BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 2735246)

  • 1. [Clinical studies of a new non-ionic contrast medium--iohexol (Omnipaque)--in patients sensitive to ionic contrast medium].
    Fuse H; Miyazaki K; Nakasima T; Fujita Y
    Hinyokika Kiyo; 1989 Feb; 35(2):371-5. PubMed ID: 2735246
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Adverse reactions following two separate intravascular injections of contrast media in the same patient. A comparison between iohexol and monomeric ionic media.
    Sogn EE; Odegård T; Haider T; Andrew E
    Acta Radiol; 1987; 28(1):93-7. PubMed ID: 2952151
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Plain abdominal film after contrast-enhanced CT; re-evaluation by using iohexol].
    Ishii C; Toyoda K; Tada S
    Rinsho Hoshasen; 1989 May; 34(5):599-604. PubMed ID: 2746956
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Contrast media in abdominal computed tomography. A double blind clinical trial comparing a non-ionic (iohexol) and an ionic (metrizoate) contrast medium.
    Skalpe IO; Ostensen HM
    Eur J Radiol; 1984 Feb; 4(1):74-5. PubMed ID: 6373261
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Effects of ionic and non-ionic roentgen-contrast media upon ex vivo hemostasis in rabbits].
    Klimanova EV; Petrukhina GN; Makarov VA; Sergeev PV; Bolotova EN; Shimanovskiĭ NL
    Eksp Klin Farmakol; 2006; 69(1):60-4. PubMed ID: 16579063
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Examination by densitometer on visualization of non-ionic contrast medium (iohexol) in excretory urography. 1. Visualization by bolus injection].
    Ikeuchi T; Hamashima T; Sakamoto M
    Hinyokika Kiyo; 1990 Feb; 36(2):131-6. PubMed ID: 2343806
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A double-blind study comparing the efficiency, tolerance and renal effects of iopromide and iopamidol.
    Kennedy C; Rickards D; Lee S; Sharp MB; Dawson P
    Br J Radiol; 1988 Apr; 61(724):288-93. PubMed ID: 3285943
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Frequency of late allergy-like adverse reactions following injection of intravascular non-ionic contrast media. A retrospective study comparing a non-ionic monomeric contrast medium with a non-ionic dimeric contrast medium.
    Rydberg J; Charles J; Aspelin P
    Acta Radiol; 1998 May; 39(3):219-22. PubMed ID: 9571932
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Examination by densitometer on visualization of non-ionic contrast medium (iohexol) in excretory urography. 2. Changes in visualization by DIP].
    Ikeuchi T; Hamashima T; Sakamoto M
    Hinyokika Kiyo; 1990 Feb; 36(2):137-41. PubMed ID: 2343807
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Comparative study on nephrotoxicity of ionic and non-ionic contrast agents for drip infused urography].
    Sugaya K; Nishizawa O; Noto H; Suzuki T; Shimoda N; Miyagata S; Harada T; Tsuchida S
    Hinyokika Kiyo; 1992 Jul; 38(7):767-73. PubMed ID: 1524001
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Nephrotoxicity of ionic and nonionic contrast media in selective renovasography].
    Porst H; Mayer R; Clauss W
    Urologe A; 1986 Mar; 25(2):120-3. PubMed ID: 3521047
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Lumbar myelography with iohexol. Adverse effects compared with spinal puncture.
    Nestvold K; Sortland O
    Acta Radiol; 1988; 29(6):637-40. PubMed ID: 3190941
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Late adverse reactions of non-ionic intravenous contrast media].
    Nambu T; Yoshikawa H; Shirato H; Suzuki K
    Nihon Igaku Hoshasen Gakkai Zasshi; 1990 Aug; 50(8):1019-21. PubMed ID: 2235336
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Experimental and clinical studies of non-ionic isoosmolality contrast medium (iohexol 140)--II. IADSA in clinical practice].
    Tajima N
    Nihon Igaku Hoshasen Gakkai Zasshi; 1986 Apr; 46(4):541-52. PubMed ID: 3532027
    [No Abstract]   [Full Text] [Related]  

  • 15. Fixed drug eruption associated with intravenous contrast media: report in a woman receiving iohexol.
    Wright NA; Cohen PR
    J Drugs Dermatol; 2011 Jul; 10(7):802-4. PubMed ID: 21720665
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Iohexol does not influence the levels of blood serum cation electrolytes during intravenous pyelography.
    Kokkas B; Mironidou M; Katsimba D; Kaitatzis C; Karamanos G; Christopoulos S
    Radiol Med; 2001 Jun; 101(6):485-7. PubMed ID: 11479446
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Iohexol and ioxaglate in peripheral angiography.
    Stiris MG; Laerum F
    Acta Radiol; 1987; 28(6):767-70. PubMed ID: 2962617
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Water-soluble contrast media in radiography of small bowel obstruction. Comparison of ionic and non-ionic contrast media.
    Stordahl A; Laerum F; Gjølberg T; Enge I
    Acta Radiol; 1988; 29(1):53-6. PubMed ID: 2964845
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Myelography with Omnipaque (Iohexol) using basic radiographic facilities: the main adverse effects.
    Ndosi BN; Ndosi NK; Kazema RR
    Cent Afr J Med; 1996 Jul; 42(7):192-5. PubMed ID: 8936782
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of patient reactions and diagnostic quality for hysterosalpingography using ionic and nonionic contrast media.
    Chen MY; Zagoria RJ; Fayez JA; Ott DJ; Van Swearingen FL
    Acad Radiol; 1995 Feb; 2(2):123-7. PubMed ID: 9419535
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.