These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 27365220)

  • 21. High-resolution characterization of antibody fragment/antigen interactions using Biacore T100.
    Papalia GA; Baer M; Luehrsen K; Nordin H; Flynn P; Myszka DG
    Anal Biochem; 2006 Dec; 359(1):112-9. PubMed ID: 17027901
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Kinetic screening of antibody-Im7 conjugates by capture on a colicin E7 DNase domain using optical biosensors.
    Hosse RJ; Tay L; Hattarki MK; Pontes-Braz L; Pearce LA; Nuttall SD; Dolezal O
    Anal Biochem; 2009 Feb; 385(2):346-57. PubMed ID: 19073134
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Screening antibody-antigen interactions in parallel using Biacore A100.
    Säfsten P; Klakamp SL; Drake AW; Karlsson R; Myszka DG
    Anal Biochem; 2006 Jun; 353(2):181-90. PubMed ID: 16510107
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of biosensor platforms for surface plasmon resonance based detection of paralytic shellfish toxins.
    Haughey SA; Campbell K; Yakes BJ; Prezioso SM; Degrasse SL; Kawatsu K; Elliott CT
    Talanta; 2011 Jul; 85(1):519-26. PubMed ID: 21645735
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Kinetic screening of antibodies from crude hybridoma samples using Biacore.
    Canziani GA; Klakamp S; Myszka DG
    Anal Biochem; 2004 Feb; 325(2):301-7. PubMed ID: 14751265
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Understanding ForteBio's Sensors for High-Throughput Kinetic and Epitope Screening for Purified Antibodies and Yeast Culture Supernatant.
    Yu Y; Mitchell S; Lynaugh H; Brown M; Nobrega RP; Zhi X; Sun T; Caffry I; Cao Y; Yang R; Burnina I; Xu Y; Estep P
    J Biomol Screen; 2016 Jan; 21(1):88-95. PubMed ID: 26442912
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Colloidal gold conjugated monoclonal antibodies, studied in the BIAcore biosensor and in the Nycocard immunoassay format.
    Johne B; Hansen K; Mørk E; Holtlund J
    J Immunol Methods; 1995 Jun; 183(1):167-74. PubMed ID: 7602134
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Exploring the dynamic range of the kinetic exclusion assay in characterizing antigen-antibody interactions.
    Bee C; Abdiche YN; Stone DM; Collier S; Lindquist KC; Pinkerton AC; Pons J; Rajpal A
    PLoS One; 2012; 7(4):e36261. PubMed ID: 22558410
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Kinetic analysis of a protein antigen-antibody interaction limited by mass transport on an optical biosensor.
    Myszka DG; Morton TA; Doyle ML; Chaiken IM
    Biophys Chem; 1997 Feb; 64(1-3):127-37. PubMed ID: 9127943
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A global benchmark study using affinity-based biosensors.
    Rich RL; Papalia GA; Flynn PJ; Furneisen J; Quinn J; Klein JS; Katsamba PS; Waddell MB; Scott M; Thompson J; Berlier J; Corry S; Baltzinger M; Zeder-Lutz G; Schoenemann A; Clabbers A; Wieckowski S; Murphy MM; Page P; Ryan TE; Duffner J; Ganguly T; Corbin J; Gautam S; Anderluh G; Bavdek A; Reichmann D; Yadav SP; Hommema E; Pol E; Drake A; Klakamp S; Chapman T; Kernaghan D; Miller K; Schuman J; Lindquist K; Herlihy K; Murphy MB; Bohnsack R; Andrien B; Brandani P; Terwey D; Millican R; Darling RJ; Wang L; Carter Q; Dotzlaf J; Lopez-Sagaseta J; Campbell I; Torreri P; Hoos S; England P; Liu Y; Abdiche Y; Malashock D; Pinkerton A; Wong M; Lafer E; Hinck C; Thompson K; Primo CD; Joyce A; Brooks J; Torta F; Bagge Hagel AB; Krarup J; Pass J; Ferreira M; Shikov S; Mikolajczyk M; Abe Y; Barbato G; Giannetti AM; Krishnamoorthy G; Beusink B; Satpaev D; Tsang T; Fang