These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

388 related articles for article (PubMed ID: 27364997)

  • 1. Coming of age: the artificial pancreas for type 1 diabetes.
    Thabit H; Hovorka R
    Diabetologia; 2016 Sep; 59(9):1795-805. PubMed ID: 27364997
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Is an artificial pancreas (closed-loop system) for Type 1 diabetes effective?
    Boughton CK; Hovorka R
    Diabet Med; 2019 Mar; 36(3):279-286. PubMed ID: 30183096
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Insulin delivery and nocturnal glucose control in children and adolescents with type 1 diabetes.
    Tauschmann M; Hovorka R
    Expert Opin Drug Deliv; 2017 Dec; 14(12):1367-1377. PubMed ID: 28819992
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Glucose-responsive insulin and glucagon delivery (dual-hormone artificial pancreas) in adults with type 1 diabetes: a randomized crossover controlled trial.
    Haidar A; Legault L; Dallaire M; Alkhateeb A; Coriati A; Messier V; Cheng P; Millette M; Boulet B; Rabasa-Lhoret R
    CMAJ; 2013 Mar; 185(4):297-305. PubMed ID: 23359039
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Automated hybrid closed-loop control with a proportional-integral-derivative based system in adolescents and adults with type 1 diabetes: individualizing settings for optimal performance.
    Ly TT; Weinzimer SA; Maahs DM; Sherr JL; Roy A; Grosman B; Cantwell M; Kurtz N; Carria L; Messer L; von Eyben R; Buckingham BA
    Pediatr Diabetes; 2017 Aug; 18(5):348-355. PubMed ID: 27191182
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Day-and-Night Hybrid Closed-Loop Insulin Delivery in Adolescents With Type 1 Diabetes: A Free-Living, Randomized Clinical Trial.
    Tauschmann M; Allen JM; Wilinska ME; Thabit H; Stewart Z; Cheng P; Kollman C; Acerini CL; Dunger DB; Hovorka R
    Diabetes Care; 2016 Jul; 39(7):1168-74. PubMed ID: 26740634
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assessing the efficacy, safety and utility of 6-month day-and-night automated closed-loop insulin delivery under free-living conditions compared with insulin pump therapy in children and adolescents with type 1 diabetes: an open-label, multicentre, multinational, single-period, randomised, parallel group study protocol.
    Musolino G; Allen JM; Hartnell S; Wilinska ME; Tauschmann M; Boughton C; Campbell F; Denvir L; Trevelyan N; Wadwa P; DiMeglio L; Buckingham BA; Weinzimer S; Acerini CL; Hood K; Fox S; Kollman C; Sibayan J; Borgman S; Cheng P; Hovorka R
    BMJ Open; 2019 Jun; 9(6):e027856. PubMed ID: 31164368
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Glucose-responsive insulin delivery for type 1 diabetes: The artificial pancreas story.
    Bally L; Thabit H; Hovorka R
    Int J Pharm; 2018 Jun; 544(2):309-318. PubMed ID: 29258910
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Closing the Loop on Exercise in Type 1 Diabetes.
    Bally L; Thabit H
    Curr Diabetes Rev; 2018; 14(3):257-265. PubMed ID: 28245784
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Unsupervised overnight closed loop insulin delivery during free living: analysis of randomised cross-over home studies in adults and adolescents with type 1 diabetes.
    Thabit H; Elleri D; Leelarathna L; Allen J; Lubina-Solomon A; Stadler M; Walkinshaw E; Iqbal A; Choudhary P; Wilinska M; Barnard K; Heller S; Amiel S; Evans M; Dunger D; Hovorka R
    Lancet; 2015 Feb; 385 Suppl 1():S96. PubMed ID: 26312919
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bringing closed-loop home: recent advances in closed-loop insulin delivery.
    Thabit H; Hovorka R
    Curr Opin Endocrinol Diabetes Obes; 2014 Apr; 21(2):95-101. PubMed ID: 24569550
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [What is the current state of the artificial pancreas in diabetes care?].
    Dimou M; Laimer M; Stettler C; Bally L
    Internist (Berl); 2020 Jan; 61(1):102-109. PubMed ID: 31863132
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Insulin pump therapy in youth with type 1 diabetes: toward closed-loop systems.
    Tauschmann M; Hovorka R
    Expert Opin Drug Deliv; 2014 Jun; 11(6):943-55. PubMed ID: 24749563
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Overnight closed loop insulin delivery (artificial pancreas) in adults with type 1 diabetes: crossover randomised controlled studies.
    Hovorka R; Kumareswaran K; Harris J; Allen JM; Elleri D; Xing D; Kollman C; Nodale M; Murphy HR; Dunger DB; Amiel SA; Heller SR; Wilinska ME; Evans ML
    BMJ; 2011 Apr; 342():d1855. PubMed ID: 21493665
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison Between Closed-Loop Insulin Delivery System (the Artificial Pancreas) and Sensor-Augmented Pump Therapy: A Randomized-Controlled Crossover Trial.
    Haidar A; Legault L; Raffray M; Gouchie-Provencher N; Jacobs PG; El-Fathi A; Rutkowski J; Messier V; Rabasa-Lhoret R
    Diabetes Technol Ther; 2021 Mar; 23(3):168-174. PubMed ID: 33050728
    [No Abstract]   [Full Text] [Related]  

  • 16. Overnight closed-loop insulin delivery with model predictive control: assessment of hypoglycemia and hyperglycemia risk using simulation studies.
    Wilinska ME; Budiman ES; Taub MB; Elleri D; Allen JM; Acerini CL; Dunger DB; Hovorka R
    J Diabetes Sci Technol; 2009 Sep; 3(5):1109-20. PubMed ID: 20144424
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hypoglycaemia incidence and recovery during home use of hybrid closed-loop insulin delivery in adults with type 1 diabetes.
    Ruan Y; Bally L; Thabit H; Leelarathna L; Hartnell S; Tauschmann M; Wilinska ME; Evans ML; Mader JK; Kojzar H; Dellweg S; Benesch C; Arnolds S; Pieber TR; Hovorka R
    Diabetes Obes Metab; 2018 Aug; 20(8):2004-2008. PubMed ID: 29577536
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Closed-loop systems - Update 2020].
    Melmer A; Tripyla A; Herzig D; Laimer M; Stettler C; Bally L
    Ther Umsch; 2020 Sep; 77(7):312-318. PubMed ID: 32996429
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The International Diabetes Closed-Loop Study: Testing Artificial Pancreas Component Interoperability.
    Anderson SM; Dassau E; Raghinaru D; Lum J; Brown SA; Pinsker JE; Church MM; Levy C; Lam D; Kudva YC; Buckingham B; Forlenza GP; Wadwa RP; Laffel L; Doyle FJ; DeVries JH; Renard E; Cobelli C; Boscari F; Del Favero S; Kovatchev BP
    Diabetes Technol Ther; 2019 Feb; 21(2):73-80. PubMed ID: 30649925
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system.
    Hanazaki K; Munekage M; Kitagawa H; Yatabe T; Munekage E; Shiga M; Maeda H; Namikawa T
    J Artif Organs; 2016 Sep; 19(3):209-18. PubMed ID: 27142278
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.