These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 27369636)

  • 1. Biomechanical effects of morphological variations of the cortical wall at the bone-cement interface.
    Zhang CL; Shen GQ; Zhu KP; Liu DX
    J Orthop Surg Res; 2016 Jul; 11(1):72. PubMed ID: 27369636
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Micro-mechanical modeling of the cement-bone interface: the effect of friction, morphology and material properties on the micromechanical response.
    Janssen D; Mann KA; Verdonschot N
    J Biomech; 2008 Nov; 41(15):3158-63. PubMed ID: 18848699
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The mechanical effects of different levels of cement penetration at the cement-bone interface.
    Waanders D; Janssen D; Mann KA; Verdonschot N
    J Biomech; 2010 Apr; 43(6):1167-75. PubMed ID: 20022010
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Study on the effect of bone-cement interface with bone cement oscillator].
    Wang Y; Yan F; Song DC; Qu YL; Yang GF; Shi ZW; Gu WG; Song YB; Li DB; Wang CL
    Zhonghua Wai Ke Za Zhi; 2008 Mar; 46(6):431-3. PubMed ID: 18785577
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Finite element simulation of cement-bone interface micromechanics: a comparison to experimental results.
    Janssen D; Mann KA; Verdonschot N
    J Orthop Res; 2009 Oct; 27(10):1312-8. PubMed ID: 19340877
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The influence of cement mantle thickness and stem geometry on fatigue damage in two different cemented hip femoral prostheses.
    Ramos A; Simões JA
    J Biomech; 2009 Nov; 42(15):2602-10. PubMed ID: 19660758
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cement oscillation increases interlock strength at the cement-bone interface, with commentary.
    Wang Y; Han P; Gu W; Shi Z; Li D; Wang C
    Orthopedics; 2009 May; 32(5):325; discussion 325. PubMed ID: 19472963
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fatigue creep damage at the cement-bone interface: an experimental and a micro-mechanical finite element study.
    Waanders D; Janssen D; Miller MA; Mann KA; Verdonschot N
    J Biomech; 2009 Nov; 42(15):2513-9. PubMed ID: 19682690
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of bone porosity on the shear strength of the bone-cement interface.
    Amirfeyz R; Bannister G
    Int Orthop; 2009 Jun; 33(3):843-6. PubMed ID: 18437380
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of three-dimensional shape optimization on the probabilistic response of a cemented femoral hip prosthesis.
    Nicolella DP; Thacker BH; Katoozian H; Davy DT
    J Biomech; 2006; 39(7):1265-78. PubMed ID: 15961093
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The use of complementary non-destructive evaluation methods to evaluate the integrity of the cement-bone interface.
    Leung SY; New AM; Browne M
    Proc Inst Mech Eng H; 2009 Jan; 223(1):75-86. PubMed ID: 19239069
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Predicting the failure response of cement-bone constructs using a non-linear fracture mechanics approach.
    Mann KA; Damron LA
    J Biomech Eng; 2002 Aug; 124(4):462-70. PubMed ID: 12188213
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of bone density on the cement fixation of femoral hip resurfacing components.
    Bitsch RG; Jäger S; Lürssen M; Loidolt T; Schmalzried TP; Clarius M
    J Orthop Res; 2010 Aug; 28(8):986-91. PubMed ID: 20162694
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Influence of proximal stem geometry and stem-cement interface characteristics on bone and cement stresses in femoral hip arthroplasty: finite element analysis].
    Massin P; Astoin E; Lavaste F
    Rev Chir Orthop Reparatrice Appar Mot; 2003 Apr; 89(2):134-43. PubMed ID: 12844057
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In vivo loss of cement-bone interlock reduces fixation strength in total knee arthroplasties.
    Goodheart JR; Miller MA; Mann KA
    J Orthop Res; 2014 Aug; 32(8):1052-60. PubMed ID: 24777486
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cement mantle stress under retroversion torque at heel-strike.
    Afsharpoya B; Barton DC; Fisher J; Purbach B; Wroblewski M; Stewart TD
    Med Eng Phys; 2009 Dec; 31(10):1323-30. PubMed ID: 19879794
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Bone-cement interface of the glenoid component: stress analysis for varying cement thickness.
    Terrier A; Büchler P; Farron A
    Clin Biomech (Bristol, Avon); 2005 Aug; 20(7):710-7. PubMed ID: 15961203
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The behavior of the micro-mechanical cement-bone interface affects the cement failure in total hip replacement.
    Waanders D; Janssen D; Mann KA; Verdonschot N
    J Biomech; 2011 Jan; 44(2):228-34. PubMed ID: 21036358
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mechanical properties of a cemented porous implant interface.
    Beckmann NA; Bitsch RG; Seeger JB; Klotz MC; Kretzer JP; Jaeger S
    Acta Orthop; 2014 Sep; 85(5):531-7. PubMed ID: 24798109
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mixed-mode failure strength of implant-cement interface specimens with varying surface roughness.
    Zelle J; Janssen D; Peeters S; Brouwer C; Verdonschot N
    J Biomech; 2011 Feb; 44(4):780-3. PubMed ID: 21074772
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.