BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 27353849)

  • 1. A comparison of the Cook-Swartz Doppler with conventional clinical methods for free flap monitoring: A systematic review and a meta-analysis.
    Han ZF; Guo LL; Liu LB; Li Q; Zhou J; Wei AZ; Guo PF
    Int J Surg; 2016 Aug; 32():109-15. PubMed ID: 27353849
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Implantable Cook-Swartz Doppler probe versus Synovis Flow Coupler for the post-operative monitoring of free flap breast reconstruction.
    Um GT; Chang J; Louie O; Colohan SM; Said HK; Neligan PC; Mathes DW
    J Plast Reconstr Aesthet Surg; 2014 Jul; 67(7):960-6. PubMed ID: 24767693
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The implantable Cook-Swartz Doppler probe for postoperative monitoring in head and neck free flap reconstruction.
    Guillemaud JP; Seikaly H; Cote D; Allen H; Harris JR
    Arch Otolaryngol Head Neck Surg; 2008 Jul; 134(7):729-34. PubMed ID: 18645123
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Direct comparison of postoperative monitoring of free flaps with microdialysis, implantable cook-swartz Doppler probe, and clinical monitoring in 20 consecutive patients.
    Frost MW; Niumsawatt V; Rozen WM; Eschen GE; Damsgaard TE; Kiil BJ
    Microsurgery; 2015 May; 35(4):262-71. PubMed ID: 25285732
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Postoperative monitoring of lower limb free flaps with the Cook-Swartz implantable Doppler probe: A clinical trial.
    Rozen WM; Enajat M; Whitaker IS; Lindkvist U; Audolfsson T; Acosta R
    Microsurgery; 2010 Jul; 30(5):354-60. PubMed ID: 19967762
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The efficacy of the Cook-Swartz implantable Doppler in the detection of free-flap compromise: a systematic review protocol.
    Agha RA; Gundogan B; Fowler AJ; Bragg TW; Orgill DP
    BMJ Open; 2014 Mar; 4(3):e004253. PubMed ID: 24622948
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Retrospective evaluation of diagnostic accuracy of free flap monitoring with the Cook-Swartz-Doppler probe in head and neck reconstruction.
    Leibig N; Ha-Phuoc A; Stark GB; Schmelzeisen R; Metzger MC; Eisenhardt SU; Voss PJ
    J Craniomaxillofac Surg; 2019 Dec; 47(12):1973-1979. PubMed ID: 31810844
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Rationale for the use of the implantable Doppler probe based on 7 years' experience.
    Ho MW; Cassidy C; Brown JS; Shaw RJ; Bekiroglu F; Rogers SN
    Br J Oral Maxillofac Surg; 2014 Jul; 52(6):530-4. PubMed ID: 24721166
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A chimaeric-pattern flap design for implantable Doppler surrogate monitoring: a novel placement technique.
    Kim JT; Ho SY; Kim YH
    J Plast Reconstr Aesthet Surg; 2014 Feb; 67(2):190-7. PubMed ID: 24365566
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The efficacy of postoperative monitoring: a single surgeon comparison of clinical monitoring and the implantable Doppler probe in 547 consecutive free flaps.
    Rozen WM; Chubb D; Whitaker IS; Acosta R
    Microsurgery; 2010; 30(2):105-10. PubMed ID: 19790183
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Implantable Doppler Removal After Free Flap Monitoring Among Head and Neck Microvascular Surgeons.
    Ong AA; Ducic Y; Pipkorn P; Wax MK
    Laryngoscope; 2022 Mar; 132(3):554-559. PubMed ID: 34363218
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of the Implantable Doppler Probe for Free Flap Monitoring in Lower Limb Reconstruction.
    Lenz Y; Gross R; Penna V; Bannasch H; Stark GB; Eisenhardt SU
    J Reconstr Microsurg; 2018 Mar; 34(3):218-226. PubMed ID: 29179224
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Adjunctive technologies in postoperative free-flap monitoring: a systematic review.
    Lacey H; Kanakopoulos D; Hussein S; Moyasser O; Ward J; King ICC
    J Plast Reconstr Aesthet Surg; 2023 Dec; 87():147-155. PubMed ID: 37844383
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Postoperative monitoring of free flaps in autologous breast reconstruction: a multicenter comparison of 398 flaps using clinical monitoring, microdialysis, and the implantable Doppler probe.
    Whitaker IS; Rozen WM; Chubb D; Acosta R; Kiil BJ; Birke-Sorensen H; Grinsell D; Ashton MW
    J Reconstr Microsurg; 2010 Aug; 26(6):409-16. PubMed ID: 20221988
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Cook-Swartz venous Doppler probe for the post-operative monitoring of free tissue transfers in the United Kingdom: a preliminary report.
    Oliver DW; Whitaker IS; Giele H; Critchley P; Cassell O
    Br J Plast Surg; 2005 Apr; 58(3):366-70. PubMed ID: 15780232
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Introduction of the implantable Doppler system did not lead to an increased salvage rate of compromised flaps: a multivariate analysis.
    Smit JM; Werker PMN; Liss AG; Enajat M; de Bock GH; Audolfsson T; Acosta R
    Plast Reconstr Surg; 2010 Jun; 125(6):1710-1717. PubMed ID: 20517095
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Deciphering the Sensitivity and Specificity of the Implantable Doppler Probe in Free Flap Monitoring.
    Chang EI; Ibrahim A; Zhang H; Liu J; Nguyen AT; Reece GP; Yu P
    Plast Reconstr Surg; 2016 Mar; 137(3):971-976. PubMed ID: 26910681
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Current evidence for postoperative monitoring of microvascular free flaps: a systematic review.
    Chae MP; Rozen WM; Whitaker IS; Chubb D; Grinsell D; Ashton MW; Hunter-Smith DJ; Lineaweaver WC
    Ann Plast Surg; 2015 May; 74(5):621-32. PubMed ID: 23038130
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of arterial and venous implantable Doppler postoperative monitoring of free flaps: Systematic review and meta-analysis of diagnostic test accuracy.
    Klifto KM; Milek D; Gurno CF; Seal SM; Hultman CS; Rosson GD; Cooney DS
    Microsurgery; 2020 May; 40(4):501-511. PubMed ID: 32031735
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Implantable Doppler flow system: experience with 24 microvascular free-flap operations.
    Pryor SG; Moore EJ; Kasperbauer JL
    Otolaryngol Head Neck Surg; 2006 Nov; 135(5):714-8. PubMed ID: 17071300
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.