These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 27438176)

  • 1. Impact of Laparoscopic Lens Contamination in Operating Theaters: A Study on the Frequency and Duration of Lens Contamination and Commonly Utilized Techniques to Maintain Clear Vision.
    Yong N; Grange P; Eldred-Evans D
    Surg Laparosc Endosc Percutan Tech; 2016 Aug; 26(4):286-9. PubMed ID: 27438176
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Easy cleaning of the scope's lens in a syringe to prevent condensation during laparoscopic surgery.
    Runia AJ; Zengerink JF; Mannaerts GH
    Surg Endosc; 2009 Dec; 23(12):2849-50. PubMed ID: 19707825
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Efficacy of using a novel endoscopic lens cleaning device: a prospective randomized controlled trial.
    Cassera MA; Goers TA; Spaun GO; Swanström LL
    Surg Innov; 2011 Jun; 18(2):150-5. PubMed ID: 21343172
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Constant high-level visual acuity during total laparoscopic hysterectomy using the OpClear
    Evans R; Taylor A
    J Obstet Gynaecol; 2024 Dec; 44(1):2375590. PubMed ID: 39039900
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A novel one-step lens cleaning device using air and water flow for endoscopic surgery.
    Tatsuki H; Yokobori T; Katayama C; Kato R; Takahashi R; Osone K; Takada T; Yajima R; Motegi Y; Ogawa H; Fujii T; Shirabe K; Kuwano H; Asao T
    PLoS One; 2018; 13(7):e0200749. PubMed ID: 30020986
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantitative assessment of the troCarWash™ system for automated laparoscopic camera cleaning.
    Ahmed M; Gowda A; Alavi Naini F; Le A; Treffalls J; Torres R; Burt BM
    Surg Endosc; 2024 Jun; 38(6):3470-3477. PubMed ID: 38769187
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prospective, randomized comparison of the use of FloShield Air System
    Bendifallah S; Salakos E; Naoura I; Aristizabal P; Furet E; Zilberman S; Ballester M; Darai E
    Surg Endosc; 2018 Mar; 32(3):1593-1599. PubMed ID: 28643058
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Quantifying Intraoperative Laparoscopic Visual Field Opacity.
    Abbitt D; Khallouq BB; Redan J
    JSLS; 2017; 21(2):. PubMed ID: 28584499
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impaired robotic surgical visualization: archaic issues in a modern operating room.
    Venkatayogi N; Parker M; Uecker J; Laviana AA; Cohen A; Belbina SH; Gereta S; Ancha N; Ravi S; Idelson C; Alambeigi F
    J Robot Surg; 2023 Dec; 17(6):2875-2880. PubMed ID: 37804395
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Laparoscopic lens fogging: solving a common surgical problem in standard and robotic laparoscopes via a scientific model.
    Manning TG; Papa N; Perera M; McGrath S; Christidis D; Khan M; O'Beirne R; Campbell N; Bolton D; Lawrentschuk N
    Surg Endosc; 2018 Mar; 32(3):1600-1606. PubMed ID: 28791559
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Laparoscopic lens fogging: a review of etiology and methods to maintain a clear visual field.
    Lawrentschuk N; Fleshner NE; Bolton DM
    J Endourol; 2010 Jun; 24(6):905-13. PubMed ID: 20370436
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Povidone-iodine surgical scrub solution prevents fogging of the scope's lens during laparoscopic surgery.
    Mohammadhosseini B
    Surg Endosc; 2010 Jun; 24(6):1498-9; author reply 1500. PubMed ID: 20033719
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Elimination of laparoscopic lens fogging using directional flow of CO2.
    Calhoun JT; Redan JA
    JSLS; 2014; 18(1):55-61. PubMed ID: 24680144
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effectiveness of Heated Sterile Water vs ResoClear
    Merkx R; Muselaers C; d'Ancona F; Warlé M; van der Jagt M; Kusters A; Poyck P; Schulte R; Langenhuijsen J
    J Endourol; 2018 Jan; 32(1):54-58. PubMed ID: 29186976
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Interventional evaluation of environmental contamination by vancomycin-resistant enterococci: failure of personnel, product, or procedure?
    Hota B; Blom DW; Lyle EA; Weinstein RA; Hayden MK
    J Hosp Infect; 2009 Feb; 71(2):123-31. PubMed ID: 19108932
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Easy cleaning of the camera port during laparoscopic surgery: three practical techniques.
    Theeuwes H; Zengerink H; Mannaerts G
    J Laparoendosc Adv Surg Tech A; 2011 Nov; 21(9):821-2. PubMed ID: 21978252
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cleaning the laparoscopic camera port by a microbiology culture swab.
    Alhamdani A; Abbas A; Mahmud S; Baker A
    J Laparoendosc Adv Surg Tech A; 2008 Oct; 18(5):751-2. PubMed ID: 18699751
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Early Experience With a Novel Super-Hydrophilic Laparoscopic Scope Cleaning Device and Narrative Review of Available Cleaning Strategies.
    Spurzem GJ; Broderick RC; Cota PR; Sandler BJ; Jacobsen GR; Horgan S
    Surg Innov; 2024 Dec; 31(6):598-604. PubMed ID: 39218621
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effective cleaning of endoscopic lenses to achieve visual clarity for minimally invasive abdominopelvic surgery: a systematic review.
    Nabeel A; Al-Sabah SK; Ashrafian H
    Surg Endosc; 2022 Apr; 36(4):2382-2392. PubMed ID: 33963440
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of a warming bath to prevent lens fogging during laparoscopy.
    Brown JA; Inocencio MD; Sundaram CP
    J Endourol; 2008 Nov; 22(11):2413-4. PubMed ID: 19046081
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.