEK-on-HXLPE Bearings Is Comparable to Traditional Bearings on a Multidirectional Pin-on-disk Tester.
Baykal D; Siskey RS; Underwood RJ; Briscoe A; Kurtz SM
Clin Orthop Relat Res; 2016 Nov; 474(11):2384-2393. PubMed ID: 27457625
[TBL] [Abstract][Full Text] [Related]
6. A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene.
Sakoda H; Voice AM; McEwen HM; Isaac GH; Hardaker C; Wroblewski BM; Fisher J
J Arthroplasty; 2001 Dec; 16(8):1018-23. PubMed ID: 11740757
[TBL] [Abstract][Full Text] [Related]
7. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.
Goldsmith AA; Dowson D; Isaac GH; Lancaster JG
Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049
[TBL] [Abstract][Full Text] [Related]
8. Tribological behavior of artificial hip joint under the effects of magnetic field in dry and lubricated sliding.
Zaki M; Aljinaidi A; Hamed M
Biomed Mater Eng; 2003; 13(3):205-21. PubMed ID: 12883170
[TBL] [Abstract][Full Text] [Related]
9. Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions.
Affatato S; Bersaglia G; Rocchi M; Taddei P; Fagnano C; Toni A
Biomaterials; 2005 Jun; 26(16):3259-67. PubMed ID: 15603821
[TBL] [Abstract][Full Text] [Related]
10. Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear.
Davidson JA
Clin Orthop Relat Res; 1993 Sep; (294):361-78. PubMed ID: 8358943
[TBL] [Abstract][Full Text] [Related]
11. Prediction of scratch resistance of cobalt chromium alloy bearing surface, articulating against ultra-high molecular weight polyethylene, due to third-body wear particles.
Mirghany M; Jin ZM
Proc Inst Mech Eng H; 2004; 218(1):41-50. PubMed ID: 14982345
[TBL] [Abstract][Full Text] [Related]
12. Attachment of human primary osteoblast cells to modified polyethylene surfaces.
Poulsson AH; Mitchell SA; Davidson MR; Johnstone AJ; Emmison N; Bradley RH
Langmuir; 2009 Apr; 25(6):3718-27. PubMed ID: 19275183
[TBL] [Abstract][Full Text] [Related]
13. Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris.
Davidson JA; Poggie RA; Mishra AK
Biomed Mater Eng; 1994; 4(3):213-29. PubMed ID: 7950870
[TBL] [Abstract][Full Text] [Related]
14. Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement.
Wang A; Essner A; Klein R
Proc Inst Mech Eng H; 2001; 215(2):133-9. PubMed ID: 11382072
[TBL] [Abstract][Full Text] [Related]
15. Surface modifications induced by in-vitro wear and oxidation on γ-irradiated UHMWPE hip liners belonging to different commercial generations.
Puppulin L; Negra SD; Sugano N; Sbaizero O; Pezzotti G
J Mech Behav Biomed Mater; 2016 Jan; 53():414-426. PubMed ID: 26409232
[TBL] [Abstract][Full Text] [Related]
16. [Method for assessment of distribution of UHMWPE wear particles in periprosthetic tissues in total hip arthroplasty].
Pokorný D; Slouf M; Horák Z; Jahoda D; Entlicher G; Eklová S; Sosna A
Acta Chir Orthop Traumatol Cech; 2006 Aug; 73(4):243-50. PubMed ID: 17026883
[TBL] [Abstract][Full Text] [Related]
17. Study on torsional fretting wear behavior of a ball-on-socket contact configuration simulating an artificial cervical disk.
Wang S; Wang F; Liao Z; Wang Q; Liu Y; Liu W
Mater Sci Eng C Mater Biol Appl; 2015 Oct; 55():22-33. PubMed ID: 26117735
[TBL] [Abstract][Full Text] [Related]
18. Steady-state elastohydrodynamic lubrication analysis of a metal-on-metal hip implant employing a metallic cup with an ultra-high molecular weight polyethylene backing.
Liu F; Wang FC; Jin ZM; Hirt F; Rieker C; Grigoris P
Proc Inst Mech Eng H; 2004; 218(4):261-70. PubMed ID: 15376728
[TBL] [Abstract][Full Text] [Related]
19. The wear of metal-on-metal total hip prostheses measured in a hip simulator.
Scholes SC; Green SM; Unsworth A
Proc Inst Mech Eng H; 2001; 215(6):523-30. PubMed ID: 11848384
[TBL] [Abstract][Full Text] [Related]
20. A Novel Technique for Assessing Antioxidant Concentration in Retrieved UHMWPE.
Currier BH; Van Citters DW
Clin Orthop Relat Res; 2017 May; 475(5):1356-1365. PubMed ID: 27334326
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]