These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 27448630)

  • 21. T1- and ECV-mapping in clinical routine at 3 T: differences between MOLLI, ShMOLLI and SASHA.
    Heidenreich JF; Weng AM; Donhauser J; Greiser A; Chow K; Nordbeck P; Bley TA; Köstler H
    BMC Med Imaging; 2019 Aug; 19(1):59. PubMed ID: 31370821
    [TBL] [Abstract][Full Text] [Related]  

  • 22. BLOCH equations-based reconstruction of myocardium t1 maps from modified look-locker inversion recovery sequence.
    Marty B; Vignaud A; Greiser A; Robert B; de Sousa PL; Carlier PG
    PLoS One; 2015; 10(5):e0126766. PubMed ID: 25962182
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Detection of elevated right ventricular extracellular volume in pulmonary hypertension using Accelerated and Navigator-Gated Look-Locker Imaging for Cardiac T1 Estimation (ANGIE) cardiovascular magnetic resonance.
    Mehta BB; Auger DA; Gonzalez JA; Workman V; Chen X; Chow K; Stump CJ; Mazimba S; Kennedy JL; Gay E; Salerno M; Kramer CM; Epstein FH; Bilchick KC
    J Cardiovasc Magn Reson; 2015 Dec; 17():110. PubMed ID: 26692265
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of liver T1 relaxation times without and with iron correction in pediatric autoimmune liver disease.
    Dillman JR; Serai SD; Miethke AG; Singh R; Tkach JA; Trout AT
    Pediatr Radiol; 2020 Jun; 50(7):935-942. PubMed ID: 32409910
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Instantaneous signal loss simulation (InSiL): an improved algorithm for myocardial T₁ mapping using the MOLLI sequence.
    Shao J; Nguyen KL; Natsuaki Y; Spottiswoode B; Hu P
    J Magn Reson Imaging; 2015 Mar; 41(3):721-9. PubMed ID: 24677371
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Assessment of liver fibrosis using pharmacokinetic parameters of dynamic contrast-enhanced magnetic resonance imaging.
    Li Z; Sun J; Chen L; Huang N; Hu P; Hu X; Han G; Zhou Y; Bai W; Niu T; Yang X
    J Magn Reson Imaging; 2016 Jul; 44(1):98-104. PubMed ID: 26707910
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Quantification of Liver Fibrosis at T1 and T2 Mapping with Extracellular Volume Fraction MRI: Preclinical Results.
    Luetkens JA; Klein S; Träber F; Schmeel FC; Sprinkart AM; Kuetting DLR; Block W; Uschner FE; Schierwagen R; Hittatiya K; Kristiansen G; Gieseke J; Schild HH; Trebicka J; Kukuk GM
    Radiology; 2018 Sep; 288(3):748-754. PubMed ID: 29944086
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Myocardial T
    Weingärtner S; Meßner NM; Budjan J; Loßnitzer D; Mattler U; Papavassiliu T; Zöllner FG; Schad LR
    J Cardiovasc Magn Reson; 2016 Nov; 18(1):84. PubMed ID: 27855705
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Multiparametric magnetic resonance for the non-invasive diagnosis of liver disease.
    Banerjee R; Pavlides M; Tunnicliffe EM; Piechnik SK; Sarania N; Philips R; Collier JD; Booth JC; Schneider JE; Wang LM; Delaney DW; Fleming KA; Robson MD; Barnes E; Neubauer S
    J Hepatol; 2014 Jan; 60(1):69-77. PubMed ID: 24036007
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Staging liver fibrosis in chronic hepatitis B with T
    Yang L; Ding Y; Rao S; Chen C; Wu L; Sheng R; Fu C; Zeng M
    J Magn Reson Imaging; 2017 Apr; 45(4):1186-1194. PubMed ID: 27563840
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Histological Validation of measurement of diffuse interstitial myocardial fibrosis by myocardial extravascular volume fraction from Modified Look-Locker imaging (MOLLI) T1 mapping at 3 T.
    de Meester de Ravenstein C; Bouzin C; Lazam S; Boulif J; Amzulescu M; Melchior J; Pasquet A; Vancraeynest D; Pouleur AC; Vanoverschelde JL; Gerber BL
    J Cardiovasc Magn Reson; 2015 Jun; 17(1):48. PubMed ID: 26062931
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Simultaneous T1 and T2 quantification of the myocardium using cardiac balanced-SSFP inversion recovery with interleaved sampling acquisition (CABIRIA).
    Santini F; Kawel-Boehm N; Greiser A; Bremerich J; Bieri O
    Magn Reson Med; 2015 Aug; 74(2):365-71. PubMed ID: 25113911
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Histological validation of cardiac magnetic resonance T
    Zeng M; Zhang N; He Y; Wen Z; Wang Z; Zhao Y; Greiser A; An J; Zhang T; Jing B; Zhang X; Fan Z; Li D
    J Magn Reson Imaging; 2016 Nov; 44(5):1179-1185. PubMed ID: 27061226
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of MR imaging with T1 and T2* mapping for the determination of hepatic iron overload.
    Henninger B; Kremser C; Rauch S; Eder R; Zoller H; Finkenstedt A; Michaely HJ; Schocke M
    Eur Radiol; 2012 Nov; 22(11):2478-86. PubMed ID: 22645044
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Parallel simulations for QUAntifying RElaxation magnetic resonance constants (SQUAREMR): an example towards accurate MOLLI T1 measurements.
    Xanthis CG; Bidhult S; Kantasis G; Heiberg E; Arheden H; Aletras AH
    J Cardiovasc Magn Reson; 2015 Nov; 17():104. PubMed ID: 26610703
    [TBL] [Abstract][Full Text] [Related]  

  • 36. T1 measurements in the human myocardium: the effects of magnetization transfer on the SASHA and MOLLI sequences.
    Robson MD; Piechnik SK; Tunnicliffe EM; Neubauer S
    Magn Reson Med; 2013 Sep; 70(3):664-70. PubMed ID: 23857710
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Inversion group (IG) fitting: A new T1 mapping method for modified look-locker inversion recovery (MOLLI) that allows arbitrary inversion groupings and rest periods (including no rest period).
    Sussman MS; Yang IY; Fok KH; Wintersperger BJ
    Magn Reson Med; 2016 Jun; 75(6):2332-40. PubMed ID: 26122489
    [TBL] [Abstract][Full Text] [Related]  

  • 38. T1-refBlochi: high resolution 3D post-contrast T1 myocardial mapping based on a single 3D late gadolinium enhancement volume, Bloch equations, and a reference T1.
    Hu C; Sinusas AJ; Huber S; Thorn S; Stacy MR; Mojibian H; Peters DC
    J Cardiovasc Magn Reson; 2017 Aug; 19(1):63. PubMed ID: 28821300
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Inversion recovery at 7 T in the human myocardium: measurement of T(1), inversion efficiency and B(1) (+).
    Rodgers CT; Piechnik SK; Delabarre LJ; Van de Moortele PF; Snyder CJ; Neubauer S; Robson MD; Vaughan JT
    Magn Reson Med; 2013 Oct; 70(4):1038-46. PubMed ID: 23197329
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of multislice breath-hold and 3D respiratory triggered T1 ρ imaging of liver in healthy volunteers and liver cirrhosis patients in 3.0 T MRI.
    Yang Q; Yu T; Yun S; Zhang H; Chen X; Cheng Z; Zhong J; Huang J; Okuaki T; Chan Q; Liang B; Guo H
    J Magn Reson Imaging; 2016 Oct; 44(4):906-13. PubMed ID: 27149283
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.