BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

178 related articles for article (PubMed ID: 2745864)

  • 1. Transthoracic electrical bioimpedance versus thermodilution technique for cardiac output measurement during mechanical ventilation.
    Preiser JC; Daper A; Parquier JN; Contempré B; Vincent JL
    Intensive Care Med; 1989; 15(4):221-3. PubMed ID: 2745864
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transthoracic electrical bioimpedance versus thermodilution technique for cardiac output measurement during mechanical ventilation.
    Tremper K
    Intensive Care Med; 1989; 15(4):219-20. PubMed ID: 2745863
    [No Abstract]   [Full Text] [Related]  

  • 3. Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patients.
    Sageman WS; Amundson DE
    Crit Care Med; 1993 Aug; 21(8):1139-42. PubMed ID: 8339577
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of thermodilution and transthoracic electrical bioimpedance cardiac outputs.
    Woo MA; Hamilton M; Stevenson LW; Vredevoe DL
    Heart Lung; 1991 Jul; 20(4):357-62. PubMed ID: 2071427
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparison of hemodynamic parameters derived from transthoracic electrical bioimpedance with those parameters obtained by thermodilution and ventricular angiography.
    Marik PE; Pendelton JE; Smith R
    Crit Care Med; 1997 Sep; 25(9):1545-50. PubMed ID: 9295830
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of cardiac output during positive end-expiratory pressure--noninvasive electrical bioimpedance compared with standard thermodilution.
    Castor G; Molter G; Helms J; Niedermark I; Altmayer P
    Crit Care Med; 1990 May; 18(5):544-6. PubMed ID: 2183967
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Esophageal electrodes allow precise assessment of cardiac output by bioimpedance.
    Balestra B; Malacrida R; Leonardi L; Suter P; Marone C
    Crit Care Med; 1992 Jan; 20(1):62-7. PubMed ID: 1729048
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of transthoracic electrical impedance and thermodilution methods for measuring cardiac output.
    Donovan KD; Dobb GJ; Woods WP; Hockings BE
    Crit Care Med; 1986 Dec; 14(12):1038-44. PubMed ID: 3780246
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: a comparison with pulmonary artery thermodilution.
    Suttner S; Schöllhorn T; Boldt J; Mayer J; Röhm KD; Lang K; Piper SN
    Intensive Care Med; 2006 Dec; 32(12):2053-8. PubMed ID: 17039348
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cardiac Output Measurement in Neonates and Children Using Noninvasive Electrical Bioimpedance Compared With Standard Methods: A Systematic Review and Meta-Analysis.
    Mansfield RC; Kaza N; Charalambous A; Milne AC; Sathiyamurthy S; Banerjee J
    Crit Care Med; 2022 Jan; 50(1):126-137. PubMed ID: 34325447
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance.
    Bernstein DP
    Crit Care Med; 1986 Oct; 14(10):898-901. PubMed ID: 3757531
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Standardization of non-invasive impedance cardiography for assessment of stroke volume: comparison with thermodilution.
    Woltjer HH; Bogaard HJ; Scheffer GJ; van der Spoel HI; Huybregts MA; de Vries PM
    Br J Anaesth; 1996 Dec; 77(6):748-52. PubMed ID: 9014628
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of cardiac output determined by bioimpedance, thermodilution, and the Fick method.
    Engoren M; Barbee D
    Am J Crit Care; 2005 Jan; 14(1):40-5. PubMed ID: 15608107
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Measurement of cardiac output by thoracic electrical bioimpedance or thermodilution].
    Jacob F; Mariot J; Frisoni A; Perrier JF; Voltz C; Strub P; Ethévenot G
    Ann Fr Anesth Reanim; 1988; 7(3):264-7. PubMed ID: 3408040
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impedance cardiography. Importance of the equation and the electrode configuration.
    van der Meer BJ; Woltjer HH; Sousman AM; Schreuder WO; Bulder ER; Huybregts MA; de Vries PM
    Intensive Care Med; 1996 Oct; 22(10):1120-4. PubMed ID: 8923081
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cardiac output measurement in critical care patients: Thoracic Electrical Bioimpedance versus thermodilution.
    Clancy TV; Norman K; Reynolds R; Covington D; Maxwell JG
    J Trauma; 1991 Aug; 31(8):1116-20; discussion 1120-1. PubMed ID: 1875438
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Bioimpedance versus thermodilution cardiac output measurement: the Bomed NCCOM3 after coronary bypass surgery.
    Thomas AN; Ryan J; Doran BR; Pollard BJ
    Intensive Care Med; 1991; 17(7):383-6. PubMed ID: 1774390
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of transthoracic electrical bioimpedance cardiac output measurement with thermodilution method in post coronary artery bypass graft patients.
    Sharma V; Singh A; Kansara B; Karlekar A
    Ann Card Anaesth; 2011; 14(2):104-10. PubMed ID: 21636930
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Whole-body impedance cardiography in the measurement of cardiac output.
    Kööbi T; Kaukinen S; Turjanmaa VM; Uusitalo AJ
    Crit Care Med; 1997 May; 25(5):779-85. PubMed ID: 9187596
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accurate, noninvasive continuous monitoring of cardiac output by whole-body electrical bioimpedance.
    Cotter G; Moshkovitz Y; Kaluski E; Cohen AJ; Miller H; Goor D; Vered Z
    Chest; 2004 Apr; 125(4):1431-40. PubMed ID: 15078756
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.