These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
346 related articles for article (PubMed ID: 27444926)
1. Ultrasound-guided breast-conserving surgery for early-stage palpable and nonpalpable invasive breast cancer: decreased excision volume at unchanged tumor-free resection margin. Slijkhuis WA; Noorda EM; van der Zaag-Loonen H; Eenennaam MJ; Greve KE; Lastdrager WB; Gratama JW Breast Cancer Res Treat; 2016 Aug; 158(3):535-41. PubMed ID: 27444926 [TBL] [Abstract][Full Text] [Related]
2. Intraoperative ultrasound guidance for palpable breast cancer excision (COBALT trial): a multicentre, randomised controlled trial. Krekel NM; Haloua MH; Lopes Cardozo AM; de Wit RH; Bosch AM; de Widt-Levert LM; Muller S; van der Veen H; Bergers E; de Lange de Klerk ES; Meijer S; van den Tol MP Lancet Oncol; 2013 Jan; 14(1):48-54. PubMed ID: 23218662 [TBL] [Abstract][Full Text] [Related]
3. Surgeon performed continuous intraoperative ultrasound guidance decreases re-excisions and mastectomy rates in breast cancer. Karadeniz Cakmak G; Emre AU; Tascilar O; Bahadir B; Ozkan S Breast; 2017 Jun; 33():23-28. PubMed ID: 28273552 [TBL] [Abstract][Full Text] [Related]
4. Ultrasound-guided breast-sparing surgery to improve cosmetic outcomes and quality of life. A prospective multicentre randomised controlled clinical trial comparing ultrasound-guided surgery to traditional palpation-guided surgery (COBALT trial). Krekel NM; Zonderhuis BM; Schreurs HW; Cardozo AM; Rijna H; van der Veen H; Muller S; Poortman P; de Widt L; de Roos WK; Bosch AM; Taets van Amerongen AH; Bergers E; van der Linden MH; de Lange de Klerk ES; Winters HA; Meijer S; van den Tol PM BMC Surg; 2011 Mar; 11():8. PubMed ID: 21410949 [TBL] [Abstract][Full Text] [Related]
5. Comparison of outcomes of surgeon-performed intraoperative ultrasonography-guided wire localization and preoperative wire localization in nonpalpable breast cancer patients undergoing breast-conserving surgery: A retrospective cohort study. Shin YD; Choi YJ; Kim DH; Park SS; Choi H; Kim DJ; Park S; Yun HY; Song YJ Medicine (Baltimore); 2017 Dec; 96(50):e9340. PubMed ID: 29390405 [TBL] [Abstract][Full Text] [Related]
6. [Breast-conserving surgery for breast cancer: still much to be gained]. Krekel NM; Haloua MH; Muller S; Bergers E; Rietveld DH; Meijers S; van den Tol MP Ned Tijdschr Geneeskd; 2012; 156(29):A3573. PubMed ID: 22831490 [TBL] [Abstract][Full Text] [Related]
7. Ultrasound-Guided Versus Wire-Guided Breast-Conserving Surgery for Nonpalpable Breast Cancer. Eggemann H; Costa SD; Ignatov A Clin Breast Cancer; 2016 Feb; 16(1):e1-6. PubMed ID: 26439275 [TBL] [Abstract][Full Text] [Related]
8. Ultrasonography-guided breast-conserving surgery is superior to palpation-guided surgery for palpable breast cancer. Eggemann H; Ignatov T; Beni A; Costa SD; Ignatov A Clin Breast Cancer; 2014 Feb; 14(1):40-5. PubMed ID: 24169374 [TBL] [Abstract][Full Text] [Related]
9. A comparative study of perioperative techniques to attain negative margins and spare healthy breast tissue in breast conserving surgery. Krishna KL; Srinath BS; Santosh D; Velusamy S; Divyamala KP; Sariya Mohammadi J; Kurpad V; Kulkarni S; Yaji P; Goud S; Dhanireddy S; Ram J Breast Dis; 2020; 39(3-4):127-135. PubMed ID: 32831188 [TBL] [Abstract][Full Text] [Related]
