These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

811 related articles for article (PubMed ID: 27412659)

  • 1. Extent of Myocardium at Risk for Left Anterior Descending Artery, Right Coronary Artery, and Left Circumflex Artery Occlusion Depicted by Contrast-Enhanced Steady State Free Precession and T2-Weighted Short Tau Inversion Recovery Magnetic Resonance Imaging.
    Nordlund D; Heiberg E; Carlsson M; Fründ ET; Hoffmann P; Koul S; Atar D; Aletras AH; Erlinge D; Engblom H; Arheden H
    Circ Cardiovasc Imaging; 2016 Jul; 9(7):. PubMed ID: 27412659
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multi-vendor, multicentre comparison of contrast-enhanced SSFP and T2-STIR CMR for determining myocardium at risk in ST-elevation myocardial infarction.
    Nordlund D; Klug G; Heiberg E; Koul S; Larsen TH; Hoffmann P; Metzler B; Erlinge D; Atar D; Aletras AH; Carlsson M; Engblom H; Arheden H
    Eur Heart J Cardiovasc Imaging; 2016 Jul; 17(7):744-53. PubMed ID: 27002140
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quantification of myocardium at risk in ST- elevation myocardial infarction: a comparison of contrast-enhanced steady-state free precession cine cardiovascular magnetic resonance with coronary angiographic jeopardy scores.
    De Palma R; Sörensson P; Verouhis D; Pernow J; Saleh N
    J Cardiovasc Magn Reson; 2017 Jul; 19(1):55. PubMed ID: 28750637
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Retrospective assessment of at-risk myocardium in reperfused acute myocardial infarction patients using contrast-enhanced balanced steady-state free-precession cardiovascular magnetic resonance at 3T with SPECT validation.
    Sun Z; Zhang Q; Zhao H; Yan C; Yang HJ; Li D; Li K; Liu Z; Yang Q; Dharmakumar R
    J Cardiovasc Magn Reson; 2021 Mar; 23(1):25. PubMed ID: 33715636
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Diagnostic Accuracy of 3.0-T Magnetic Resonance T1 and T2 Mapping and T2-Weighted Dark-Blood Imaging for the Infarct-Related Coronary Artery in Non-ST-Segment Elevation Myocardial Infarction.
    Layland J; Rauhalammi S; Lee MM; Ahmed N; Carberry J; Teng Yue May V; Watkins S; McComb C; Mangion K; McClure JD; Carrick D; O'Donnell A; Sood A; McEntegart M; Oldroyd KG; Radjenovic A; Berry C
    J Am Heart Assoc; 2017 Mar; 6(4):. PubMed ID: 28364045
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of myocardium at risk with contrast enhanced steady-state free precession cine cardiovascular magnetic resonance compared to single-photon emission computed tomography.
    Sörensson P; Heiberg E; Saleh N; Bouvier F; Caidahl K; Tornvall P; Rydén L; Pernow J; Arheden H
    J Cardiovasc Magn Reson; 2010 Apr; 12(1):25. PubMed ID: 20433716
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Experimental validation of contrast-enhanced SSFP cine CMR for quantification of myocardium at risk in acute myocardial infarction.
    Nordlund D; Kanski M; Jablonowski R; Koul S; Erlinge D; Carlsson M; Engblom H; Aletras AH; Arheden H
    J Cardiovasc Magn Reson; 2017 Jan; 19(1):12. PubMed ID: 28132648
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Myocardium at risk after acute infarction in humans on cardiac magnetic resonance: quantitative assessment during follow-up and validation with single-photon emission computed tomography.
    Carlsson M; Ubachs JF; Hedström E; Heiberg E; Jovinge S; Arheden H
    JACC Cardiovasc Imaging; 2009 May; 2(5):569-76. PubMed ID: 19442942
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Validation of contrast enhanced cine steady-state free precession and T2-weighted CMR for assessment of ischemic myocardial area-at-risk in the presence of reperfusion injury.
    Hansen ESS; Pedersen SF; Pedersen SB; Bøtker HE; Kim WY
    Int J Cardiovasc Imaging; 2019 Jun; 35(6):1039-1045. PubMed ID: 30852704
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Automatic segmentation of myocardium at risk from contrast enhanced SSFP CMR: validation against expert readers and SPECT.
