BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

279 related articles for article (PubMed ID: 27395028)

  • 1. Performance enhancement of zero valent iron based systems using depassivators: Optimization and kinetic mechanisms.
    Ansaf KVK; Ambika S; Nambi IM
    Water Res; 2016 Oct; 102():436-444. PubMed ID: 27395028
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reductive removal of selenate by zero-valent iron: The roles of aqueous Fe(2+) and corrosion products, and selenate removal mechanisms.
    Tang C; Huang YH; Zeng H; Zhang Z
    Water Res; 2014 Dec; 67():166-74. PubMed ID: 25269108
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The limitations of applying zero-valent iron technology in contaminants sequestration and the corresponding countermeasures: the development in zero-valent iron technology in the last two decades (1994-2014).
    Guan X; Sun Y; Qin H; Li J; Lo IM; He D; Dong H
    Water Res; 2015 May; 75():224-48. PubMed ID: 25770444
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Performance and mechanism of Cr(VI) removal by zero-valent iron loaded onto expanded graphite.
    Xu C; Yang W; Liu W; Sun H; Jiao C; Lin AJ
    J Environ Sci (China); 2018 May; 67():14-22. PubMed ID: 29778146
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Weak magnetic field accelerates chromate removal by zero-valent iron.
    Feng P; Guan X; Sun Y; Choi W; Qin H; Wang J; Qiao J; Li L
    J Environ Sci (China); 2015 May; 31():175-83. PubMed ID: 25968271
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Electrochemical depassivation of zero-valent iron for trichloroethene reduction.
    Chen L; Jin S; Fallgren PH; Swoboda-Colberg NG; Liu F; Colberg PJ
    J Hazard Mater; 2012 Nov; 239-240():265-9. PubMed ID: 23009798
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assessment of zero-valent iron as a permeable reactive barrier for long-term removal of arsenic compounds from synthetic water.
    Lee KJ; Lee Y; Yoon J; Kamala-Kannan S; Park SM; Oh BT
    Environ Technol; 2009 Dec; 30(13):1425-34. PubMed ID: 20088207
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Zero-valent iron for the abatement of arsenate and selenate from flowback water of hydraulic fracturing.
    Sun Y; Chen SS; Tsang DCW; Graham NJD; Ok YS; Feng Y; Li XD
    Chemosphere; 2017 Jan; 167():163-170. PubMed ID: 27718428
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Kinetics and mechanisms of pH-dependent selenite removal by zero valent iron.
    Liang L; Yang W; Guan X; Li J; Xu Z; Wu J; Huang Y; Zhang X
    Water Res; 2013 Oct; 47(15):5846-55. PubMed ID: 23899877
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Minor chromium passivation of S-ZVI enhanced the long-term dechlorination performance of trichlorethylene: Effects of corrosion and passivation on the reactivity and selectivity.
    Guo J; Wang D; Shi Y; Lyu H; Tang J
    Water Res; 2024 Feb; 249():120973. PubMed ID: 38071903
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Zero-valent iron treatment of dark brown colored coffee effluent: Contributions of a core-shell structure to pollutant removals.
    Tomizawa M; Kurosu S; Kobayashi M; Kawase Y
    J Environ Manage; 2016 Dec; 183(Pt 3):478-487. PubMed ID: 27623374
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Enhanced removal of Se(VI) from water via pre-corrosion of zero-valent iron using H
    Shan C; Chen J; Yang Z; Jia H; Guan X; Zhang W; Pan B
    Water Res; 2018 Apr; 133():173-181. PubMed ID: 29407699
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Removal of nitrate from water by acid-washed zero-valent iron/ferrous ion/hydrogen peroxide: influencing factors and reaction mechanism.
    Li Y; Fu F; Ding Z
    Water Sci Technol; 2018 Jan; 77(1-2):525-533. PubMed ID: 29377837
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The specific reactive surface area of granular zero-valent iron in metal contaminant removal: Column experiments and modelling.
    Statham TM; Mason LR; Mumford KA; Stevens GW
    Water Res; 2015 Jun; 77():24-34. PubMed ID: 25839833
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Coupled effects of aging and weak magnetic fields on sequestration of selenite by zero-valent iron.
    Liang L; Guan X; Shi Z; Li J; Wu Y; Tratnyek PG
    Environ Sci Technol; 2014 Jun; 48(11):6326-34. PubMed ID: 24804570
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Promoted iron corrosion and subsequent hexavalent chromium removal in zero-valent iron systems by oxidant activation.
    Chen W; Li B; Yin W; Zeng W; Li P; Wu J
    Chemosphere; 2024 Mar; 352():141391. PubMed ID: 38325615
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Degradation of organic compounds during the corrosion of ZVI by hydrogen peroxide at neutral pH: Kinetics, mechanisms and effect of corrosion promoting and inhibiting ions.
    Ling R; Chen JP; Shao J; Reinhard M
    Water Res; 2018 May; 134():44-53. PubMed ID: 29407650
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Amicarbazone degradation promoted by ZVI-activated persulfate: study of relevant variables for practical application.
    Graça CAL; Fugita LTN; de Velosa AC; Teixeira ACSC
    Environ Sci Pollut Res Int; 2018 Feb; 25(6):5474-5483. PubMed ID: 29214480
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Weak magnetic field significantly enhances selenite removal kinetics by zero valent iron.
    Liang L; Sun W; Guan X; Huang Y; Choi W; Bao H; Li L; Jiang Z
    Water Res; 2014 Feb; 49():371-80. PubMed ID: 24199999
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Selenate removal by zero-valent iron in oxic condition: the role of Fe(II) and selenate removal mechanism.
    Yoon IH; Bang S; Kim KW; Kim MG; Park SY; Choi WK
    Environ Sci Pollut Res Int; 2016 Jan; 23(2):1081-90. PubMed ID: 25943509
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.