These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 27448200)

  • 1. Detection of electron magnetic circular dichroism signals under zone axial diffraction geometry.
    Song D; Rusz J; Cai J; Zhu J
    Ultramicroscopy; 2016 Oct; 169():44-54. PubMed ID: 27448200
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of the asymmetry of dynamical electron diffraction on intensity of acquired EMCD signals.
    Song D; Wang Z; Zhu J
    Ultramicroscopy; 2015 Jan; 148():42-51. PubMed ID: 25261842
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A general way for quantitative magnetic measurement by transmitted electrons.
    Song D; Li G; Cai J; Zhu J
    Sci Rep; 2016 Jan; 6():18489. PubMed ID: 26726959
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Signal enhancement of electron magnetic circular dichroism by ultra-high-voltage TEM, toward quantitative nano-magnetism measurements.
    Tatsumi K; Muto S; Rusz J; Kudo T; Arai S
    Microscopy (Oxf); 2014 Jun; 63(3):243-7. PubMed ID: 24503161
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of dynamic diffraction conditions on magnetic parameter determination in a double perovskite Sr
    Wang ZC; Zhong XY; Jin L; Chen XF; Moritomo Y; Mayer J
    Ultramicroscopy; 2017 May; 176():212-217. PubMed ID: 28089306
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantitative characterization of nanoscale polycrystalline magnets with electron magnetic circular dichroism.
    Muto S; Rusz J; Tatsumi K; Adam R; Arai S; Kocevski V; Oppeneer PM; Bürgler DE; Schneider CM
    Nat Commun; 2014; 5():3138. PubMed ID: 24451994
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simultaneous mapping of EMCD signals and crystal orientations in a transmission electron microscope.
    Ali H; Rusz J; Warnatz T; Hjörvarsson B; Leifer K
    Sci Rep; 2021 Jan; 11(1):2180. PubMed ID: 33500427
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reciprocal and real space maps for EMCD experiments.
    Lidbaum H; Rusz J; Rubino S; Liebig A; Hjörvarsson B; Oppeneer PM; Eriksson O; Leifer K
    Ultramicroscopy; 2010 Oct; 110(11):1380-9. PubMed ID: 20692100
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Electron vortex beams prepared by a spiral aperture with the goal to measure EMCD on ferromagnetic films via STEM.
    Pohl D; Schneider S; Rusz J; Rellinghaus B
    Ultramicroscopy; 2015 Mar; 150():16-22. PubMed ID: 25497492
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prospect for measuring two-dimensional van der Waals magnets by electron magnetic chiral dichroism.
    Song D; Zheng F; Dunin-Borkowski RE
    Ultramicroscopy; 2022 Apr; 234():113476. PubMed ID: 35114564
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Single-pass STEM-EMCD on a zone axis using a patterned aperture: progress in experimental and data treatment methods.
    Thersleff T; Schönström L; Tai CW; Adam R; Bürgler DE; Schneider CM; Muto S; Rusz J
    Sci Rep; 2019 Dec; 9(1):18170. PubMed ID: 31796786
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Detection of magnetic circular dichroism using a transmission electron microscope.
    Schattschneider P; Rubino S; Hébert C; Rusz J; Kunes J; Novák P; Carlino E; Fabrizioli M; Panaccione G; Rossi G
    Nature; 2006 May; 441(7092):486-8. PubMed ID: 16724061
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimal aperture sizes and positions for EMCD experiments.
    Verbeeck J; Hébert C; Rubino S; Novák P; Rusz J; Houdellier F; Gatel C; Schattschneider P
    Ultramicroscopy; 2008 Aug; 108(9):865-72. PubMed ID: 18423875
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quantitative EMCD by use of a double aperture for simultaneous acquisition of EELS.
    Ali H; Warnatz T; Xie L; Hjörvarsson B; Leifer K
    Ultramicroscopy; 2019 Jan; 196():192-196. PubMed ID: 30439606
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Magnetic measurements with atomic-plane resolution.
    Rusz J; Muto S; Spiegelberg J; Adam R; Tatsumi K; Bürgler DE; Oppeneer PM; Schneider CM
    Nat Commun; 2016 Aug; 7():12672. PubMed ID: 27578421
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Noise-dependent bias in quantitative STEM-EMCD experiments revealed by bootstrapping.
    Ali H; Rusz J; Bürgler DE; Adam R; Schneider CM; Tai CW; Thersleff T
    Ultramicroscopy; 2024 Mar; 257():113891. PubMed ID: 38043363
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Parameter-free extraction of EMCD from an energy-filtered diffraction datacube using multivariate curve resolution.
    Muto S; Tatsumi K; Rusz J
    Ultramicroscopy; 2013 Feb; 125():89-96. PubMed ID: 23237771
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Achieving atomic resolution magnetic dichroism by controlling the phase symmetry of an electron probe.
    Rusz J; Idrobo JC; Bhowmick S
    Phys Rev Lett; 2014 Oct; 113(14):145501. PubMed ID: 25325649
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Single scan STEM-EMCD in 3-beam orientation using a quadruple aperture.
    Ali H; Sathyanath SKM; Tai CW; Rusz J; Uusimaki T; Hjörvarsson B; Thersleff T; Leifer K
    Ultramicroscopy; 2023 Sep; 251():113760. PubMed ID: 37285614
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An in-plane magnetic chiral dichroism approach for measurement of intrinsic magnetic signals using transmitted electrons.
    Song D; Tavabi AH; Li ZA; Kovács A; Rusz J; Huang W; Richter G; Dunin-Borkowski RE; Zhu J
    Nat Commun; 2017 May; 8():15348. PubMed ID: 28504267
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.