These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 27410816)

  • 1. Four-channel optically pumped atomic magnetometer for magnetoencephalography.
    Colombo AP; Carter TR; Borna A; Jau YY; Johnson CN; Dagel AL; Schwindt PD
    Opt Express; 2016 Jul; 24(14):15403-16. PubMed ID: 27410816
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reducing crosstalk in optically-pumped magnetometer arrays.
    Nardelli NV; Krzyzewski SP; Knappe SA
    Phys Med Biol; 2019 Nov; 64(21):21NT03. PubMed ID: 31593936
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Theoretical advantages of a triaxial optically pumped magnetometer magnetoencephalography system.
    Brookes MJ; Boto E; Rea M; Shah V; Osborne J; Holmes N; Hill RM; Leggett J; Rhodes N; Bowtell R
    Neuroimage; 2021 Aug; 236():118025. PubMed ID: 33838266
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Precision magnetic field modelling and control for wearable magnetoencephalography.
    Rea M; Holmes N; Hill RM; Boto E; Leggett J; Edwards LJ; Woolger D; Dawson E; Shah V; Osborne J; Bowtell R; Brookes MJ
    Neuroimage; 2021 Nov; 241():118401. PubMed ID: 34273527
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A high-performance compact magnetic shield for optically pumped magnetometer-based magnetoencephalography.
    He K; Wan S; Sheng J; Liu D; Wang C; Li D; Qin L; Luo S; Qin J; Gao JH
    Rev Sci Instrum; 2019 Jun; 90(6):064102. PubMed ID: 31254989
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Multi-channel whole-head OPM-MEG: Helmet design and a comparison with a conventional system.
    Hill RM; Boto E; Rea M; Holmes N; Leggett J; Coles LA; Papastavrou M; Everton SK; Hunt BAE; Sims D; Osborne J; Shah V; Bowtell R; Brookes MJ
    Neuroimage; 2020 Oct; 219():116995. PubMed ID: 32480036
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A study of scalar optically-pumped magnetometers for use in magnetoencephalography without shielding.
    Clancy RJ; Gerginov V; Alem O; Becker S; Knappe S
    Phys Med Biol; 2021 Sep; 66(17):. PubMed ID: 34325403
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A 20-channel magnetoencephalography system based on optically pumped magnetometers.
    Borna A; Carter TR; Goldberg JD; Colombo AP; Jau YY; Berry C; McKay J; Stephen J; Weisend M; Schwindt PDD
    Phys Med Biol; 2017 Nov; 62(23):8909-8923. PubMed ID: 29035875
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multi-channel atomic magnetometer for magnetoencephalography: a configuration study.
    Kim K; Begus S; Xia H; Lee SK; Jazbinsek V; Trontelj Z; Romalis MV
    Neuroimage; 2014 Apr; 89():143-51. PubMed ID: 24185014
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Non-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System.
    Borna A; Carter TR; Colombo AP; Jau YY; McKay J; Weisend M; Taulu S; Stephen JM; Schwindt PDD
    PLoS One; 2020; 15(1):e0227684. PubMed ID: 31978102
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measuring MEG closer to the brain: Performance of on-scalp sensor arrays.
    Iivanainen J; Stenroos M; Parkkonen L
    Neuroimage; 2017 Feb; 147():542-553. PubMed ID: 28007515
    [TBL] [Abstract][Full Text] [Related]  

  • 12. On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers.
    Iivanainen J; Zetter R; Grön M; Hakkarainen K; Parkkonen L
    Neuroimage; 2019 Jul; 194():244-258. PubMed ID: 30885786
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A subfemtotesla multichannel atomic magnetometer.
    Kominis IK; Kornack TW; Allred JC; Romalis MV
    Nature; 2003 Apr; 422(6932):596-9. PubMed ID: 12686995
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evolution of MEG: A first MEG-feasible fluxgate magnetometer.
    Koshev N; Butorina A; Skidchenko E; Kuzmichev A; Ossadtchi A; Ostras M; Fedorov M; Vetoshko P
    Hum Brain Mapp; 2021 Oct; 42(15):4844-4856. PubMed ID: 34327772
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A new generation of magnetoencephalography: Room temperature measurements using optically-pumped magnetometers.
    Boto E; Meyer SS; Shah V; Alem O; Knappe S; Kruger P; Fromhold TM; Lim M; Glover PM; Morris PG; Bowtell R; Barnes GR; Brookes MJ
    Neuroimage; 2017 Apr; 149():404-414. PubMed ID: 28131890
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multi-channel spin exchange relaxation free magnetometer towards two-dimensional vector magnetoencephalography.
    Zhang G; Huang S; Xu F; Hu Z; Lin Q
    Opt Express; 2019 Jan; 27(2):597-607. PubMed ID: 30696144
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Detection of human auditory evoked brain signals with a resilient nonlinear optically pumped magnetometer.
    Kowalczyk AU; Bezsudnova Y; Jensen O; Barontini G
    Neuroimage; 2021 Feb; 226():117497. PubMed ID: 33132074
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A compact, high performance atomic magnetometer for biomedical applications.
    Shah VK; Wakai RT
    Phys Med Biol; 2013 Nov; 58(22):8153-61. PubMed ID: 24200837
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measuring functional connectivity with wearable MEG.
    Boto E; Hill RM; Rea M; Holmes N; Seedat ZA; Leggett J; Shah V; Osborne J; Bowtell R; Brookes MJ
    Neuroimage; 2021 Apr; 230():117815. PubMed ID: 33524584
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cross-Axis projection error in optically pumped magnetometers and its implication for magnetoencephalography systems.
    Borna A; Iivanainen J; Carter TR; McKay J; Taulu S; Stephen J; Schwindt PDD
    Neuroimage; 2022 Feb; 247():118818. PubMed ID: 34915157
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.