These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 27347615)

  • 1. Renewed interest in the significance of the tall R wave in ECG lead V1 during right ventricular pacing.
    Barold SS; Giudici MC
    Expert Rev Med Devices; 2016 Jul; 13(7):611-3. PubMed ID: 27347615
    [No Abstract]   [Full Text] [Related]  

  • 2. Electrocardiographic algorithms to predict true right ventricular pacing in the presence of right bundle branch block-like pattern.
    Almehairi M; Ali FS; Enriquez A; Michael K; Redfearn D; Abdollah H; Simpson C; Chiale PA; Baranchuk A
    Int J Cardiol; 2014 Apr; 172(3):e403-5. PubMed ID: 24439865
    [No Abstract]   [Full Text] [Related]  

  • 3. Right Bundle Branch Block-Like Pattern During Ventricular Pacing: A Surface Electrocardiographic Mapping Technique to Locate the Ventricular Lead.
    Almehairi M; Enriquez A; Redfearn D; Michael K; Abdollah H; Alfagih A; Nolan R; Baranchuk A; Simpson CS
    Can J Cardiol; 2015 Aug; 31(8):1019-24. PubMed ID: 26118446
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The fusion band in V1: a simple ECG guide to optimal resynchronization? An echocardiographic case report.
    Gianfranchi L; Bettiol K; Pacchioni F; Corbucci G; Alboni P
    Cardiovasc Ultrasound; 2005 Sep; 3():29. PubMed ID: 16168058
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Safe right bundle branch block pattern during permanent right ventricular pacing: a case report.
    Errahmouni A; Charniot JC; Artigou JY
    Turk Kardiyol Dern Ars; 2013 Sep; 41(6):522-5. PubMed ID: 24104978
    [TBL] [Abstract][Full Text] [Related]  

  • 6. RV-only pacing can produce a Q wave in lead 1 and an R wave in V1: implications for biventricular pacing.
    Cooper JM; Patel RK; Emmi A; Wang Y; Kirkpatrick JN
    Pacing Clin Electrophysiol; 2014 May; 37(5):585-90. PubMed ID: 24372196
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Right ventricular enlargement mimicking electrocardiographic left ventricular pacing.
    Hemminger EJ; Criley JM
    J Electrocardiol; 2006 Apr; 39(2):180-2. PubMed ID: 16580416
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of left ventricular dyssynchrony in pacing-induced left bundle branch block compared with intrinsic left bundle branch block.
    Ghani A; Delnoy PP; Ottervanger JP; Ramdat Misier AR; Smit JJ; Elvan A
    Europace; 2011 Oct; 13(10):1504-7. PubMed ID: 21527389
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of left ventricular torsion and strain with biventricular pacing in patients with underlying right bundle branch block versus those with left bundle branch block.
    De S; Popović ZB; Verhaert D; Dresing T; Wilkoff B; Starling R; Tang WH; Thomas JD; Grimm RA
    Am J Cardiol; 2015 Apr; 115(7):918-23. PubMed ID: 25779616
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An electrocardiographic algorithm for determining the location of pacemaker electrode in patients with right bundle branch block configuration during permanent ventricular pacing.
    Okmen E; Erdinler I; Oguz E; Akyol A; Turek O; Cam N; Ulufer T
    Angiology; 2006; 57(5):623-30. PubMed ID: 17067986
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bifocal right ventricular pacing: bail-out or cop-out?
    Wedam EF; Haigney MC
    Cardiol J; 2010; 17(1):1-3. PubMed ID: 20104450
    [No Abstract]   [Full Text] [Related]  

  • 12. Electrocardiographic features of ventricular pacing lead in the middle cardiac vein vs. right ventricular apex in a patient with persistent left superior vena cava.
    Chen TE; Wang CC; Satish OS; Wu D
    J Electrocardiol; 2007; 40(6):531-3. PubMed ID: 17673250
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ventricular activation onset-triggered left ventricular pacing: safety and feasibility in initial clinical experience.
    Wong GK; Florendo FT; Cohen FM
    Pacing Clin Electrophysiol; 2004 Jun; 27(6 Pt 1):730-9. PubMed ID: 15189527
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Analysis of the electrocardiographic waveforms produced by right ventricular pacing: relation to the nonpaced patterns.
    Friedman HS
    Pacing Clin Electrophysiol; 2008 May; 31(5):529-35. PubMed ID: 18439164
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electrocardiographic characteristics of repetitive monomorphic right ventricular tachycardia originating near the His-bundle.
    Yamauchi Y; Aonuma K; Takahashi A; Sekiguchi Y; Hachiya H; Yokoyama Y; Kumagai K; Nogami A; Iesaka Y; Isobe M
    J Cardiovasc Electrophysiol; 2005 Oct; 16(10):1041-8. PubMed ID: 16191113
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reinitiation of ventricular macroreentry within the His-Purkinje system by back-up ventricular pacing - a mechanism of ventricular tachycardia storm.
    Reithmann C; Hahnefeld A; Oversohl N; Ulbrich M; Remp T; Steinbeck G
    Pacing Clin Electrophysiol; 2007 Feb; 30(2):225-35. PubMed ID: 17338720
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Safety and efficiency of pacing at right ventricular outflow versus at ventricular cardiac apex].
    Deng XQ; Cai L; Tang J; Liu HX; Liu JX; He C; Yan CB
    Zhonghua Xin Xue Guan Bing Za Zhi; 2008 Aug; 36(8):726-8. PubMed ID: 19100116
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Right ventricular outflow tract pacing: radiographic and electrocardiographic correlates of lead position.
    McGavigan AD; Roberts-Thomson KC; Hillock RJ; Stevenson IH; Mond HG
    Pacing Clin Electrophysiol; 2006 Oct; 29(10):1063-8. PubMed ID: 17038137
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Electrical and mechanical components of dyssynchrony in heart failure patients with normal QRS duration and left bundle-branch block: impact of left and biventricular pacing.
    Turner MS; Bleasdale RA; Vinereanu D; Mumford CE; Paul V; Fraser AG; Frenneaux MP
    Circulation; 2004 Jun; 109(21):2544-9. PubMed ID: 15148267
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electrocardiographic characteristics in right ventricular vs biventricular pacing in patients with paced right bundle-branch block QRS pattern.
    Refaat M; Mansour M; Singh JP; Ruskin J; Heist EK
    J Electrocardiol; 2011; 44(2):289-95. PubMed ID: 20888007
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.