145 related articles for article (PubMed ID: 27418451)
1. Functional Duration of Closure Systems Used in Partial Nephrectomy.
Gupta R; Sunny N; Noyes SL; Tourojman M; Paka B; Bossemeyer R; Lane BR
J Urol; 2016 Nov; 196(5):1560-1565. PubMed ID: 27418451
[TBL] [Abstract][Full Text] [Related]
2. Holding Strength of a Hem-o-lok/Lapra-Ty Clip Combination on Sutures Used During Partial Nephrectomy.
Paka B; Bossemeyer R; Tourojman M; Gupta R; Lane BR
Urology; 2017 Sep; 107():138-143. PubMed ID: 28652162
[TBL] [Abstract][Full Text] [Related]
3. Comparison of holding strength of suture anchors on human renal capsule.
Tarin T; Kimm S; Chung B; Shinghal R; Reese J
J Endourol; 2010 Feb; 24(2):293-7. PubMed ID: 20050785
[TBL] [Abstract][Full Text] [Related]
4. New technique with combination of felt, Hem-o-lok and Lapra-Ty for suturing the renal parenchyma in laparoscopic partial nephrectomy.
Masumori N; Itoh N; Takahashi S; Kitamura H; Nishida S; Tsukamoto T
Int J Urol; 2012 Mar; 19(3):273-6. PubMed ID: 22168748
[TBL] [Abstract][Full Text] [Related]
5. Holding Strength of Suture: An Experimental Study Using Porcine Kidney.
Özkuvanci Ü; Akpinar H; Karadag MA; Dönmez Mİ; Altunrende F
JSLS; 2017; 21(3):. PubMed ID: 28729782
[TBL] [Abstract][Full Text] [Related]
6. Comparison of holding strength of suture anchors for hepatic and renal parenchyma.
Ames CD; Perrone JM; Frisella AJ; Morrissey K; Landman J
J Endourol; 2005 Dec; 19(10):1221-5. PubMed ID: 16359220
[TBL] [Abstract][Full Text] [Related]
7. Lapra-Ty holding strength and slippage with various suture types and sizes.
Weld KJ; Arzola J; Montiglio C; Bush AC; Cespedes RD
Urology; 2008 Jan; 71(1):32-5. PubMed ID: 18242360
[TBL] [Abstract][Full Text] [Related]
8. Absolok® versus Hem-o-Lok® clips for renorrhaphy during partial nephrectomy for parenchymal renal tumors.
Rossanese M; Crestani A; Giannarini G; Calandriello M; Alario G; Simonato A; Ficarra V
Minerva Urol Nefrol; 2020 Feb; 72(1):91-98. PubMed ID: 31833724
[TBL] [Abstract][Full Text] [Related]
9. Barbed suture for renorrhaphy during robot-assisted partial nephrectomy.
Sammon J; Petros F; Sukumar S; Bhandari A; Kaul S; Menon M; Rogers C
J Endourol; 2011 Mar; 25(3):529-33. PubMed ID: 21351886
[TBL] [Abstract][Full Text] [Related]
10. An experimental assessment of suture techniques using Lapra-ty clips through the laparoscope and a case report: laparoscopic closure using Lapra-ty for a perforation of the sigmoid colon.
Rino Y; Imada T; Ozawa Y; Iwasaki H; Tokunaga M; Morinaga S; Onodera S; Hatori S; Kato N; Takanashi Y
Hepatogastroenterology; 2002; 49(47):1281-3. PubMed ID: 12239924
[TBL] [Abstract][Full Text] [Related]
11. Application of the Hem-o-lok ligation system in laparoscopic nephrectomy.
Ping H; Xing NZ; Zhang JH; Yan Y; Kang N; Niu YN
Surg Endosc; 2010 Jun; 24(6):1494-7. PubMed ID: 20033713
[TBL] [Abstract][Full Text] [Related]
12. An ex-vivo evaluation of the application and strength of a novel laparoscopic knot substitute device.
Chi T; Eisner BH; Berger AD; Stoller ML
J Endourol; 2010 Jan; 24(1):95-8. PubMed ID: 19929424
[TBL] [Abstract][Full Text] [Related]
13. Routine vascular control using the Hem-o-lok clip in laparoscopic nephrectomy: animal study and clinical application.
Yip SK; Tan YH; Cheng C; Sim HG; Lee YM; Chee C
J Endourol; 2004 Feb; 18(1):77-81. PubMed ID: 15006060
[TBL] [Abstract][Full Text] [Related]
14. Hem-o-lok clips for vascular control during laparoscopic ablative nephrectomy: a single-center experience.
Kapoor R; Singh KJ; Suri A; Dubey D; Mandhani A; Srivastava A; Kumar A
J Endourol; 2006 Mar; 20(3):202-4. PubMed ID: 16548730
[TBL] [Abstract][Full Text] [Related]
15. Resorbable clip migration in the collecting system after laparoscopic partial nephrectomy.
Miller M; Anderson JK; Pearle MS; Cadeddu JA
Urology; 2006 Apr; 67(4):845.e7-8. PubMed ID: 16618571
[TBL] [Abstract][Full Text] [Related]
16. Ligation of uterine vessels in total laparoscopic hysterectomy using Hem-o-lok clips.
Lee JE; Kim KG; Lee DO; Seo SS; Kang S; Park SY; Lim MC
Taiwan J Obstet Gynecol; 2015 Feb; 54(1):8-12. PubMed ID: 25675912
[TBL] [Abstract][Full Text] [Related]
17. Experimental Studies of Nonabsorbable Polymeric Surgical Clips for Use in Urologic Laparoscopy.
Saki Z; Kallidonis P; Noureldin Y; Kotsiris D; Ntasiotis P; Adamou C; Vagionis A; Liatsikos E
J Endourol; 2019 Sep; 33(9):730-735. PubMed ID: 31266362
[No Abstract] [Full Text] [Related]
18. The Hem-o-lok clip is safe for laparoscopic nephrectomy: a multi-institutional review.
Ponsky L; Cherullo E; Moinzadeh A; Desai M; Kaouk J; Haber GP; Chen D; Ng C; Fuchs G; Singh D; Finelli A; Frank I; Matin S
Urology; 2008 Apr; 71(4):593-6. PubMed ID: 18295866
[TBL] [Abstract][Full Text] [Related]
19. Z-shaped running suture for outer layer renorrhaphy during robot-assisted partial nephrectomy.
Ambrosini F; Dell'oglio P; Palagonia E; Buratto C; Martiriggiano M; Barbieri M; Secco S; Olivero A; Terrone C; Bocciardi AM; Galfano A
Minerva Urol Nephrol; 2023 Apr; 75(2):217-222. PubMed ID: 36999838
[TBL] [Abstract][Full Text] [Related]
20. The single-knot method with Lapra-Ty clips is useful for training surgeons in vesicourethral anastomosis during laparoscopic radical prostatectomy.
Yasui T; Itoh Y; Maruyama T; Akita H; Hashimoto Y; Tozawa K; Kohri K
Int Urol Nephrol; 2009; 41(2):281-5. PubMed ID: 18568411
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]