These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 27432751)

  • 1. Drug deposition in coronary arteries with overlapping drug-eluting stents.
    Rikhtegar F; Edelman ER; Olgac U; Poulikakos D; Kurtcuoglu V
    J Control Release; 2016 Sep; 238():1-9. PubMed ID: 27432751
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hemodynamics in coronary arteries with overlapping stents.
    Rikhtegar F; Wyss C; Stok KS; Poulikakos D; Müller R; Kurtcuoglu V
    J Biomech; 2014 Jan; 47(2):505-11. PubMed ID: 24275438
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling.
    LaDisa JF; Olson LE; Douglas HA; Warltier DC; Kersten JR; Pagel PS
    Biomed Eng Online; 2006 Jun; 5():40. PubMed ID: 16780592
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Strut position, blood flow, and drug deposition: implications for single and overlapping drug-eluting stents.
    Balakrishnan B; Tzafriri AR; Seifert P; Groothuis A; Rogers C; Edelman ER
    Circulation; 2005 Jun; 111(22):2958-65. PubMed ID: 15927969
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Localized Hemodynamics of Drug-Eluting Stents Are Not Improved by the Presence of Magnetic Struts.
    Vijayaratnam PR; Barber TJ; Reizes JA
    J Biomech Eng; 2017 Jan; 139(1):. PubMed ID: 27893059
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Overlapping paclitaxel-eluting stents: long-term effects in a porcine coronary artery model.
    Wilson GJ; Polovick JE; Huibregtse BA; Poff BC
    Cardiovasc Res; 2007 Nov; 76(2):361-72. PubMed ID: 17716637
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Stent thrombogenicity early in high-risk interventional settings is driven by stent design and deployment and protected by polymer-drug coatings.
    Kolandaivelu K; Swaminathan R; Gibson WJ; Kolachalama VB; Nguyen-Ehrenreich KL; Giddings VL; Coleman L; Wong GK; Edelman ER
    Circulation; 2011 Apr; 123(13):1400-9. PubMed ID: 21422389
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents.
    Guagliumi G; Musumeci G; Sirbu V; Bezerra HG; Suzuki N; Fiocca L; Matiashvili A; Lortkipanidze N; Trivisonno A; Valsecchi O; Biondi-Zoccai G; Costa MA;
    JACC Cardiovasc Interv; 2010 May; 3(5):531-9. PubMed ID: 20488410
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Coronary Artery Stenting Affects Wall Shear Stress Topological Skeleton.
    Chiastra C; Mazzi V; Lodi Rizzini M; Calò K; Corti A; Acquasanta A; De Nisco G; Belliggiano D; Cerrato E; Gallo D; Morbiducci U
    J Biomech Eng; 2022 Jun; 144(6):. PubMed ID: 35015058
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The short-term effect on restenosis and thrombosis of a cobalt-chromium stent eluting two drugs in a porcine coronary artery model.
    Huang Y; Venkatraman SS; Boey FY; Umashankar PR; Mohanty M; Arumugam S
    J Interv Cardiol; 2009 Oct; 22(5):466-78. PubMed ID: 19627432
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Rationale and study design of the OISTER trial: optical coherence tomography evaluation of stent struts re-endothelialization in patients with non-ST-elevation acute coronary syndromes--a comparison of the intrEpide tRapidil eluting stent vs. taxus drug-eluting stent implantation.
    Iaccarino D; Politi L; Rossi R; Sgura F; Monopoli D; Modena MG; Sangiorgi GM
    J Cardiovasc Med (Hagerstown); 2010 Jul; 11(7):536-43. PubMed ID: 20090547
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of endothelium, stent design and deployment on the nitric oxide transport in stented artery: a potential role in stent restenosis and thrombosis.
    Liu X; Wang M; Zhang N; Fan Z; Fan Y; Deng X
    Med Biol Eng Comput; 2015 May; 53(5):427-39. PubMed ID: 25715753
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Luminal flow patterns dictate arterial drug deposition in stent-based delivery.
    Kolachalama VB; Tzafriri AR; Arifin DY; Edelman ER
    J Control Release; 2009 Jan; 133(1):24-30. PubMed ID: 18926864
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intravascular drug release kinetics dictate arterial drug deposition, retention, and distribution.
    Balakrishnan B; Dooley JF; Kopia G; Edelman ER
    J Control Release; 2007 Nov; 123(2):100-8. PubMed ID: 17868948
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intracoronary optical coherence tomography and histology of overlapping everolimus-eluting bioresorbable vascular scaffolds in a porcine coronary artery model: the potential implications for clinical practice.
    Farooq V; Serruys PW; Heo JH; Gogas BD; Onuma Y; Perkins LE; Diletti R; Radu MD; Räber L; Bourantas CV; Zhang Y; van Remortel E; Pawar R; Rapoza RJ; Powers JC; van Beusekom HM; Garcìa-Garcìa HM; Virmani R
    JACC Cardiovasc Interv; 2013 May; 6(5):523-32. PubMed ID: 23702016
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Numerical simulation on the effects of drug-eluting stents with different bending angles on hemodynamics and drug distribution.
    Chen Y; Xiong Y; Jiang W; Wong MS; Yan F; Wang Q; Fan Y
    Med Biol Eng Comput; 2016 Dec; 54(12):1859-1870. PubMed ID: 27048391
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Time-dependent 3D simulations of the hemodynamics in a stented coronary artery.
    Faik I; Mongrain R; Leask RL; Rodes-Cabau J; Larose E; Bertrand O
    Biomed Mater; 2007 Mar; 2(1):S28-37. PubMed ID: 18458417
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [The role of haemodynamic factors in the development of in-stent restenosis].
    Wasilewski J; Osadnik T; Peryt Stawiarska S; Poloński L
    Kardiol Pol; 2012; 70(11):1194-8. PubMed ID: 23180536
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening.
    LaDisa JF; Olson LE; Hettrick DA; Warltier DC; Kersten JR; Pagel PS
    Biomed Eng Online; 2005 Oct; 4():59. PubMed ID: 16250918
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Recent progress in percutaneous coronary intervention: evolution of the drug-eluting stents, focus on the XIENCE V drug-eluting stent.
    Doostzadeh J; Clark LN; Bezenek S; Pierson W; Sood PR; Sudhir K
    Coron Artery Dis; 2010 Jan; 21(1):46-56. PubMed ID: 19952925
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.