These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
199 related articles for article (PubMed ID: 27383659)
21. [Biological monitoring of occupational exposure to sevoflurane]. Imbriani M; Zadra P; Negri S; Alessio A; Maestri L; Ghittori S Med Lav; 2001; 92(3):173-80. PubMed ID: 11515150 [TBL] [Abstract][Full Text] [Related]
22. Nitrous oxide occupational exposure in conscious sedation procedures in dental ambulatories: a pilot retrospective observational study in an Italian pediatric hospital. Zaffina S; Lembo M; Gilardi F; Bussu A; Pattavina F; Tucci MG; Moscato U; Raponi M; Derrico P; Galeotti A; Camisa V BMC Anesthesiol; 2019 Mar; 19(1):42. PubMed ID: 30917782 [TBL] [Abstract][Full Text] [Related]
23. Evaluation of two nitrous oxide scavenging systems using infrared thermography to visualize and control emissions. Rademaker AM; McGlothlin JD; Moenning JE; Bagnoli M; Carlson G; Griffin C J Am Dent Assoc; 2009 Feb; 140(2):190-9; quiz 248-9. PubMed ID: 19188416 [TBL] [Abstract][Full Text] [Related]
24. A follow-up study on occupational exposure to inhaled anaesthetics in Eastern European surgeons and circulating nurses. Wiesner G; Harth M; Szulc R; Jurczyk W; Sobczynski P; Hoerauf KH; Hobbhahn J; Taeger K Int Arch Occup Environ Health; 2001 Jan; 74(1):16-20. PubMed ID: 11196076 [TBL] [Abstract][Full Text] [Related]
25. [Occupational exposure to nitrous oxide and sevoflurane during pediatric anesthesia: evaluation of an anesthetic gas extractor]. Sanabria Carretero P; Rodríguez Pérez E; Jiménez Mateos E; Palomero Rodríguez E; Goldman Tarlousky L; Gilsanz Rodriguez F; García Caballeroa J Rev Esp Anestesiol Reanim; 2006 Dec; 53(10):618-25. PubMed ID: 17302075 [TBL] [Abstract][Full Text] [Related]
26. Exposure control practices for administering nitrous oxide: A survey of dentists, dental hygienists, and dental assistants. Boiano JM; Steege AL; Sweeney MH J Occup Environ Hyg; 2017 Jun; 14(6):409-416. PubMed ID: 27937086 [TBL] [Abstract][Full Text] [Related]
27. Nitrous oxide scavenging in dental surgery. I. A comparison of the efficiency of different scavenging devices. Hallonsten AL Swed Dent J; 1982; 6(5):203-13. PubMed ID: 6217569 [TBL] [Abstract][Full Text] [Related]
28. Nitrous oxide exposure during routine anaesthetic work. Measurement of biologic exposure from urine samples and technical exposure by bag sampling. Sonander H; Stenqvist O; Nilsson K Acta Anaesthesiol Scand; 1985 Feb; 29(2):203-8. PubMed ID: 3976334 [TBL] [Abstract][Full Text] [Related]
29. [Pollution of the work environment by volatile anesthetics and nitrous oxide]. Marx T Anasthesiol Intensivmed Notfallmed Schmerzther; 1997 Sep; 32(9):532-40. PubMed ID: 9417253 [TBL] [Abstract][Full Text] [Related]
30. The effect of local scavenging on occupational exposure to nitrous oxide. Carlsson P; Ljungqvist B; Hallén B Acta Anaesthesiol Scand; 1983 Dec; 27(6):470-5. PubMed ID: 6666524 [TBL] [Abstract][Full Text] [Related]
31. Effectiveness of 2 scavenger mask systems for reducing exposure to nitrous oxide in a hospital-based pediatric dental clinic: a pilot study. Freilich MM; Alexander L; Sándor GK; Judd P J Can Dent Assoc; 2007 Sep; 73(7):615. PubMed ID: 17868510 [TBL] [Abstract][Full Text] [Related]
32. A placebo-controlled, double-blind, crossover trial on analgesic effect of nitrous oxide-oxygen inhalation. Grønbæk AB; Svensson P; Væth M; Hansen I; Poulsen S Int J Paediatr Dent; 2014 Jan; 24(1):69-75. PubMed ID: 23464746 [TBL] [Abstract][Full Text] [Related]
33. Neurobehavioral functions in operating theatre personnel: a multicenter study. Lucchini R; Belotti L; Cassitto MG; Faillace A; Margonari M; Micheloni G; Scapellato ML; Somenzi V; Spada T; Toffoletto F; Gilioli R Med Lav; 1997; 88(5):396-405. PubMed ID: 9489303 [TBL] [Abstract][Full Text] [Related]
35. [Occupational exposure to inhalation anesthetics at the work-place of veterinary surgery]. Hoerauf K; Lierz M; Schrögendorfer K; Felleiter P; Madei W; Lierz P; Brunnberg L Zentralbl Hyg Umweltmed; 1998 Dec; 201(4-5):405-12. PubMed ID: 9916294 [TBL] [Abstract][Full Text] [Related]
36. Evaluation of personal, environmental and biological exposure of paediatric anaesthetists to nitrous oxide and sevoflurane. Raj N; Henderson KA; Hall JE; Aguilera IM; Harmer M; Hutchings A; Williams B Anaesthesia; 2003 Jul; 58(7):630-6. PubMed ID: 12790811 [TBL] [Abstract][Full Text] [Related]
38. Environmental monitoring of sevoflurane and nitrous oxide using the cuffed oropharyngeal airway. Gustorff B; Lorenzl N; Aram L; Krenn CG; Jobst BP; Hoerauf KH Anesth Analg; 2002 May; 94(5):1244-8, table of contents. PubMed ID: 11973198 [TBL] [Abstract][Full Text] [Related]
39. [Measurements and environmental and biological monitoring of occupational exposure to inhalation anesthetics]. Imbriani M; Andreoletti F; Baj A; Bolzoni G; Buratti M; Cantoni S; Cecchetti R; Colombi A; Ghittori S; Imberti R G Ital Med Lav; 1992; 14(1-6):11-24. PubMed ID: 1345714 [TBL] [Abstract][Full Text] [Related]
40. [Pollution level during inhalation sedation with a 50%N2O/50%O2 premix: comparison of two administration devices]. Hennequin M; Onody P Ann Fr Anesth Reanim; 2004 Oct; 23(10):959-65. PubMed ID: 15501625 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]