These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
390 related articles for article (PubMed ID: 27451079)
1. Stability of the distal phalanx fracture - A biomechanical study on the importance of the nail and the influence of fixation by crossing Kirschner wires. Wang W; Yu J; Fan CY; Liu S; Zheng X Clin Biomech (Bristol); 2016 Aug; 37():137-140. PubMed ID: 27451079 [TBL] [Abstract][Full Text] [Related]
2. [Clinical and radiological results after operative treatment of mallet fracture using Kirschner wire technique]. Reissner L; Gienck M; Weishaupt D; Platz A; Kilgus M Handchir Mikrochir Plast Chir; 2012 Jan; 44(1):11-6. PubMed ID: 22065287 [TBL] [Abstract][Full Text] [Related]
3. Fixation for comminuted phalangeal fractures. A biomechanical study of five methods. Lu WW; Furumachi K; Ip WY; Chow SP J Hand Surg Br; 1996 Dec; 21(6):765-7. PubMed ID: 8982920 [TBL] [Abstract][Full Text] [Related]
4. External fixation for comminuted phalangeal fractures. A biomechanical cadaver study. Fitoussi F; Ip WY; Chow SP J Hand Surg Br; 1996 Dec; 21(6):760-4. PubMed ID: 8982919 [TBL] [Abstract][Full Text] [Related]
5. Comparative mechanical properties of various Kirschner wire configurations in transverse and oblique phalangeal fractures. Viegas SF; Ferren EL; Self J; Tencer AF J Hand Surg Am; 1988 Mar; 13(2):246-53. PubMed ID: 3351253 [TBL] [Abstract][Full Text] [Related]
6. Osteosynthesis of Phalangeal Fractures: Biomechanical Comparison of Kirschner Wires, Plates, and Compression Screws. Rausch V; Harbrecht A; Kahmann SL; Fenten T; Jovanovic N; Hackl M; Müller LP; Staat M; Wegmann K J Hand Surg Am; 2020 Oct; 45(10):987.e1-987.e8. PubMed ID: 32499069 [TBL] [Abstract][Full Text] [Related]
7. A method of treating comminuted phalangeal fractures by ligamentotaxis using a single Kirschner wire. Rex C; Patel K; Sandeep KM J Hand Surg Eur Vol; 2017 Nov; 42(9):971-972. PubMed ID: 28673103 [No Abstract] [Full Text] [Related]
8. [Effectiveness of Kirschner wire fixation for proximal phalangeal bone avulsion fracture caused by A2 circular trochlea injury of flexor digitorum tendon]. Yang H; Wang B; Guo L; Liu Z; Li Q Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2024 May; 38(5):583-587. PubMed ID: 38752245 [TBL] [Abstract][Full Text] [Related]
9. Correlation between extension-block K-wire insertion angle and postoperative extension loss in mallet finger fracture. Lee SK; Kim YH; Moon KH; Choy WS Orthop Traumatol Surg Res; 2018 Feb; 104(1):127-132. PubMed ID: 29024745 [TBL] [Abstract][Full Text] [Related]
10. Two-part surgical neck fractures of the proximal part of the humerus. A biomechanical evaluation of two fixation techniques. Edwards SL; Wilson NA; Zhang LQ; Flores S; Merk BR J Bone Joint Surg Am; 2006 Oct; 88(10):2258-64. PubMed ID: 17015605 [TBL] [Abstract][Full Text] [Related]
11. Percutaneous cerclage wiring technique for phalangeal fractures. Shim WC; Yang JW; Roh SY; Lee DC; Kim JS Tech Hand Up Extrem Surg; 2014 Mar; 18(1):36-40. PubMed ID: 24322367 [TBL] [Abstract][Full Text] [Related]
12. [MODIFIED INTRAMEDULLARY FIXATION WITH TWO Kirschner WIRES FOR EXTRA-ARTICULAR FRACTURE OF PROXIMAL PHALANGEAL BASE]. Li S; Wu K; Xie L; Chen L Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2016 Aug; 30(8):935-938. PubMed ID: 29786219 [TBL] [Abstract][Full Text] [Related]
13. [Lesions of peripheral structures of cadaver fingers caused by Kirschner wires]. Pointinger H; Munk P; Poeschl G; Schreiber M Unfallchirurg; 2000 Mar; 103(3):203-7. PubMed ID: 10800383 [TBL] [Abstract][Full Text] [Related]
14. Needle-in-needle Pinning Technique Using Disposable Hypodermic Needles for Fractures of Distal Phalanx With Dorsal Disruption. Takamoto K; Takano S; Takano K Tech Hand Up Extrem Surg; 2021 May; 26(1):42-46. PubMed ID: 33973945 [TBL] [Abstract][Full Text] [Related]
15. Fractures of the proximal phalanx and metacarpals in the hand: preferred methods of stabilization. Henry MH J Am Acad Orthop Surg; 2008 Oct; 16(10):586-95. PubMed ID: 18832602 [TBL] [Abstract][Full Text] [Related]
16. Cemented K-wire fixation for the treatment of shaft fractures of middle phalanges. Zhang X; Shao X; Zhang Z; Zhang G; Yu Y; Wang L; Lyu L Injury; 2018 Feb; 49(2):351-358. PubMed ID: 29055495 [TBL] [Abstract][Full Text] [Related]
17. Biomechanical evaluation of fixation of intra-articular fractures of the distal part of the radius in cadavera: Kirschner wires compared with calcium-phosphate bone cement. Yetkinler DN; Ladd AL; Poser RD; Constantz BR; Carter D J Bone Joint Surg Am; 1999 Mar; 81(3):391-9. PubMed ID: 10199278 [TBL] [Abstract][Full Text] [Related]
18. Intramedullary fixation by resorbable rods in a comminuted phalangeal fracture model. A biomechanical study. Roure P; Ip WY; Lu W; Chow SP; Gogolewski S J Hand Surg Br; 1999 Aug; 24(4):476-81. PubMed ID: 10473162 [TBL] [Abstract][Full Text] [Related]
19. A biomechanical comparison of Kirschner-wire fixation on fracture stability in Salter-Harris type I fractures of the proximal humeral physis in a porcine cadaveric model. Ma J; Wang T; Lovric V; Johnson KA; Walsh WR BMC Vet Res; 2017 Oct; 13(1):306. PubMed ID: 29070026 [TBL] [Abstract][Full Text] [Related]