BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1202 related articles for article (PubMed ID: 27424244)

  • 1. Aortic Angulation Attenuates Procedural Success Following Self-Expandable But Not Balloon-Expandable TAVR.
    Abramowitz Y; Maeno Y; Chakravarty T; Kazuno Y; Takahashi N; Kawamori H; Mangat G; Cheng W; Jilaihawi H; Makkar RR
    JACC Cardiovasc Imaging; 2016 Aug; 9(8):964-72. PubMed ID: 27424244
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Safety and Efficacy of Self-Expanding TAVR in Patients With Aortoventricular Angulation.
    Popma JJ; Reardon MJ; Yakubov SJ; Hermiller JB; Harrison JK; Gleason TG; Conte JV; Deeb GM; Chetcuti S; Oh JK; Boulware MJ; Huang J; Adams DH;
    JACC Cardiovasc Imaging; 2016 Aug; 9(8):973-81. PubMed ID: 27491485
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of aorto-ventricular angulation on procedural success in transcatheter aortic valve replacements with the Lotus Valve system.
    Rashid HN; McCormick LM; Talman AH; Ihdayhid AR; Nerlekar N; Amiruddin AS; Cameron J; Nasis A; Meredith IT; Gooley RP
    Catheter Cardiovasc Interv; 2018 Jun; 91(7):1365-1370. PubMed ID: 29210168
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Aortic annulus angulation does not attenuate procedural success of transcatheter aortic valve replacement using a novel self-expanding bioprosthesis.
    D'Ancona G; Kische S; El-Mawardy M; Dißmann M; Heinze H; Zohlnhöfer-Momm D; Gürer H; Ince H
    Heart Vessels; 2019 Dec; 34(12):1969-1975. PubMed ID: 31134380
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Complications after Transfemoral Transcatheter Aortic Valve Replacement with a Balloon-Expandable Prosthesis: The Importance of Preventative Measures and Contingency Planning.
    Chakravarty T; Jilaihawi H; Doctor N; Fontana G; Forrester JS; Cheng W; Makkar R
    Catheter Cardiovasc Interv; 2018 Apr; 91(5):E29-E42. PubMed ID: 23436313
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical and hemodynamic results after direct transcatheter aortic valve replacement versus pre-implantation balloon aortic valvuloplasty: A case-matched analysis.
    Ferrera C; Nombela-Franco L; Garcia E; Jimenez-Quevedo P; Biagioni C; Gonzalo N; Nuñez-Gil I; Viana-Tejedor A; Salinas P; Alberto de Agustin J; Almeria C; Islas F; Perez de Isla L; Fernandez-Perez C; Escaned J; Fernández-Ortiz A; Macaya C
    Catheter Cardiovasc Interv; 2017 Nov; 90(5):809-816. PubMed ID: 27515377
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of self-expanding and balloon-expandable transcatheter aortic valves morphology and association with paravalvular regurgitation: Evaluation using multidetector computed tomography.
    Almeida JG; Ferreira SM; Fonseca P; Dias T; Guerreiro C; Barbosa A; Teixeira P; Carvalho M; Ferreira W; Ferreira ND; Braga P; Ribeiro J; Ribeiro VG
    Catheter Cardiovasc Interv; 2018 Sep; 92(3):533-541. PubMed ID: 29105953
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Procedural and 30-day clinical outcomes following transcatheter aortic valve replacement with lotus valve: Results of the RELEVANT study.
    Montone RA; Testa L; Fraccaro C; Montorfano M; Castriota F; Nerla R; Angelillis M; Tusa M; Giannini F; Garatti A; Tarantini G; Petronio AS; Brambilla N; Bedogni F
    Catheter Cardiovasc Interv; 2017 Dec; 90(7):1206-1211. PubMed ID: 28145039
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Computed tomography (CT) assessment of the membranous septal anatomy prior to transcatheter aortic valve replacement (TAVR) with the balloon-expandable SAPIEN 3 valve.
    Oestreich BA; Mbai M; Gurevich S; Nijjar PS; Adabag S; Bertog S; Kelly R; Garcia S
    Cardiovasc Revasc Med; 2018; 19(5 Pt B):626-631. PubMed ID: 29352699
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of device-host interaction on paravalvular aortic regurgitation with different transcatheter heart valves.
