These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 27448630)

  • 1. A model for hepatic fibrosis: the competing effects of cell loss and iron on shortened modified Look-Locker inversion recovery T
    Tunnicliffe EM; Banerjee R; Pavlides M; Neubauer S; Robson MD
    J Magn Reson Imaging; 2017 Feb; 45(2):450-462. PubMed ID: 27448630
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold.
    Piechnik SK; Ferreira VM; Dall'Armellina E; Cochlin LE; Greiser A; Neubauer S; Robson MD
    J Cardiovasc Magn Reson; 2010 Nov; 12(1):69. PubMed ID: 21092095
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy, precision, and reproducibility of four T1 mapping sequences: a head-to-head comparison of MOLLI, ShMOLLI, SASHA, and SAPPHIRE.
    Roujol S; Weingärtner S; Foppa M; Chow K; Kawaji K; Ngo LH; Kellman P; Manning WJ; Thompson RB; Nezafat R
    Radiology; 2014 Sep; 272(3):683-9. PubMed ID: 24702727
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mapping tissue water T
    Mozes FE; Tunnicliffe EM; Moolla A; Marjot T; Levick CK; Pavlides M; Robson MD
    NMR Biomed; 2019 Feb; 32(2):e4030. PubMed ID: 30462873
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of fat on liver T1 measurements using modified Look-Locker inversion recovery (MOLLI) methods at 3T.
    Mozes FE; Tunnicliffe EM; Pavlides M; Robson MD
    J Magn Reson Imaging; 2016 Jul; 44(1):105-11. PubMed ID: 26762615
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of MOLLI and ShMOLLI in Terms of T1 Reactivity and the Relationship between T1 Reactivity and Conventional Signs of Response during Adenosine Stress Perfusion CMR.
    Gezmiş E; Peebles C; Flett A; Abbas A; Harden S; Shambrook J
    Balkan Med J; 2020 Aug; 37(5):260-268. PubMed ID: 32319279
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Noncontrast myocardial T1 mapping using cardiovascular magnetic resonance for iron overload.
    Sado DM; Maestrini V; Piechnik SK; Banypersad SM; White SK; Flett AS; Robson MD; Neubauer S; Ariti C; Arai A; Kellman P; Yamamura J; Schoennagel BP; Shah F; Davis B; Trompeter S; Walker M; Porter J; Moon JC
    J Magn Reson Imaging; 2015 Jun; 41(6):1505-11. PubMed ID: 25104503
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A study of T₁ relaxation time as a measure of liver fibrosis and the influence of confounding histological factors.
    Hoad CL; Palaniyappan N; Kaye P; Chernova Y; James MW; Costigan C; Austin A; Marciani L; Gowland PA; Guha IN; Francis ST; Aithal GP
    NMR Biomed; 2015 Jun; 28(6):706-14. PubMed ID: 25908098
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantitative assessment of hepatic function: modified look-locker inversion recovery (MOLLI) sequence for T1 mapping on Gd-EOB-DTPA-enhanced liver MR imaging.
    Yoon JH; Lee JM; Paek M; Han JK; Choi BI
    Eur Radiol; 2016 Jun; 26(6):1775-82. PubMed ID: 26373756
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Myocardial T1 mapping at 3.0 tesla using an inversion recovery spoiled gradient echo readout and bloch equation simulation with slice profile correction (BLESSPC) T1 estimation algorithm.
    Shao J; Rapacchi S; Nguyen KL; Hu P
    J Magn Reson Imaging; 2016 Feb; 43(2):414-25. PubMed ID: 26214152
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hydration and glycogen affect T
    Mózes FE; Valkovič L; Pavlides M; Robson MD; Tunnicliffe EM
    NMR Biomed; 2021 Jul; 34(7):e4530. PubMed ID: 33951228
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of MOLLI, shMOLLLI, and SASHA in discrimination between health and disease and relationship with histologically derived collagen volume fraction.
    Child N; Suna G; Dabir D; Yap ML; Rogers T; Kathirgamanathan M; Arroyo-Ucar E; Hinojar R; Mahmoud I; Young C; Wendler O; Mayr M; Sandhu B; Morton G; Muhly-Reinholz M; Dimmeler S; Nagel E; Puntmann VO
    Eur Heart J Cardiovasc Imaging; 2018 Jul; 19(7):768-776. PubMed ID: 29237044
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Application of texture analysis on parametric T
    Yu H; Touret AS; Li B; O'Brien M; Qureshi MM; Soto JA; Jara H; Anderson SW
    J Magn Reson Imaging; 2017 Jan; 45(1):250-259. PubMed ID: 27249625
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of T2, T1rho, and diffusion metrics in assessment of liver fibrosis in rats.
    Zhang H; Yang Q; Yu T; Chen X; Huang J; Tan C; Liang B; Guo H
    J Magn Reson Imaging; 2017 Mar; 45(3):741-750. PubMed ID: 27527587
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fast myocardial T
    Huang L; Neji R; Nazir MS; Whitaker J; Reid F; Bosio F; Chiribiri A; Razavi R; Roujol S
    J Magn Reson Imaging; 2019 Aug; 50(2):641-654. PubMed ID: 30672041
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Normal variation of magnetic resonance T1 relaxation times in the human population at 1.5 T using ShMOLLI.
    Piechnik SK; Ferreira VM; Lewandowski AJ; Ntusi NA; Banerjee R; Holloway C; Hofman MB; Sado DM; Maestrini V; White SK; Lazdam M; Karamitsos T; Moon JC; Neubauer S; Leeson P; Robson MD
    J Cardiovasc Magn Reson; 2013 Jan; 15(1):13. PubMed ID: 23331520
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Incremental value of quantitative CMR including parametric mapping for the diagnosis of acute myocarditis.
    Luetkens JA; Homsi R; Sprinkart AM; Doerner J; Dabir D; Kuetting DL; Block W; Andrié R; Stehning C; Fimmers R; Gieseke J; Thomas DK; Schild HH; Naehle CP
    Eur Heart J Cardiovasc Imaging; 2016 Feb; 17(2):154-61. PubMed ID: 26476398
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Systolic ShMOLLI myocardial T1-mapping for improved robustness to partial-volume effects and applications in tachyarrhythmias.
    Ferreira VM; Wijesurendra RS; Liu A; Greiser A; Casadei B; Robson MD; Neubauer S; Piechnik SK
    J Cardiovasc Magn Reson; 2015 Aug; 17(1):77. PubMed ID: 26315682
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Accuracy, precision, and reproducibility of myocardial T1 mapping: A comparison of four T1 estimation algorithms for modified look-locker inversion recovery (MOLLI).
    Shao J; Liu D; Sung K; Nguyen KL; Hu P
    Magn Reson Med; 2017 Nov; 78(5):1746-1756. PubMed ID: 27917529
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Native Myocardial T1 Mapping, Are We There Yet?
    Hamdy A; Kitagawa K; Ishida M; Sakuma H
    Int Heart J; 2016 Jul; 57(4):400-7. PubMed ID: 27396560
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.