These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

254 related articles for article (PubMed ID: 27456134)

  • 1. Investigation of a novel implantable suprachoroidal pressure transducer for telemetric intraocular pressure monitoring.
    Mariacher S; Ebner M; Januschowski K; Hurst J; Schnichels S; Szurman P
    Exp Eye Res; 2016 Oct; 151():54-60. PubMed ID: 27456134
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Implantation and testing of a novel episcleral pressure transducer: A new approach to telemetric intraocular pressure monitoring.
    Mariacher S; Ebner M; Hurst J; Szurman P; Januschowski K
    Exp Eye Res; 2018 Jan; 166():84-90. PubMed ID: 29066280
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Implantation of a novel telemetric intraocular pressure sensor in patients with glaucoma (ARGOS study): 1-year results.
    Koutsonas A; Walter P; Roessler G; Plange N
    Invest Ophthalmol Vis Sci; 2015 Jan; 56(2):1063-9. PubMed ID: 25613949
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Long-term follow-up after implantation of a telemetric intraocular pressure sensor in patients with glaucoma: a safety report.
    Koutsonas A; Walter P; Roessler G; Plange N
    Clin Exp Ophthalmol; 2018 Jul; 46(5):473-479. PubMed ID: 29136327
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Telemetric Measurement of Intraocular Pressure via an Implantable Pressure Sensor-12-Month Results from the ARGOS-02 Trial.
    Choritz L; Mansouri K; van den Bosch J; Weigel M; Dick HB; Wagner M; Thieme H;
    Am J Ophthalmol; 2020 Jan; 209():187-196. PubMed ID: 31545953
    [TBL] [Abstract][Full Text] [Related]  

  • 6. EYEMATE-SC Trial: Twelve-Month Safety, Performance, and Accuracy of a Suprachoroidal Sensor for Telemetric Measurement of Intraocular Pressure.
    Szurman P; Gillmann K; Seuthe AM; Dick HB; Hoffmann EM; Mermoud A; Mackert MJ; Weinreb RN; Rao HL; Mansouri K;
    Ophthalmology; 2023 Mar; 130(3):304-312. PubMed ID: 36202141
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Preliminary study on implantable inductive-type sensor for continuous monitoring of intraocular pressure.
    Kim YW; Kim MJ; Park KH; Jeoung JW; Kim SH; Jang CI; Lee SH; Kim JH; Lee S; Kang JY
    Clin Exp Ophthalmol; 2015 Dec; 43(9):830-7. PubMed ID: 26146890
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Weekly and seasonal changes of intraocular pressure measured with an implanted intraocular telemetry sensor.
    Mansouri K; Gillmann K; Rao HL; Weinreb RN;
    Br J Ophthalmol; 2021 Mar; 105(3):387-391. PubMed ID: 32499329
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of a completely encapsulated intraocular pressure sensor.
    Walter P; Schnakenberg U; vom Bögel G; Ruokonen P; Krüger C; Dinslage S; Lüdtke Handjery HC; Richter H; Mokwa W; Diestelhorst M; Krieglstein GK
    Ophthalmic Res; 2000; 32(6):278-84. PubMed ID: 11015039
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Self-tonometry with a Telemetric Intraocular Pressure Sensor in Patients With Glaucoma].
    Koutsonas A; Walter P; Plange N
    Klin Monbl Augenheilkd; 2016 Jun; 233(6):743-8. PubMed ID: 26609675
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A novel approach to suprachoroidal drainage for the surgical treatment of intractable glaucoma.
    Jordan JF; Engels BF; Dinslage S; Dietlein TS; Ayertey HD; Roters S; Esser P; Konen W; Krieglstein GK
    J Glaucoma; 2006 Jun; 15(3):200-5. PubMed ID: 16778641
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Telemetric Intraocular Pressure Monitoring after Boston Keratoprosthesis Surgery Using the Eyemate-IO Sensor: Dynamics in the First Year.
    Enders P; Hall J; Bornhauser M; Mansouri K; Altay L; Schrader S; Dietlein TS; Bachmann BO; Neuhann T; Cursiefen C
    Am J Ophthalmol; 2019 Oct; 206():256-263. PubMed ID: 30849343
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Implanted Microsensor Continuous IOP Telemetry Suggests Gaze and Eyelid Closure Effects on IOP-A Preliminary Study.
    van den Bosch JJON; Pennisi V; Invernizzi A; Mansouri K; Weinreb RN; Thieme H; Hoffmann MB; Choritz L
    Invest Ophthalmol Vis Sci; 2021 May; 62(6):8. PubMed ID: 33956052
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intraocular pressure measurement by radio wave telemetry.
    Todani A; Behlau I; Fava MA; Cade F; Cherfan DG; Zakka FR; Jakobiec FA; Gao Y; Dohlman CH; Melki SA
    Invest Ophthalmol Vis Sci; 2011 Dec; 52(13):9573-80. PubMed ID: 22039243
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Telemetric non-contact intraocular pressure monitoring with an implanted sensor in patients with glaucoma: long-term safety report and monitoring data.
    Schmidt I; Plange N; Walter P; Koutsonas A
    Br J Ophthalmol; 2023 Aug; 107(8):1098-1103. PubMed ID: 35314512
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reproducibility of the water-drinking test in patients with exfoliation syndrome and exfoliative glaucoma.
    Özyol E; Özyol P; Karalezli A
    Acta Ophthalmol; 2016 Dec; 94(8):e795-e798. PubMed ID: 27316559
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Device profile of the EYEMATE-IO™ system for intraocular pressure monitoring: overview of its safety and efficacy.
    Enders P; Cursiefen C
    Expert Rev Med Devices; 2020 Jun; 17(6):491-497. PubMed ID: 32339024
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Suprachoroidal implant surgery in intractable glaucoma.
    Palamar M; Ates H; Oztas Z; Yusifov E
    Jpn J Ophthalmol; 2011 Jul; 55(4):351-355. PubMed ID: 21617958
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Trabeculotomy combined with phacoemulsification and implantation of intraocular lens for primary open-angle glaucoma.
    Mizoguchi T; Kuroda S; Terauchi H; Nagata M
    Semin Ophthalmol; 2001 Sep; 16(3):162-7. PubMed ID: 15513436
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Advances in telemetric continuous intraocular pressure assessment.
    Kakaday T; Hewitt AW; Voelcker NH; Li JS; Craig JE
    Br J Ophthalmol; 2009 Aug; 93(8):992-6. PubMed ID: 19244268
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.