135 related articles for article (PubMed ID: 27370159)
1. A new form of the calibration curve in radiochromic dosimetry. Properties and results.
Tamponi M; Bona R; Poggiu A; Marini P
Med Phys; 2016 Jul; 43(7):4435. PubMed ID: 27370159
[TBL] [Abstract][Full Text] [Related]
2. Radiochromic film calibration for low-energy seed brachytherapy dose measurement.
Morrison H; Menon G; Sloboda RS
Med Phys; 2014 Jul; 41(7):072101. PubMed ID: 24989396
[TBL] [Abstract][Full Text] [Related]
3. Correcting lateral response artifacts from flatbed scanners for radiochromic film dosimetry.
Lewis D; Chan MF
Med Phys; 2015 Jan; 42(1):416-29. PubMed ID: 25563282
[TBL] [Abstract][Full Text] [Related]
4. Variations in dose distribution and optical properties of Gafchromic(TM) EBT2 film according to scanning mode.
Park S; Kang SK; Cheong KH; Hwang T; Kim H; Han T; Lee MY; Kim K; Bae H; Su Kim H; Han Kim J; Jae Oh S; Suh JS
Med Phys; 2012 May; 39(5):2524-35. PubMed ID: 22559623
[TBL] [Abstract][Full Text] [Related]
5. A prototype, glassless densitometer traceable to primary optical standards for quantitative radiochromic film dosimetry.
Rosen BS; Soares CG; Hammer CG; Kunugi KA; DeWerd LA
Med Phys; 2015 Jul; 42(7):4055-68. PubMed ID: 26133606
[TBL] [Abstract][Full Text] [Related]
6. GafChromic EBT film dosimetry with flatbed CCD scanner: a novel background correction method and full dose uncertainty analysis.
Saur S; Frengen J
Med Phys; 2008 Jul; 35(7):3094-101. PubMed ID: 18697534
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of Gafchromic® EBT3 films characteristics in therapy photon, electron and proton beams.
Sorriaux J; Kacperek A; Rossomme S; Lee JA; Bertrand D; Vynckier S; Sterpin E
Phys Med; 2013 Nov; 29(6):599-606. PubMed ID: 23107430
[TBL] [Abstract][Full Text] [Related]
8. Multichannel film dosimetry with nonuniformity correction.
Micke A; Lewis DF; Yu X
Med Phys; 2011 May; 38(5):2523-34. PubMed ID: 21776787
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry.
Ferreira BC; Lopes MC; Capela M
Phys Med Biol; 2009 Feb; 54(4):1073-85. PubMed ID: 19168937
[TBL] [Abstract][Full Text] [Related]
10. Calibration of EBT2 film by the PDD method with scanner non-uniformity correction.
Chang L; Chui CS; Ding HJ; Hwang IM; Ho SY
Phys Med Biol; 2012 Sep; 57(18):5875-87. PubMed ID: 22951587
[TBL] [Abstract][Full Text] [Related]
11. Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams.
Brown TA; Hogstrom KR; Alvarez D; Matthews KL; Ham K; Dugas JP
Med Phys; 2012 Dec; 39(12):7412-7. PubMed ID: 23231291
[TBL] [Abstract][Full Text] [Related]
12. Radiochromic film dosimetry: considerations on precision and accuracy for EBT2 and EBT3 type films.
Dreindl R; Georg D; Stock M
Z Med Phys; 2014 May; 24(2):153-63. PubMed ID: 24055395
[TBL] [Abstract][Full Text] [Related]
13. The response of the new MD-V2-55 radiochromic film exposed to 60Co gamma rays.
Massillon-Jl G; Zúñiga-Meneses L
Phys Med Biol; 2010 Sep; 55(18):5437-49. PubMed ID: 20736498
[TBL] [Abstract][Full Text] [Related]
14. Technical Note: On GAFChromic EBT-XD film and the lateral response artifact.
Lewis DF; Chan MF
Med Phys; 2016 Feb; 43(2):643-9. PubMed ID: 26843228
[TBL] [Abstract][Full Text] [Related]
15. Linearization of dose-response curve of the radiochromic film dosimetry system.
Devic S; Tomic N; Aldelaijan S; Deblois F; Seuntjens J; Chan MF; Lewis D
Med Phys; 2012 Aug; 39(8):4850-7. PubMed ID: 22894411
[TBL] [Abstract][Full Text] [Related]
16. Calibration of GafChromic EBT3 for absorbed dose measurements in 5 MeV proton beam and (60)Co γ-rays.
Vadrucci M; Esposito G; Ronsivalle C; Cherubini R; Marracino F; Montereali RM; Picardi L; Piccinini M; Pimpinella M; Vincenti MA; De Angelis C
Med Phys; 2015 Aug; 42(8):4678-84. PubMed ID: 26233195
[TBL] [Abstract][Full Text] [Related]
17. Characterization of XR-RV3 GafChromic(®) films in standard laboratory and in clinical conditions and means to evaluate uncertainties and reduce errors.
Farah J; Trianni A; Ciraj-Bjelac O; Clairand I; De Angelis C; Delle Canne S; Hadid L; Huet C; Jarvinen H; Negri A; Novák L; Pinto M; Siiskonen T; Waryn MJ; Knežević Ž
Med Phys; 2015 Jul; 42(7):4211-26. PubMed ID: 26133620
[TBL] [Abstract][Full Text] [Related]
18. A new correction method serving to eliminate the parabola effect of flatbed scanners used in radiochromic film dosimetry.
Poppinga D; Schoenfeld AA; Doerner KJ; Blanck O; Harder D; Poppe B
Med Phys; 2014 Feb; 41(2):021707. PubMed ID: 24506598
[TBL] [Abstract][Full Text] [Related]
19. Gafchromic EBT2 film dosimetry in reflection mode with a novel plan-based calibration method.
Mendez I; Hartman V; Hudej R; Strojnik A; Casar B
Med Phys; 2013 Jan; 40(1):011720. PubMed ID: 23298090
[TBL] [Abstract][Full Text] [Related]
20. An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan.
Lewis D; Micke A; Yu X; Chan MF
Med Phys; 2012 Oct; 39(10):6339-50. PubMed ID: 23039670
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]