These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 27402558)

  • 1. Correcting the dynamic response of a commercial esophageal balloon-catheter.
    Cross TJ; Beck KC; Johnson BD
    J Appl Physiol (1985); 2016 Aug; 121(2):503-11. PubMed ID: 27402558
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Frequency responses of infant air-balloon versus liquid-filled catheters for intra-esophageal pressure measurement.
    Hartford CG; Turner MJ; van Schalkwyk JM; Rogers GG
    Pediatr Pulmonol; 1997 Nov; 24(5):353-63. PubMed ID: 9407569
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Stability and Agreement of a Microtransducer and an Air-Filled Balloon Esophageal Catheter in the Monitoring of Esophageal Pressure.
    Augusto RM; Albuquerque AL; Jaeger T; de Carvalho CR; Caruso P
    Respir Care; 2017 Feb; 62(2):215-221. PubMed ID: 27729399
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessing respiratory function depends on mechanical characteristics of balloon catheters.
    Walterspacher S; Isaak L; Guttmann J; Kabitz HJ; Schumann S
    Respir Care; 2014 Sep; 59(9):1345-52. PubMed ID: 24381189
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Response characteristics of esophageal balloon catheters handmade using latex and nonlatex materials.
    Cross TJ; Lalande S; Hyatt RE; Johnson BD
    Physiol Rep; 2015 Jun; 3(6):. PubMed ID: 26077619
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurements Obtained From Esophageal Balloon Catheters Are Affected by the Esophageal Balloon Filling Volume in Children With ARDS.
    Hotz JC; Sodetani CT; Van Steenbergen J; Khemani RG; Deakers TW; Newth CJ
    Respir Care; 2018 Feb; 63(2):177-186. PubMed ID: 29089460
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of the catheter diameter on the investigation of the esophageal motility through solid-state high-resolution manometry.
    Xiang X; Tu L; Zhang X; Xie X; Hou X
    Dis Esophagus; 2013; 26(7):661-7. PubMed ID: 23384164
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of Cardiac Cycle Locating to Minimize the Influence of Cardiac Artifacts on Esophageal Pressure Measurement During Dynamic Occlusion Test.
    He X; Sun XM; Chen GQ; Yang YL; Shi ZH; Xu M; Zhou JX
    Respir Care; 2018 Feb; 63(2):169-176. PubMed ID: 29066585
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pressure measurement characteristics of a micro-transducer and balloon catheters.
    MacAskill W; Hoffman B; Johnson MA; Sharpe GR; Mills DE
    Physiol Rep; 2021 Apr; 9(8):e14831. PubMed ID: 33938126
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Esophageal balloon catheter system identification to improve respiratory effort time features and amplitude determination.
    Xia YHW; Victor MH; Morais CCA; Costa ELV; Amato MBP
    Physiol Meas; 2024 Jan; 45(1):. PubMed ID: 38086063
    [No Abstract]   [Full Text] [Related]  

  • 11. Studies of the dynamic response of esophageal manometry systems.
    Pettersson GB; Kronogård CO; Rådmark T
    Scand J Gastroenterol; 1986 Apr; 21(3):305-12. PubMed ID: 3715396
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Frequency content of esophageal peristaltic pressure.
    Ask P; Oberq PA; Tibbling L
    Am J Physiol; 1979 Mar; 236(3):E296-300. PubMed ID: 426061
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Correctly selecting a liquid-filled nasogastric infant feeding catheter to measure intraesophageal pressure.
    Hartford CG; Rogers GG; Turner MJ
    Pediatr Pulmonol; 1997 May; 23(5):362-9. PubMed ID: 9168510
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Esophageal pressure measurements under different conditions of intrathoracic pressure. An in vitro study of second generation balloon catheters.
    Mojoli F; Chiumello D; Pozzi M; Algieri I; Bianzina S; Luoni S; Volta CA; Braschi A; Brochard L
    Minerva Anestesiol; 2015 Aug; 81(8):855-64. PubMed ID: 25634481
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Deglutitive upper esophageal sphincter relaxation: a study of 75 volunteer subjects using solid-state high-resolution manometry.
    Ghosh SK; Pandolfino JE; Zhang Q; Jarosz A; Kahrilas PJ
    Am J Physiol Gastrointest Liver Physiol; 2006 Sep; 291(3):G525-31. PubMed ID: 16645162
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Normal values for esophageal high-resolution manometry.
    Bogte A; Bredenoord AJ; Oors J; Siersema PD; Smout AJ
    Neurogastroenterol Motil; 2013 Sep; 25(9):762-e579. PubMed ID: 23803156
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new microtransducer catheter for measuring esophageal pressure in infants.
    Gappa M; Jackson E; Pilgrim L; Costeloe K; Stocks J
    Pediatr Pulmonol; 1996 Aug; 22(2):117-24. PubMed ID: 8875586
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Esophageal and transpulmonary pressures in acute respiratory failure.
    Talmor D; Sarge T; O'Donnell CR; Ritz R; Malhotra A; Lisbon A; Loring SH
    Crit Care Med; 2006 May; 34(5):1389-94. PubMed ID: 16540960
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Balloon sensors for the manometric recording of the pharyngoesophageal tract: an experimental study.
    Mattioli S; Lugaresi M; Zannoli R; Brusori S; d'Ovidio F
    Dysphagia; 2003; 18(4):249-54. PubMed ID: 14571328
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Disposable balloon-based oesophageal motility catheters: comparison with solid-state transducers.
    Tutuian R; Agrawal A; Mainie I; Freeman J; Castell DO
    Neurogastroenterol Motil; 2005 Jun; 17(3):453-7. PubMed ID: 15916633
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.