E; Partridge J; Brohawn S; Horn J; Pritsch O; Obal G; Nilapwar S; Busby B; Gutierrez-Sanchez G; Gupta RD; Canepa S; Witte K; Nikolovska-Coleska Z; Cho YH; D'Agata R; Schlick K; Calvert R; Munoz EM; Hernaiz MJ; Bravman T; Dines M; Yang MH; Puskas A; Boni E; Li J; Wear M; Grinberg A; Baardsnes J; Dolezal O; Gainey M; Anderson H; Peng J; Lewis M; Spies P; Trinh Q; Bibikov S; Raymond J; Yousef M; Chandrasekaran V; Feng Y; Emerick A; Mundodo S; Guimaraes R; McGirr K; Li YJ; Hughes H; Mantz H; Skrabana R; Witmer M; Ballard J; Martin L; Skladal P; Korza G; Laird-Offringa I; Lee CS; Khadir A; Podlaski F; Neuner P; Rothacker J; Rafique A; Dankbar N; Kainz P; Gedig E; Vuyisich M; Boozer C; Ly N; Toews M; Uren A; Kalyuzhniy O; Lewis K; Chomey E; Pak BJ; Myszka DG
    Anal Biochem; 2009 Mar; 386(2):194-216. PubMed ID: 19133223
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Transport and kinetic processes underlying biomolecular interactions in the BIACORE optical biosensor.
    Sikavitsas V; Nitsche JM; Mountziaris TJ
    Biotechnol Prog; 2002; 18(4):885-97. PubMed ID: 12153326
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Long term kinetic measurements revealing precision and general performance of surface plasmon resonance biosensors.
    Steinicke F; Oltmann-Norden I; Wätzig H
    Anal Biochem; 2017 Aug; 530():94-103. PubMed ID: 28501475
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Analysis of the binding of the Fab fragment of monoclonal antibody NC10 to influenza virus N9 neuraminidase from tern and whale using the BIAcore biosensor: effect of immobilization level and flow rate on kinetic analysis.
    Kortt AA; Nice E; Gruen LC
    Anal Biochem; 1999 Aug; 273(1):133-41. PubMed ID: 10452809
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Biacore surface matrix effects on the binding kinetics and affinity of an antigen/antibody complex.
    Drake AW; Tang ML; Papalia GA; Landes G; Haak-Frendscho M; Klakamp SL
    Anal Biochem; 2012 Oct; 429(1):58-69. PubMed ID: 22766435
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Interpreting kinetic rate constants from optical biosensor data recorded on a decaying surface.
    Joss L; Morton TA; Doyle ML; Myszka DG
    Anal Biochem; 1998 Aug; 261(2):203-10. PubMed ID: 9716423
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Analysis of human chorionic gonadotropin-monoclonal antibody interaction in BIAcore.
    Ashish B; Murthy GS
    J Biosci; 2004 Mar; 29(1):57-66. PubMed ID: 15286404
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Biosensor analysis of antigen-antibody interactions as a priority step in the generation of monoclonal bispecific antibodies.
    Horenstein A; Poiesi C; Camagna M; de Monte L; Mariani M; Albertini A; Malavasi F
    Cell Biophys; 1994; 24-25():109-17. PubMed ID: 7736514
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Analysis of binding of monoclonal antibody to a malarial peptide by surface plasmon resonance biosensor and integrated rate equations.
    Wohlhueter RM; Parekh K; Udhayakumar V; Fang S; Lal AA
    J Immunol; 1994 Jul; 153(1):181-9. PubMed ID: 8207235
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Analyzing a kinetic titration series using affinity biosensors.
    Karlsson R; Katsamba PS; Nordin H; Pol E; Myszka DG
    Anal Biochem; 2006 Feb; 349(1):136-47. PubMed ID: 16337141
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Use of biosensors to characterize recombinant proteins.
    Van Regenmortel MH
    Dev Biol Stand; 1994; 83():143-51. PubMed ID: 7883088
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.