10. A comparison of three methods for nonpalpable breast cancer excision. Krekel NM; Zonderhuis BM; Stockmann HB; Schreurs WH; van der Veen H; de Lange de Klerk ES; Meijer S; van den Tol MP Eur J Surg Oncol; 2011 Feb; 37(2):109-15. PubMed ID: 21194880 [TBL] [Abstract][Full Text] [Related]
11. Use of an intraoperative ultrasonography-guided localization and tissue fixation device demonstrates less margin positivity during breast-conserving surgery for invasive breast cancer than standard preoperative needle-wire localization: a retrospective comparative analysis in a consecutively treated case series. Povoski SP; Jimenez RE; Wang WP Clin Breast Cancer; 2014 Feb; 14(1):46-52. PubMed ID: 24176781 [TBL] [Abstract][Full Text] [Related]
12. Should we abandon wire-guided localization for nonpalpable breast cancer? A plea for wire-guided localization. de Roos MA; Welvaart WN; Ong KH Scand J Surg; 2013; 102(2):106-9. PubMed ID: 23820686 [TBL] [Abstract][Full Text] [Related]
13. Indocyanine Green Fluorescence-Guided Lumpectomy of Nonpalpable Breast Cancer Versus Ultrasound-Guided Excision. Guo W; Ji W; Zhang T; Xing Z; Xing F Surg Innov; 2022 Oct; 29(5):573-578. PubMed ID: 35225072 [TBL] [Abstract][Full Text] [Related]
14. Optimising surgical accuracy in palpable breast cancer with intra-operative breast ultrasound--feasibility and surgeons' learning curve. Krekel NM; Lopes Cardozo AM; Muller S; Bergers E; Meijer S; van den Tol MP Eur J Surg Oncol; 2011 Dec; 37(12):1044-50. PubMed ID: 21924854 [TBL] [Abstract][Full Text] [Related]
15. Radio-guided vs clip-guided localization of nonpalpable mass-like lesions of the breast from a screened population: A propensity score-matched study. Corsi F; Bossi D; Combi F; Papadopoulou O; Amadori R; Regolo L; Trifirò G; Albasini S; Mazzucchelli S; Sorrentino L J Surg Oncol; 2019 Jun; 119(7):916-924. PubMed ID: 30742309 [TBL] [Abstract][Full Text] [Related]
16. Intraoperative ultrasound reduces the need for re-excision in breast-conserving surgery. Karanlik H; Ozgur I; Sahin D; Fayda M; Onder S; Yavuz E World J Surg Oncol; 2015 Nov; 13():321. PubMed ID: 26596699 [TBL] [Abstract][Full Text] [Related]
17. Low re-excision rate for positive margins in patients treated with ultrasound-guided breast-conserving surgery. Yu CC; Chiang KC; Kuo WL; Shen SC; Lo YF; Chen SC Breast; 2013 Oct; 22(5):698-702. PubMed ID: 23333255 [TBL] [Abstract][Full Text] [Related]
18. Optimization of Wire-guided Technique With Bracketing Reduces Resection Volumes in Breast-conserving Surgery for Early Breast Cancer. Civil YA; Duvivier KM; Perin P; Baan AH; van der Velde S Clin Breast Cancer; 2020 Dec; 20(6):e749-e756. PubMed ID: 32653472 [TBL] [Abstract][Full Text] [Related]
19. A decade of intraoperative ultrasound guided breast conservation for margin negative resection - Radioactive, and magnetic, and Infrared Oh My…. Layeequr Rahman R; Puckett Y; Habrawi Z; Crawford S Am J Surg; 2020 Dec; 220(6):1410-1416. PubMed ID: 32958157 [TBL] [Abstract][Full Text] [Related]
20. Excessive resections in breast-conserving surgery: a retrospective multicentre study. Krekel N; Zonderhuis B; Muller S; Bril H; van Slooten HJ; de Lange de Klerk E; van den Tol P; Meijer S Breast J; 2011; 17(6):602-9. PubMed ID: 22050281 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]