These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 27400638)

  • 1. Saphenous vein bypass graft intervention and embolic protection devices: Time for reassessment (and revision of percutaneous coronary intervention guidelines).
    Safian RD
    Catheter Cardiovasc Interv; 2016 Jul; 88(1):84-5. PubMed ID: 27400638
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Contemporary use of embolic protection devices in saphenous vein graft interventions: Insights from the stenting of saphenous vein grafts trial.
    Badhey N; Lichtenwalter C; de Lemos JA; Roesle M; Obel O; Addo TA; Haagen D; Abdel-Karim AR; Saeed B; Bissett JK; Sachdeva R; Voudris VV; Karyofillis P; Kar B; Rossen J; Fasseas P; Berger PB; Banerjee S; Brilakis ES
    Catheter Cardiovasc Interv; 2010 Aug; 76(2):263-9. PubMed ID: 20665875
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Outcomes Following Percutaneous Coronary Intervention in Saphenous Vein Grafts With and Without Embolic Protection Devices.
    Shoaib A; Kinnaird T; Curzen N; Ludman P; Smith D; Khoo CW; Kontopantelis E; Rashid M; Mohamed M; Nolan J; Zaman A; Mamas MA; ;
    JACC Cardiovasc Interv; 2019 Nov; 12(22):2286-2295. PubMed ID: 31753300
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Contemporary use of embolic protection devices in saphenous vein graft interventions: insights from the stent of saphenous vein grafts trial.
    Heuser RR
    Catheter Cardiovasc Interv; 2011 Mar; 77(4):594. PubMed ID: 21351235
    [No Abstract]   [Full Text] [Related]  

  • 5. Percutaneous saphenous vein graft intervention with sequential embolic protection devices: complementing lesion anatomy with embolic protection device.
    Grow P; Rab ST
    Catheter Cardiovasc Interv; 2008 Nov; 72(5):636-40. PubMed ID: 18942125
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Embolic protection device use and its association with procedural safety and long-term outcomes following saphenous vein graft intervention: An analysis from the British Columbia Cardiac registry.
    Iqbal MB; Nadra IJ; Ding L; Fung A; Aymong E; Chan AW; Hodge S; Della Siega A; Robinson SD;
    Catheter Cardiovasc Interv; 2016 Jul; 88(1):73-83. PubMed ID: 26482020
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Embolic protection device use and outcomes in patients receiving saphenous vein graft interventions--a single-center experience.
    Golwala H; Hawkins BM; Stavrakis S; Abu-Fadel MS
    J Invasive Cardiol; 2012 Jan; 24(1):1-3. PubMed ID: 22210580
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Contemporary Use of Embolic Protection Devices During Saphenous Vein Graft Intervention.
    Valle JA; Glorioso TJ; Schuetze KB; Grunwald GK; Armstrong EJ; Waldo SW
    Circ Cardiovasc Interv; 2019 May; 12(5):e007636. PubMed ID: 31014092
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rebuttal: innovative embolic protection strategies for saphenous vein graft interventions.
    Badhey N; Banerjee S; Brilakis ES
    Catheter Cardiovasc Interv; 2011 Mar; 77(4):595. PubMed ID: 21351236
    [No Abstract]   [Full Text] [Related]  

  • 10. Correlates of adverse events during saphenous vein graft intervention with distal embolic protection: a PRIDE substudy.
    Kirtane AJ; Heyman ER; Metzger C; Breall JA; Carrozza JP
    JACC Cardiovasc Interv; 2008 Apr; 1(2):186-91. PubMed ID: 19463299
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Outcomes of Saphenous Vein Graft Intervention With and Without Embolic Protection Device: A Comprehensive Review and Meta-Analysis.
    Paul TK; Bhatheja S; Panchal HB; Zheng S; Banerjee S; Rao SV; Guzman L; Beohar N; Zhao D; Mehran R; Mukherjee D
    Circ Cardiovasc Interv; 2017 Dec; 10(12):. PubMed ID: 29246912
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A novel filter-based distal embolic protection device for percutaneous intervention of saphenous vein graft lesions: results of the AMEthyst randomized controlled trial.
    Kereiakes DJ; Turco MA; Breall J; Farhat NZ; Feldman RL; McLaurin B; Popma JJ; Mauri L; Zimetbaum P; Massaro J; Cutlip DE;
    JACC Cardiovasc Interv; 2008 Jun; 1(3):248-57. PubMed ID: 19463308
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Selective use of embolic protection devices during saphenous vein grafts interventions: a single-center experience.
    Lavi S; Ivanov J; Appleby CE; Seidelin PH; Mackie K; Schwartz L; Dzavík V
    Catheter Cardiovasc Interv; 2010 Jun; 75(7):1037-44. PubMed ID: 20517966
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Contemporary approaches to saphenous vein graft interventions: a survey of 275 interventional cardiologists.
    Mahmood A; Khair T; Abdel-karim AR; Papayannis A; Xu H; Banerjee S; Brilakis ES
    Catheter Cardiovasc Interv; 2012 Apr; 79(5):834-42. PubMed ID: 21538790
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Percutaneous intervention of a thrombotic-occluded saphenous vein graft successfully treated using the undersized stent approach to prevent distal embolization.
    Maluenda G; Alfonso F; Pichard AD
    Catheter Cardiovasc Interv; 2011 Jul; 78(1):65-9. PubMed ID: 21328690
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Utilization of distal embolic protection in saphenous vein graft interventions (an analysis of 19,546 patients in the American College of Cardiology-National Cardiovascular Data Registry).
    Mehta SK; Frutkin AD; Milford-Beland S; Klein LW; Shaw RE; Weintraub WS; Krone RJ; Anderson HV; Kutcher MA; Marso SP;
    Am J Cardiol; 2007 Oct; 100(7):1114-8. PubMed ID: 17884373
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Use of the Proxis embolic protection device for guide anchoring and stent delivery during complex saphenous vein graft interventions.
    Banerjee S; Brilakis ES
    Cardiovasc Revasc Med; 2009; 10(3):183-7. PubMed ID: 19595401
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In-hospital outcomes and usage of embolic protection devices in percutaneous coronary intervention for coronary artery bypass grafts: Insights from a Japanese nationwide registry.
    Oba Y; Inohara T; Takahashi M; Fukutomi M; Funayama H; Ando H; Kohsaka S; Amano T; Ikari Y; Kario K
    Catheter Cardiovasc Interv; 2021 Sep; 98(3):E356-E364. PubMed ID: 33861509
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Low frequency of embolic protection devices in saphenous vein intervention: a matter of lack of conviction?
    Lozano I; Rondan J; Avanzas P; Suarez CP
    Catheter Cardiovasc Interv; 2014 Jul; 84(1):E4. PubMed ID: 20853360
    [No Abstract]   [Full Text] [Related]  

  • 20. Rebuttal: Use of embolic protection devices in saphenous vein graft interventions: the ongoing challenge.
    Badhey N; Banerjee S; Brilakis ES
    Catheter Cardiovasc Interv; 2014 Jul; 84(1):E5-6. PubMed ID: 20853356
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.