These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 27345704)

  • 21. Tribological assessment of a flexible carbon-fibre-reinforced poly(ether-ether-ketone) acetabular cup articulating against an alumina femoral head.
    Scholes SC; Inman IA; Unsworth A; Jones E
    Proc Inst Mech Eng H; 2008 Apr; 222(3):273-83. PubMed ID: 18491697
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Wear products of total hip arthroplasty: The case of polyethylene.
    Massin P; Achour S
    Morphologie; 2017 Mar; 101(332):1-8. PubMed ID: 27426252
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Explant analysis of a Maestro™ wrist prosthesis and calculation of its lubrication regime.
    Kandemir G; Smith S; Schmidt I; Joyce TJ
    J Mech Behav Biomed Mater; 2020 Oct; 110():103933. PubMed ID: 32957227
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Distribution of polyethylene wear particles and bone fragments in periprosthetic tissue around total hip joint replacements.
    Zolotarevova E; Entlicher G; Pavlova E; Slouf M; Pokorny D; Vesely F; Gallo J; Sosna A
    Acta Biomater; 2010 Sep; 6(9):3595-600. PubMed ID: 20417318
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Tribological characteristics of polyethylene glycol (PEG) as a lubricant for wear resistance of ultra-high-molecular-weight polyethylene (UHMWPE ) in artificial knee join.
    Kobayashi M; Koide T; Hyon SH
    J Mech Behav Biomed Mater; 2014 Oct; 38():33-8. PubMed ID: 25016174
    [TBL] [Abstract][Full Text] [Related]  

  • 26. In vitro wear performance of standard, crosslinked, and vitamin-E-blended UHMWPE.
    Affatato S; Bracco P; Costa L; Villa T; Quaglini V; Toni A
    J Biomed Mater Res A; 2012 Mar; 100(3):554-60. PubMed ID: 22162269
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The adsorption and lubrication behavior of synovial fluid proteins and glycoproteins on the bearing-surface materials of hip replacements.
    Roba M; Naka M; Gautier E; Spencer ND; Crockett R
    Biomaterials; 2009 Apr; 30(11):2072-8. PubMed ID: 19155063
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Friction, lubrication, and polymer transfer between UHMWPE and CoCrMo hip-implant materials: a fluorescence microscopy study.
    Crockett R; Roba M; Naka M; Gasser B; Delfosse D; Frauchiger V; Spencer ND
    J Biomed Mater Res A; 2009 Jun; 89(4):1011-8. PubMed ID: 18478550
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Oxidation-induced dynamic changes in morphology reflected on freeze-fractured surface of gamma-irradiated ultra-high molecular weight polyethylene components.
    Watanabe E; Suzuki M; Nagata K; Kaneeda T; Harada Y; Utsumi M; Mori A; Moriya H
    J Biomed Mater Res; 2002 Dec; 62(4):540-9. PubMed ID: 12221702
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Physicochemical and biomechanical examination of surfaces of retrieved polyethylene heads from total hip prostheses with rotating polyethylene head system.
    Katayama K; Maezawa H; Uesato N; Sasada T
    J Orthop Sci; 2001; 6(6):503-9. PubMed ID: 11793172
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A simple fully integrated contact-coupled wear prediction for ultra-high molecular weight polyethylene hip implants.
    Kang L; Galvin AL; Jin ZM; Fisher J
    Proc Inst Mech Eng H; 2006 Jan; 220(1):33-46. PubMed ID: 16459444
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A new formulation for the prediction of polyethylene wear in artificial hip joints.
    Liu F; Galvin A; Jin Z; Fisher J
    Proc Inst Mech Eng H; 2011 Jan; 225(1):16-24. PubMed ID: 21381484
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Five-year comparison of wear using oxidised zirconium and cobalt-chrome femoral heads in total hip arthroplasty: a multicentre randomised controlled trial.
    Jassim SS; Patel S; Wardle N; Tahmassebi J; Middleton R; Shardlow DL; Stephen A; Hutchinson J; Haddad FS
    Bone Joint J; 2015 Jul; 97-B(7):883-9. PubMed ID: 26130341
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements.
    Smith SL; Dowson D; Goldsmith AA
    Proc Inst Mech Eng H; 2001; 215(2):161-70. PubMed ID: 11382075
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations.
    Galvin AL; Tipper JL; Jennings LM; Stone MH; Jin ZM; Ingham E; Fisher I
    Proc Inst Mech Eng H; 2007 Jan; 221(1):1-10. PubMed ID: 17315763
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus.
    Jin ZM; Dowson D; Fisher J
    Proc Inst Mech Eng H; 1997; 211(3):247-56. PubMed ID: 9256001
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Metal-on-metal bearings surfaces: materials, manufacture, design, optimization, and alternatives.
    Isaac GH; Thompson J; Williams S; Fisher J
    Proc Inst Mech Eng H; 2006 Feb; 220(2):119-33. PubMed ID: 16669381
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Deconvolution of surface topology for quantification of initial wear in highly cross-linked acetabular components for THA.
    Kurtz SM; Turner JL; Herr M; Edidin AA
    J Biomed Mater Res; 2002; 63(5):492-500. PubMed ID: 12209892
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Biological reactions to wear debris in total joint replacement.
    Ingham E; Fisher J
    Proc Inst Mech Eng H; 2000; 214(1):21-37. PubMed ID: 10718048
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Synthesis and characterization of a novel UHMWPE interpenetrating polymer network.
    Beauregard GP; James SP
    Biomed Sci Instrum; 1999; 35():415-9. PubMed ID: 11143388
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.