  • 1. A novel phantom and procedure providing submillimeter accuracy in daily QA tests of accelerators used for stereotactic radiosurgery*.
    Brezovich IA; Popple RA; Duan J; Shen S; Wu X; Benhabib S; Huang M; Cardan RA
    J Appl Clin Med Phys; 2016 Jul; 17(4):246-253. PubMed ID: 27455506
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Efficient quality assurance method with automated data acquisition of a single phantom setup to determine radiation and imaging isocenter congruence.
    Kang H; Patel R; Roeske JC
    J Appl Clin Med Phys; 2019 Oct; 20(10):127-133. PubMed ID: 31535781
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Feasibility of virtual starshot analysis providing submillimeter radiation isocenter accuracy: A long-term multi-institutional analysis.
    Akino Y; Fujiwara M; Mizuno H; Shiomi H; Kaneko A; Isohashi F; Seo Y; Suzuki O; Otani K; Tamari K; Ogawa K
    J Appl Clin Med Phys; 2019 Oct; 20(10):74-83. PubMed ID: 31502408
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessment of image quality and dose calculation accuracy on kV CBCT, MV CBCT, and MV CT images for urgent palliative radiotherapy treatments.
    Held M; Cremers F; Sneed PK; Braunstein S; Fogh SE; Nakamura J; Barani I; Perez-Andujar A; Pouliot J; Morin O
    J Appl Clin Med Phys; 2016 Mar; 17(2):279-290. PubMed ID: 27074487
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An integrated quality assurance phantom for frameless single-isocenter multitarget stereotactic radiosurgery.
    Capaldi DPI; Skinner LB; Dubrowski P; Yu AS
    Phys Med Biol; 2020 Jun; 65(11):115006. PubMed ID: 32235050
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A positioning QA procedure for 2D/2D (kV/MV) and 3D/3D (CT/CBCT) image matching for radiotherapy patient setup.
    Guan H; Hammoud R; Yin FF
    J Appl Clin Med Phys; 2009 Oct; 10(4):273-280. PubMed ID: 19918223
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Stereotactic radiosurgery with MLC-defined arcs: Verification of dosimetry, spatial accuracy, and end-to-end tests.
    Brezovich IA; Wu X; Popple RA; Covington E; Cardan R; Shen S; Fiveash J; Bredel M; Guthrie B
    J Appl Clin Med Phys; 2019 May; 20(5):84-98. PubMed ID: 30977297
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A quality assurance procedure to evaluate cone-beam CT image center congruence with the radiation isocenter of a linear accelerator.
    Du W; Yang JN; Chang EL; Luo D; McAleer MF; Shiu A; Martel MK
    J Appl Clin Med Phys; 2010 Jul; 11(4):3297. PubMed ID: 21081890
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of a dedicated phantom for multi-target single-isocentre stereotactic radiosurgery end to end testing.
    Poder J; Brown R; Porter H; Gupta R; Ralston A
    J Appl Clin Med Phys; 2018 Nov; 19(6):99-108. PubMed ID: 30221462
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The spatial accuracy of two frameless, linear accelerator-based systems for single-isocenter, multitarget cranial radiosurgery.
    Ezzell GA
    J Appl Clin Med Phys; 2017 Mar; 18(2):37-43. PubMed ID: 28300379
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Alignment of multiradiation isocenters for megavoltage photon beam.
    Zhang Y; Ding K; Cowan G; Tryggestad E; Armour E; Wang KK
    J Appl Clin Med Phys; 2015 Nov; 16(6):314-324. PubMed ID: 26699586
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characteristics of a novel treatment system for linear accelerator-based stereotactic radiosurgery.
    Wen N; Li H; Song K; Chin-Snyder K; Qin Y; Kim J; Bellon M; Gulam M; Gardner S; Doemer A; Devpura S; Gordon J; Chetty I; Siddiqui F; Ajlouni M; Pompa R; Hammoud Z; Simoff M; Kalkanis S; Movsas B; Siddiqui MS
    J Appl Clin Med Phys; 2015 Jul; 16(4):125–148. PubMed ID: 26218998
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intrafraction 4D-cone beam CT acquired during volumetric arc radiotherapy delivery: kV parameter optimization and 4D motion accuracy for lung stereotactic body radiotherapy (SBRT) patients.
    Liang J; Lack D; Zhou J; Liu Q; Grills I; Yan D
    J Appl Clin Med Phys; 2019 Dec; 20(12):10-24. PubMed ID: 31675150
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comprehensive radiation and imaging isocenter verification using NIPAM kV-CBCT dosimetry.
    Pant K; Umeh C; Oldham M; Floyd S; Giles W; Adamson J
    Med Phys; 2020 Mar; 47(3):927-936. PubMed ID: 31899806
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Feasibility of using cone-beam CT to verify and reposition the optically guided target localization of linear accelerator based stereotactic radiosurgery.
    Zhu J
    Med Phys; 2011 Jan; 38(1):390-6. PubMed ID: 21361207
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Positioning accuracy of a single-isocenter multiple targets SRS treatment: A comparison between Varian TrueBeam CBCT and Brainlab ExacTrac.
    Graulieres E; Kubler S; Martin E; Ferrand R
    Phys Med; 2020 Dec; 80():267-273. PubMed ID: 33221708
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Initial application of a geometric QA tool for integrated MV and kV imaging systems on three image guided radiotherapy systems.
    Mao W; Speiser M; Medin P; Papiez L; Solberg T; Xing L
    Med Phys; 2011 May; 38(5):2335-41. PubMed ID: 21776767
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of the cone beam CT for internal target volume localization in lung stereotactic radiotherapy in comparison with 4D MIP images.
    Wang L; Chen X; Lin MH; Xue J; Lin T; Fan J; Jin L; Ma CM
    Med Phys; 2013 Nov; 40(11):111709. PubMed ID: 24320417
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of the truebeam machine performance check (MPC): OBI X-ray tube alignment procedure.
    Barnes MP; Pomare D; Menk FW; Moraro B; Greer PB
    J Appl Clin Med Phys; 2018 Nov; 19(6):68-78. PubMed ID: 30178521
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of commissioning criteria for multileaf-collimator, stereotactic radiosurgery treatments on Varian TrueBeam and Edge machines using a novel anthropomorphic phantom.
    Brown TAD; Fagerstrom JM; Beck C; Holloway C; Burton K; Kaurin DGL; Mahendra S; Luckstead M; Kielar K; Kerns J
    J Appl Clin Med Phys; 2022 Jun; 23(6):e13581. PubMed ID: 35290710
    [TBL] [Abstract][Full Text] [Related]  