These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 2742952)

  • 1. Acute and chronic canine ex vivo blood interactions with NHLBI-DTB primary reference materials.
    McCoy TJ; Grasel TG; Okkema AZ; Cooper SL
    Biomaterials; 1989 May; 10(4):243-50. PubMed ID: 2742952
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A canine ex vivo shunt for isotopic hemocompatibility evaluation of a NHLBI DTB primary reference material and of a IUPAC reference material.
    Caix J; Janvier G; Legault B; Bordenave L; Rouais F; Basse-Cathalinat B; Baquey C
    J Biomater Sci Polym Ed; 1994; 5(4):279-91. PubMed ID: 8025027
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Platelet consumption by NHLBI reference materials and SILASTIC [corrected].
    Ip WF; Sefton MV
    J Biomed Mater Res; 1991 Oct; 25(10):1321-4. PubMed ID: 1812123
    [No Abstract]   [Full Text] [Related]  

  • 4. Surface modification with PEO-containing triblock copolymer for improved biocompatibility: in vitro and ex vivo studies.
    Kidane A; Lantz GC; Jo S; Park K
    J Biomater Sci Polym Ed; 1999; 10(10):1089-105. PubMed ID: 10591134
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of the in vitro and ex vivo blood compatibility of primary reference materials.
    Pelzer H; Heimburger N
    J Biomed Mater Res; 1986; 20(9):1401-9. PubMed ID: 3536934
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro vs. ex vivo platelet deposition on polymer surfaces.
    Goodman SL; Lelah MD; Lambrecht LK; Cooper SL; Albrecht RM
    Scan Electron Microsc; 1984; (Pt 1):279-90. PubMed ID: 6740230
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Surface and blood-contacting properties of alkylsiloxane monolayers supported on silicone rubber.
    Silver JH; Hergenrother RW; Lin JC; Lim F; Lin HB; Okada T; Chaudhury MK; Cooper SL
    J Biomed Mater Res; 1995 Apr; 29(4):535-48. PubMed ID: 7622539
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hemocompatibility, biocompatibility, inflammatory and in vivo studies of primary reference materials low-density polyethylene and polydimethylsiloxane: a review.
    BĂ©langer MC; Marois Y
    J Biomed Mater Res; 2001; 58(5):467-77. PubMed ID: 11505420
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Glow discharge plasma treatment of polyethylene tubing with tetraglyme results in ultralow fibrinogen adsorption and greatly reduced platelet adhesion.
    Cao L; Sukavaneshvar S; Ratner BD; Horbett TA
    J Biomed Mater Res A; 2006 Dec; 79(4):788-803. PubMed ID: 16883583
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vivo leucocyte interactions with the NHLBI-DTB primary reference materials: polyethylene and silica-free polydimethylsiloxane.
    Spilizewski KL; Marchant RE; Anderson JM; Hiltner A
    Biomaterials; 1987 Jan; 8(1):12-7. PubMed ID: 3030455
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A canine ex vivo series shunt for evaluating thrombus deposition on polymer surfaces.
    Lelah MD; Lambrecht LK; Cooper SL
    J Biomed Mater Res; 1984; 18(5):475-96. PubMed ID: 6736079
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Series shunt evaluation of polyurethane vascular graft materials in chronically AV-shunted canines.
    McCoy TJ; Wabers HD; Cooper SL
    J Biomed Mater Res; 1990 Jan; 24(1):107-29. PubMed ID: 2303499
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A simple method for ex vivo evaluation of biomaterial interaction with blood platelets.
    Mantovani F; Marconi W; Caprino L; Goglia G; Togna G
    Int J Artif Organs; 1980 Sep; 3(5):305-10. PubMed ID: 7461864
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The role of Fbg in platelet adhesion to polymeric materials in conditions of psychological stress.
    Lamponi S; Aloisi AM; Barbucci R
    Biomaterials; 1999 Oct; 20(19):1791-7. PubMed ID: 10509189
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characterization of transient platelet contacts on a polyvinyl alcohol hydrogel by video microscopy.
    Godo MN; Sefton MV
    Biomaterials; 1999 Jun; 20(12):1117-26. PubMed ID: 10382827
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The influence of preadsorbed canine von Willebrand factor, fibronectin and fibrinogen on ex vivo artificial surface-induced thrombosis.
    Lambrecht LK; Young BR; Stafford RE; Park K; Albrecht RM; Mosher DF; Cooper SL
    Thromb Res; 1986 Jan; 41(1):99-117. PubMed ID: 3485833
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Surface properties and blood compatibility of polyurethaneureas.
    Grasel TG; Cooper SL
    Biomaterials; 1986 Sep; 7(5):315-28. PubMed ID: 3778991
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Blood-contacting properties of polydimethylsiloxane polyurea-urethanes.
    Hergenrother RW; Yu XH; Cooper SL
    Biomaterials; 1994 Jun; 15(8):635-40. PubMed ID: 7948584
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Blood compatibility of surfaces modified by plasma polymerization.
    Yeh YS; Iriyama Y; Matsuzawa Y; Hanson SR; Yasuda H
    J Biomed Mater Res; 1988 Sep; 22(9):795-818. PubMed ID: 3220845
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Blood compatibility of hydrophilic polymers.
    Ikada Y; Iwata H; Horii F; Matsunaga T; Taniguchi M; Suzuki M; Taki W; Yamagata S; Yonekawa Y; Handa H
    J Biomed Mater Res; 1981 Sep; 15(5):697-718. PubMed ID: 12659136
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.