These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

190 related articles for article (PubMed ID: 27454197)

  • 1. Effect of screw position on load transfer in lumbar pedicle screws: a non-idealized finite element analysis.
    Newcomb AG; Baek S; Kelly BP; Crawford NR
    Comput Methods Biomech Biomed Engin; 2017 Feb; 20(2):182-192. PubMed ID: 27454197
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of screw tunnels on the biomechanical stability of vertebral body after pedicle screws removal: a finite element analysis.
    Liu JM; Zhang Y; Zhou Y; Chen XY; Huang SH; Hua ZK; Liu ZL
    Int Orthop; 2017 Jun; 41(6):1183-1187. PubMed ID: 28353052
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Selection of suitable pedicle screw for degenerated cortical and cancellous bone of human lumbar spine: A finite element study.
    Jain P; Khan MR
    Int J Artif Organs; 2021 May; 44(5):361-366. PubMed ID: 33045876
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical evaluation of lumbar pedicle screws in spondylolytic vertebrae: comparison of fixation strength between the traditional trajectory and a cortical bone trajectory.
    Matsukawa K; Yato Y; Imabayashi H; Hosogane N; Asazuma T; Chiba K
    J Neurosurg Spine; 2016 Jun; 24(6):910-5. PubMed ID: 26895531
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical evaluation of fixation strength among different sizes of pedicle screws using the cortical bone trajectory: what is the ideal screw size for optimal fixation?
    Matsukawa K; Yato Y; Imabayashi H; Hosogane N; Abe Y; Asazuma T; Chiba K
    Acta Neurochir (Wien); 2016 Mar; 158(3):465-71. PubMed ID: 26769471
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical evaluation of the fixation strength of lumbar pedicle screws using cortical bone trajectory: a finite element study.
    Matsukawa K; Yato Y; Imabayashi H; Hosogane N; Asazuma T; Nemoto K
    J Neurosurg Spine; 2015 Oct; 23(4):471-8. PubMed ID: 26161515
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Bilateral pedicle screw fixation provides superior biomechanical stability in transforaminal lumbar interbody fusion: a finite element study.
    Ambati DV; Wright EK; Lehman RA; Kang DG; Wagner SC; Dmitriev AE
    Spine J; 2015 Aug; 15(8):1812-22. PubMed ID: 24983669
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stress distribution in vertebral bone and pedicle screw and screw-bone load transfers among various fixation methods for lumbar spine surgical alignment: A finite element study.
    Xu M; Yang J; Lieberman I; Haddas R
    Med Eng Phys; 2019 Jan; 63():26-32. PubMed ID: 30344069
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vitro validation of a novel mechanical model for testing the anchorage capacity of pedicle screws using physiological load application.
    Liebsch C; Zimmermann J; Graf N; Schilling C; Wilke HJ; Kienle A
    J Mech Behav Biomed Mater; 2018 Jan; 77():578-585. PubMed ID: 29096123
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Finite element analysis of the effects of pedicle screw fixation nut loosening on lumbar interbody fusion based on the elasto-plateau plasticity of bone characteristics.
    Kim Y; Kim TW
    Spine (Phila Pa 1976); 2010 Mar; 35(6):599-606. PubMed ID: 20139810
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Modelling tri-cortical pedicle screw fixation in thoracic vertebrae under osteoporotic condition: A finite element analysis based on computed tomography.
    Zhang W; Zhao J; Li L; Yu C; Zhao Y; Si H
    Comput Methods Programs Biomed; 2020 Apr; 187():105035. PubMed ID: 31443980
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical analysis of differing pedicle screw insertion angles.
    Sterba W; Kim DG; Fyhrie DP; Yeni YN; Vaidya R
    Clin Biomech (Bristol, Avon); 2007 May; 22(4):385-91. PubMed ID: 17208340
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stress distribution of different lumbar posterior pedicle screw insertion techniques: a combination study of finite element analysis and biomechanical test.
    Song M; Sun K; Li Z; Zong J; Tian X; Ma K; Wang S
    Sci Rep; 2021 Jun; 11(1):12968. PubMed ID: 34155224
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fatigue Performance of Cortical Bone Trajectory Screw Compared With Standard Trajectory Pedicle Screw.
    Akpolat YT; İnceoğlu S; Kinne N; Hunt D; Cheng WK
    Spine (Phila Pa 1976); 2016 Mar; 41(6):E335-41. PubMed ID: 26555831
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Treatment of thoracolumbar burst fractures by short-segment pedicle screw fixation using a combination of two additional pedicle screws and vertebroplasty at the level of the fracture: a finite element analysis.
    Liao JC; Chen WP; Wang H
    BMC Musculoskelet Disord; 2017 Jun; 18(1):262. PubMed ID: 28619021
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Perforations and angulations of 324 cervical medial cortical pedicle screws: a possible guide to avoid lateral perforations with use of pedicle screws in lower cervical spine.
    Mahesh B; Upendra B; Vijay S; Arun K; Srinivasa R
    Spine J; 2017 Mar; 17(3):457-465. PubMed ID: 27865885
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Thoracic pedicle screw fixation under axial and perpendicular loadings: A comprehensive numerical analysis.
    Bianco RJ; Arnoux PJ; Mac-Thiong JM; Aubin CE
    Clin Biomech (Bristol, Avon); 2019 Aug; 68():190-196. PubMed ID: 31238188
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Individualized prediction of pedicle screw fixation strength with a finite element model.
    Widmer J; Fasser MR; Croci E; Spirig J; Snedeker JG; Farshad M
    Comput Methods Biomech Biomed Engin; 2020 Mar; 23(4):155-167. PubMed ID: 31910656
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of pedicle screw redirection after lateral wall breach--a biomechanical study using human lumbar vertebrae.
    Stauff MP; Freedman BA; Kim JH; Hamasaki T; Yoon ST; Hutton WC
    Spine J; 2014 Jan; 14(1):98-103. PubMed ID: 23623630
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of Pedicle Screw Fixation Strength Among Different Transpedicular Trajectories: A Finite Element Study.
    Matsukawa K; Yato Y; Hynes RA; Imabayashi H; Hosogane N; Yoshihara Y; Asazuma T; Nemoto K
    Clin Spine Surg; 2017 Aug; 30(7):301-307. PubMed ID: 28746125
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.