969 related articles for article (PubMed ID: 2739424)
21. Aspire porcine bioprosthesis: ten years' experience.
Hadjinikolaou L; Boehm MC; Ganner C; Kendall SW; Rosin MD; Goldsmith IR; Spyt TJ
J Heart Valve Dis; 2005 Jan; 14(1):47-53. PubMed ID: 15700436
[TBL] [Abstract][Full Text] [Related]
22. Clinical results of pericardial xenograft valves: the Ionescu-Shiley and Hancock valves.
Goldman B; Scully H; Tong C; Mandell R; Butany J; Azuma J; Schwartz L
Can J Cardiol; 1988 Sep; 4(6):328-32. PubMed ID: 3179796
[TBL] [Abstract][Full Text] [Related]
23. Late results of heart valve replacement with the Hancock II bioprosthesis.
David TE; Ivanov J; Armstrong S; Feindel CM; Cohen G
J Thorac Cardiovasc Surg; 2001 Feb; 121(2):268-77. PubMed ID: 11174732
[TBL] [Abstract][Full Text] [Related]
24. The Carpentier-Edwards standard porcine bioprosthesis. A first-generation tissue valve with excellent long-term clinical performance.
Jamieson WR; Allen P; Miyagishima RT; Gerein AN; Munro AI; Burr LH; Tyers GF
J Thorac Cardiovasc Surg; 1990 Mar; 99(3):543-61. PubMed ID: 2308373
[TBL] [Abstract][Full Text] [Related]
25. Simultaneous aortic and mitral valve replacement: predictors of adverse outcome.
Kuwaki K; Tsukamoto M; Komatsu K; Morishita K; Sakata J; Abe T
J Heart Valve Dis; 2003 Mar; 12(2):169-76. PubMed ID: 12701788
[TBL] [Abstract][Full Text] [Related]
26. Mitral valve replacement with the Hancock, Björk-Shiley and Lillehei-Kaster prostheses. A comparison based on a 15-year follow-up.
Milano A; Bortolotti U; Mazzucco A; Guerra F; Magni A; Stellin G; Gallucci V
Eur J Cardiothorac Surg; 1989; 3(4):312-9; discussion 319-20. PubMed ID: 2624803
[TBL] [Abstract][Full Text] [Related]
27. Comparison of porcine valve xenografts with mechanical prostheses. A 7 1/2 year experience.
Joyce LD; Nelson RM
J Thorac Cardiovasc Surg; 1984 Jul; 88(1):102-13. PubMed ID: 6738092
[TBL] [Abstract][Full Text] [Related]
28. Simultaneous implantation of St. Jude Medical aortic and mitral prostheses.
Armenti F; Stephenson LW; Edmunds LH
J Thorac Cardiovasc Surg; 1987 Nov; 94(5):733-9. PubMed ID: 3669701
[TBL] [Abstract][Full Text] [Related]
29. A prospective evaluation of the Björk-Shiley, Hancock, and Carpentier-Edwards heart valve prostheses.
Bloomfield P; Kitchin AH; Wheatley DJ; Walbaum PR; Lutz W; Miller HC
Circulation; 1986 Jun; 73(6):1213-22. PubMed ID: 3516447
[TBL] [Abstract][Full Text] [Related]
30. Three-year clinical results with the Monostrut Björk-Shiley prosthesis.
Lindblom D; Lindblom U; Henze A; Björk VO; Semb BK
J Thorac Cardiovasc Surg; 1987 Jul; 94(1):34-43. PubMed ID: 3600006
[TBL] [Abstract][Full Text] [Related]
31. Seventeen-year experience with the St. Jude medical biocor porcine bioprosthesis.
Mykén PS
J Heart Valve Dis; 2005 Jul; 14(4):486-92. PubMed ID: 16116875
[TBL] [Abstract][Full Text] [Related]
32. Valve replacement in children under twenty years of age. Experience with the Björk-Shiley prosthesis.
Iyer KS; Reddy KS; Rao IM; Venugopal P; Bhatia ML; Gopinath N
J Thorac Cardiovasc Surg; 1984 Aug; 88(2):217-24. PubMed ID: 6748715
[TBL] [Abstract][Full Text] [Related]
33. [Long-term follow-up of aortic or mitral valve replacement. Comparison of results following implantation of a mechanical or biological artificial valve].
Mudra H; Rudolph W
Herz; 1986 Apr; 11(2):97-115. PubMed ID: 3699678
[TBL] [Abstract][Full Text] [Related]
34. Twelve-year experience with the 19 mm Carpentier-Edwards pericardial aortic valve.
Nakajima H; Aupart MR; Neville PH; Sirinelli AL; Meurisse YA; Marchand MA
J Heart Valve Dis; 1998 Sep; 7(5):534-9. PubMed ID: 9793853
[TBL] [Abstract][Full Text] [Related]
35. Four years' experience with the Edwards-Tekna bileaflet valve prosthesis.
Calkavur T; Yagdi T; Apaydin A; Islamoglu F; Posacioglu H; Durmaz I; Ozbaran M
J Heart Valve Dis; 2002 Mar; 11(2):263-9. PubMed ID: 12000170
[TBL] [Abstract][Full Text] [Related]
36. Clinical evaluation of the carbomedics prosthesis: experience at providence health system in Portland.
Minakata K; Wu Y; Zerr KJ; Grunkemeier GL; Handy JR; Ahmad A; Starr A; Furnary AP
J Heart Valve Dis; 2002 Nov; 11(6):844-50. PubMed ID: 12479287
[TBL] [Abstract][Full Text] [Related]
37. Clinical evaluation of the Omniscience cardiac valve prosthesis. Follow-up of up to 6 years.
Akalin H; Corapçioğlu ET; Ozyurda U; Uçanok K; Uysalel A; Kaya B; Eren NT; Erol C
J Thorac Cardiovasc Surg; 1992 Feb; 103(2):259-66. PubMed ID: 1735991
[TBL] [Abstract][Full Text] [Related]
38. An eight-year experience with porcine bioprosthetic cardiac valves.
Hartz RS; Fisher EB; Finkelmeier B; DeBoer A; Sanders JH; Moran JM; Michaelis LL
J Thorac Cardiovasc Surg; 1986 Jun; 91(6):910-7. PubMed ID: 3713240
[TBL] [Abstract][Full Text] [Related]
39. [Long-term results over 20 years of aortic valve replacement with the standard Björk-Shiley prosthesis].
Valla J; Langanay T; Corbineau H; Sevray B; Chaperon J; Menestret P; Lelong B; Leguerrier A; Rioux C; Logeais Y
Arch Mal Coeur Vaiss; 1996 Sep; 89(9):1137-43. PubMed ID: 8952837
[TBL] [Abstract][Full Text] [Related]
40. More than ten years' follow-up of the Hancock porcine bioprosthesis in Japan.
Kawachi Y; Tanaka J; Tominaga R; Kinoshita K; Tokunaga K
J Thorac Cardiovasc Surg; 1992 Jul; 104(1):5-13. PubMed ID: 1614215
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]