155 related articles for article (PubMed ID: 27458053)
1. Experimental analysis of radiographer exposure to the static field from a 1.5-T magnetic resonance imaging machine.
Bonello J; Sammut CV
Int J Occup Saf Ergon; 2017 Mar; 23(1):133-138. PubMed ID: 27458053
[TBL] [Abstract][Full Text] [Related]
2. [Experimental evaluation of the occupational exposure to static magnetic fields on a 3 T magnetic resonance scanner].
Moro L; Alabiso F; Parisoli F; Frigerio F
G Ital Med Lav Ergon; 2013; 35(1):26-31. PubMed ID: 23798231
[TBL] [Abstract][Full Text] [Related]
3. Exposure to static and time-varying magnetic fields from working in the static magnetic stray fields of MRI scanners: a comprehensive survey in the Netherlands.
Schaap K; Christopher-De Vries Y; Crozier S; De Vocht F; Kromhout H
Ann Occup Hyg; 2014 Nov; 58(9):1094-110. PubMed ID: 25139484
[TBL] [Abstract][Full Text] [Related]
4. Analysis and measurements of magnetic field exposures for healthcare workers in selected MR environments.
Fuentes MA; Trakic A; Wilson SJ; Crozier S
IEEE Trans Biomed Eng; 2008 Apr; 55(4):1355-64. PubMed ID: 18390326
[TBL] [Abstract][Full Text] [Related]
5. Measurements of occupational exposure to switched gradient and spatially-varying magnetic fields in areas adjacent to 1.5 T clinical MRI systems.
Riches SF; Collins DJ; Charles-Edwards GD; Shafford JC; Cole J; Keevil SF; Leach MO
J Magn Reson Imaging; 2007 Nov; 26(5):1346-52. PubMed ID: 17969176
[TBL] [Abstract][Full Text] [Related]
6. Occupational exposure to static and time-varying gradient magnetic fields in MR units.
Bradley JK; Nyekiova M; Price DL; Lopez LD; Crawley T
J Magn Reson Imaging; 2007 Nov; 26(5):1204-9. PubMed ID: 17969141
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of exposure to (ultra) high static magnetic fields during activities around human MRI scanners.
Fatahi M; Karpowicz J; Gryz K; Fattahi A; Rose G; Speck O
MAGMA; 2017 Jun; 30(3):255-264. PubMed ID: 27981395
[TBL] [Abstract][Full Text] [Related]
8. Occupational Electromagnetic Fields exposure in Magnetic Resonance Imaging systems - Preliminary results for the RF harmonic content.
Gourzoulidis G; Karabetsos E; Skamnakis Ν; Xrtistodoulou A; Kappas C; Theodorou K; Tsougos I; Maris TG
Phys Med; 2015 Nov; 31(7):757-62. PubMed ID: 25843889
[TBL] [Abstract][Full Text] [Related]
9. [Health effects of occupational exposure to static magnetic fields used in magnetic resonance imaging: a review].
Franco G; Perduri R; Murolo A
Med Lav; 2008; 99(1):16-28. PubMed ID: 18254536
[TBL] [Abstract][Full Text] [Related]
10. [Exposure to static magnetic field and health hazards during the operation of magnetic resonance scanners].
Karpowicz J; Gryz K; Politański P; Zmyślony M
Med Pr; 2011; 62(3):309-21. PubMed ID: 21870421
[TBL] [Abstract][Full Text] [Related]
11. MRI 'EXPOSIMETRY': HOW TO ANALYZE, COMPARE AND REPRESENT WORKER EXPOSURE TO STATIC MAGNETIC FIELD?
Delmas A; Weber N; Piffre J; Pasquier C; Felblinger J; Vuissoz PA
Radiat Prot Dosimetry; 2017 Dec; 177(4):415-423. PubMed ID: 28499015
[TBL] [Abstract][Full Text] [Related]
12. [Study of occupational exposure to magnetic fields among operators of magnetic resonance scanning at the Papa Giovanni XXIII Hospital (Bergamo)].
Cretti FR; Gambirasio A
Med Lav; 2015 Jan; 106(1):3-16. PubMed ID: 25607283
[TBL] [Abstract][Full Text] [Related]
13. ASSESSMENT OF MOVEMENT-INDUCED TIME-VARYING MAGNETIC FIELDS EXPOSURE IN MAGNETIC RESONANCE IMAGING BY A COMMERCIAL PORTABLE MAGNETOMETER.
Filice S; Rossi R; Crisi G
Radiat Prot Dosimetry; 2019 Dec; 185(3):326-330. PubMed ID: 30806458
[TBL] [Abstract][Full Text] [Related]
14. Health risk assessment of occupational exposure to a magnetic field from magnetic resonance imaging devices.
Karpowicz J; Gryz K
Int J Occup Saf Ergon; 2006; 12(2):155-67. PubMed ID: 16790173
[TBL] [Abstract][Full Text] [Related]
15. Occupational exposure levels of static magnetic field during routine MRI examination in 3T MR system.
Yamaguchi-Sekino S; Nakai T; Imai S; Izawa S; Okuno T
Bioelectromagnetics; 2014 Jan; 35(1):70-5. PubMed ID: 24115150
[TBL] [Abstract][Full Text] [Related]
16. OCCUPATIONAL EXPOSURE OF NMR SPECTROMETRISTS TO STATIC AND RADIOFREQUENCY FIELDS.
Berlana T; Úbeda A
Radiat Prot Dosimetry; 2017 Dec; 177(4):397-406. PubMed ID: 28472522
[TBL] [Abstract][Full Text] [Related]
17. Occupational exposure in MR facilities due to movements in the static magnetic field.
Andreuccetti D; Biagi L; Burriesci G; Cannatà V; Contessa GM; Falsaperla R; Genovese E; Lodato R; Lopresto V; Merla C; Napolitano A; Pinto R; Tiberi G; Tosetti M; Zoppetti N
Med Phys; 2017 Nov; 44(11):5988-5996. PubMed ID: 28857189
[TBL] [Abstract][Full Text] [Related]
18. Personal exposure to static and time-varying magnetic fields during MRI procedures in clinical practice in the UK.
Batistatou E; Mölter A; Kromhout H; van Tongeren M; Crozier S; Schaap K; Gowland P; Keevil SF; de Vocht F
Occup Environ Med; 2016 Nov; 73(11):779-786. PubMed ID: 26675205
[TBL] [Abstract][Full Text] [Related]
19. Personal exposure to static and time-varying magnetic fields during MRI system test procedures.
de Vocht F; Muller F; Engels H; Kromhout H
J Magn Reson Imaging; 2009 Nov; 30(5):1223-8. PubMed ID: 19856458
[TBL] [Abstract][Full Text] [Related]
20. Inventory of MRI applications and workers exposed to MRI-related electromagnetic fields in the Netherlands.
Schaap K; Christopher-De Vries Y; Slottje P; Kromhout H
Eur J Radiol; 2013 Dec; 82(12):2279-85. PubMed ID: 24055183
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]