    Tufvesson J; Carlsson M; Aletras AH; Engblom H; Deux JF; Koul S; Sörensson P; Pernow J; Atar D; Erlinge D; Arheden H; Heiberg E
    BMC Med Imaging; 2016 Mar; 16():19. PubMed ID: 26946139
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Myocardium at risk by magnetic resonance imaging: head-to-head comparison of T2-weighted imaging and contrast-enhanced steady-state free precession.
    Ubachs JF; Sörensson P; Engblom H; Carlsson M; Jovinge S; Pernow J; Arheden H
    Eur Heart J Cardiovasc Imaging; 2012 Dec; 13(12):1008-15. PubMed ID: 22645203
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of the myocardial area at risk: comparing T2-weighted cardiovascular magnetic resonance imaging with contrast-enhanced cine (CE-SSFP) imaging-a DANAMI3 substudy.
    Göransson C; Ahtarovski KA; Kyhl K; Lønborg J; Nepper-Christensen L; Bertelsen L; Ghotbi AA; Schoos MM; Køber L; Høfsten D; Helqvist S; Kelbæk H; Engstrøm T; Vejlstrup N
    Eur Heart J Cardiovasc Imaging; 2019 Mar; 20(3):361-366. PubMed ID: 30085055
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An echo-planar imaging sequence is superior to a steady-state free precession sequence for visual as well as quantitative assessment of cardiac magnetic resonance stress perfusion.
    Ahlander BM; Maret E; Brudin L; Starck SA; Engvall J
    Clin Physiol Funct Imaging; 2017 Jan; 37(1):52-61. PubMed ID: 26147785
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Infarct evolution in man studied in patients with first-time coronary occlusion in comparison to different species - implications for assessment of myocardial salvage.
    Hedström E; Engblom H; Frogner F; Aström-Olsson K; Ohlin H; Jovinge S; Arheden H
    J Cardiovasc Magn Reson; 2009 Sep; 11(1):38. PubMed ID: 19775428
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Correspondence between the 17-segment model and coronary arterial anatomy using contrast-enhanced cardiac magnetic resonance imaging.
    Ortiz-Pérez JT; Rodríguez J; Meyers SN; Lee DC; Davidson C; Wu E
    JACC Cardiovasc Imaging; 2008 May; 1(3):282-93. PubMed ID: 19356440
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The evaluation of an electrocardiographic myocardial ischemia acuteness score to predict the amount of myocardial salvage achieved by early percutaneous coronary intervention Clinical validation with myocardial perfusion single photon emission computed tomography and cardiac magnetic resonance.
    Engblom H; Strauss DG; Heden B; Hedström E; Jovinge S; Götberg M; Erlinge D; Wagner GS; Arheden H
    J Electrocardiol; 2011; 44(5):525-32. PubMed ID: 21658711
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Location of myocardium at risk in patients with first-time ST-elevation infarction: comparison among single photon emission computed tomography, magnetic resonance imaging, and electrocardiography.
    Ubachs JF; Engblom H; Hedström E; Selvester RH; Knippenberg SA; Wagner GS; Gorgels AP; Arheden H
    J Electrocardiol; 2009; 42(2):198-203. PubMed ID: 19100566
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cardiovascular magnetic resonance of the myocardium at risk in acute reperfused myocardial infarction: comparison of T2-weighted imaging versus the circumferential endocardial extent of late gadolinium enhancement with transmural projection.
    Ubachs JF; Engblom H; Erlinge D; Jovinge S; Hedström E; Carlsson M; Arheden H
    J Cardiovasc Magn Reson; 2010 Mar; 12(1):18. PubMed ID: 20350309
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Myocardial perfusion in patients with a totally occluded left anterior descending coronary artery reinjected by a normal right coronary artery: the role of collateral circulation.
    Chammas E; Hussein A; Ballane G; Helou A; Yatim A; Tarcha W; Ghanem G
    Angiology; 2008; 59(4):464-8. PubMed ID: 18388046
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Myocardial perfusion imaging based on the blood oxygen level-dependent effect using T2-prepared steady-state free-precession magnetic resonance imaging.
    Fieno DS; Shea SM; Li Y; Harris KR; Finn JP; Li D
    Circulation; 2004 Sep; 110(10):1284-90. PubMed ID: 15326062
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 41.