    Rodríguez-Olivares R; El Faquir N; Rahhab Z; van Gils L; Ren B; Sakhi R; Geleijnse ML; van Domburg R; de Jaegere PPT; Zamorano Gómez JL; Van Mieghem NM
    Cardiovasc Revasc Med; 2019 Feb; 20(2):126-132. PubMed ID: 29779973
    [TBL] [Abstract][Full Text] [Related]  

  • 11. 5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves: Results From the CHOICE Randomized Clinical Trial.
    Abdel-Wahab M; Landt M; Neumann FJ; Massberg S; Frerker C; Kurz T; Kaur J; Toelg R; Sachse S; Jochheim D; Schäfer U; El-Mawardy M; Robinson DR; Richardt G;
    JACC Cardiovasc Interv; 2020 May; 13(9):1071-1082. PubMed ID: 32305398
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Balloon-expandable transcatheter aortic valve replacement in patients with extreme aortic valve calcification.
    Abramowitz Y; Jilaihawi H; Chakravarty T; Kashif M; Matar G; Hariri B; Patel J; Nakamura M; Cheng W; Makkar RR
    Catheter Cardiovasc Interv; 2016 May; 87(6):1173-9. PubMed ID: 26527374
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The Impact of Aortic Angulation on Contemporary Transcatheter Aortic Valve Replacement Outcomes.
    Medranda GA; Musallam A; Zhang C; Rappaport H; Gallino PE; Case BC; Satler LF; Ben-Dor I; Rogers T; Waksman R
    JACC Cardiovasc Interv; 2021 Jun; 14(11):1209-1215. PubMed ID: 34112456
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Impact of horizontal aorta on procedural and clinical outcomes in second-generation transcatheter aortic valve implantation.
    Di Stefano D; Colombo A; Mangieri A; Gallone G; Tzanis G; Laricchia A; Baldetti L; Palmisano A; Esposito A; Gallo F; Latib A; Montorfano M; Giannini F
    EuroIntervention; 2019 Oct; 15(9):e749-e756. PubMed ID: 31334701
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Highly Predictive Risk Model for Pacemaker Implantation After TAVR.
    Maeno Y; Abramowitz Y; Kawamori H; Kazuno Y; Kubo S; Takahashi N; Mangat G; Okuyama K; Kashif M; Chakravarty T; Nakamura M; Cheng W; Friedman J; Berman D; Makkar RR; Jilaihawi H
    JACC Cardiovasc Imaging; 2017 Oct; 10(10 Pt A):1139-1147. PubMed ID: 28412434
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prior Balloon Valvuloplasty Versus Direct Transcatheter Aortic Valve Replacement: Results From the DIRECTAVI Trial.
    Leclercq F; Robert P; Akodad M; Macia JC; Gandet T; Delseny D; Chettouh M; Schmutz L; Robert G; Levy G; Targosz F; Maupas E; Roubille F; Marin G; Nagot N; Albat B; Lattuca B; Cayla G
    JACC Cardiovasc Interv; 2020 Mar; 13(5):594-602. PubMed ID: 32139216
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Balloon Post-Dilation Following Implantation of a Self-Expanding Transcatheter Aortic Valve Bioprosthesis.
    Harrison JK; Hughes GC; Reardon MJ; Stoler R; Grayburn P; Hebeler R; Liu D; Chang Y; Popma JJ;
    JACC Cardiovasc Interv; 2017 Jan; 10(2):168-175. PubMed ID: 28104211
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of Acquired Thrombocytopenia According to the Balloon-Expandable Versus Self-Expandable Valves in Patients Undergoing Transcatheter Aortic Valve Replacement.
    Kisacik H; Tok D; Balci KG; Demirkan B; Karakurt M; Açar B; Karabulut Ö; Erbay I; Balci MM
    Angiology; 2021 Mar; 72(3):290-294. PubMed ID: 32873055
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Self-Expanding Transcatheter Aortic Valve Replacement Versus Surgical Valve Replacement in Patients at High Risk for Surgery: A Study of Echocardiographic Change and Risk Prediction.
    Little SH; Oh JK; Gillam L; Sengupta PP; Orsinelli DA; Cavalcante JL; Chang JD; Adams DH; Zorn GL; Pollak AW; Abdelmoneim SS; Reardon MJ; Qiao H; Popma JJ
    Circ Cardiovasc Interv; 2016 Jun; 9(6):. PubMed ID: 27313280
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves.
    Stähli BE; Nguyen-Kim TD; Gebhard C; Erhart L; Frauenfelder T; Tanner FC; Falk V; Landmesser U; Nietlispach F; Lüscher TF; Maier W; Binder RK
    J Heart Valve Dis; 2015 Jan; 24(1):10-21. PubMed ID: 26182615
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 61.