These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 27459672)

  • 1. Tissue phantom-based breast cancer detection using continuous near-infrared sensor.
    Liu D; Liu X; Zhang Y; Wang Q; Lu J
    Bioengineered; 2016 Sep; 7(5):321-326. PubMed ID: 27459672
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Feasibility of spatial frequency-domain imaging for monitoring palpable breast lesions.
    Robbins CM; Raghavan G; Antaki JF; Kainerstorfer JM
    J Biomed Opt; 2017 Aug; 22(12):1-9. PubMed ID: 28831792
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Imitation-tumor targeting based on continuous-wave near-infrared tomography.
    Liu D; Liu X; Zhang Y; Wang Q; Lu J; Sun J
    Comput Assist Surg (Abingdon); 2017 Dec; 22(sup1):157-162. PubMed ID: 29041839
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Validation of a high-power, time-resolved, near-infrared spectroscopy system for measurement of superficial and deep muscle deoxygenation during exercise.
    Koga S; Barstow TJ; Okushima D; Rossiter HB; Kondo N; Ohmae E; Poole DC
    J Appl Physiol (1985); 2015 Jun; 118(11):1435-42. PubMed ID: 25840439
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of the chest wall on the measurement of hemoglobin concentrations by near-infrared time-resolved spectroscopy in normal breast and cancer.
    Yoshizawa N; Ueda Y; Nasu H; Ogura H; Ohmae E; Yoshimoto K; Takehara Y; Yamashita Y; Sakahara H
    Breast Cancer; 2016 Nov; 23(6):844-850. PubMed ID: 26474784
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Opto-acoustic imaging of relative blood oxygen saturation and total hemoglobin for breast cancer diagnosis.
    Zalev J; Richards LM; Clingman BA; Harris J; Cantu E; Menezes GLG; Avila C; Bertrand A; Saenz X; Miller S; Oraevsky AA; Kolios MC
    J Biomed Opt; 2019 Dec; 24(12):1-16. PubMed ID: 31849204
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A prospective pilot clinical trial evaluating the utility of a dynamic near-infrared imaging device for characterizing suspicious breast lesions.
    Xu RX; Young DC; Mao JJ; Povoski SP
    Breast Cancer Res; 2007; 9(6):R88. PubMed ID: 18088411
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Visible and near-infrared spectroscopy for distinguishing malignant tumor tissue from benign tumor and normal breast tissues in vitro.
    Zhang Y; Chen Y; Yu Y; Xue X; Tuchin VV; Zhu D
    J Biomed Opt; 2013 Jul; 18(7):077003. PubMed ID: 23839487
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Phase-contrast imaging of tissue using near-infrared diffusing light.
    Jiang H; Xu Y
    Med Phys; 2003 Jun; 30(6):1048-51. PubMed ID: 12852528
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Calibration of near-infrared frequency-domain tissue spectroscopy for absolute absorption coefficient quantitation in neonatal head-simulating phantoms.
    Pogue BW; Paulsen KD; Abele C; Kaufman H
    J Biomed Opt; 2000 Apr; 5(2):185-93. PubMed ID: 10938782
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comment on the modified Beer-Lambert law for scattering media.
    Sassaroli A; Fantini S
    Phys Med Biol; 2004 Jul; 49(14):N255-7. PubMed ID: 15357206
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [The clinical detection of breast cancer by spectrum method].
    Gao TX; Fan XF; Xuan LX; Zhang BN; Li X; Bai J
    Guang Pu Xue Yu Guang Pu Fen Xi; 2008 Nov; 28(11):2531-5. PubMed ID: 19271483
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Tissue-simulating phantoms for assessing potential near-infrared fluorescence imaging applications in breast cancer surgery.
    Pleijhuis R; Timmermans A; De Jong J; De Boer E; Ntziachristos V; Van Dam G
    J Vis Exp; 2014 Sep; (91):51776. PubMed ID: 25286185
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Three-dimensional diffuse optical tomography in the parallel plane transmission geometry: evaluation of a hybrid frequency domain/continuous wave clinical system for breast imaging.
    Culver JP; Choe R; Holboke MJ; Zubkov L; Durduran T; Slemp A; Ntziachristos V; Chance B; Yodh AG
    Med Phys; 2003 Feb; 30(2):235-47. PubMed ID: 12607841
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Poly(vinyl alcohol) gels for use as tissue phantoms in photoacoustic mammography.
    Kharine A; Manohar S; Seeton R; Kolkman RG; Bolt RA; Steenbergen W; de Mul FF
    Phys Med Biol; 2003 Feb; 48(3):357-70. PubMed ID: 12608612
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Development of a Three-Wavelength Brain Tissue Oxygen Monitoring System Based on Near Infrared Spectrum].
    Li Z; Li H; Yin Q; Cai S; Ye J; Zhang X; Yu H; Gou D
    Zhongguo Yi Liao Qi Xie Za Zhi; 2024 Jan; 48(1):26-29. PubMed ID: 38384213
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Performance assessment of diffuse optical spectroscopic imaging instruments in a 2-year multicenter breast cancer trial.
    Leproux A; O'Sullivan TD; Cerussi A; Durkin A; Hill B; Hylton N; Yodh AG; Carp SA; Boas D; Jiang S; Paulsen KD; Pogue B; Roblyer D; Yang W; Tromberg BJ
    J Biomed Opt; 2017 Dec; 22(12):121604. PubMed ID: 29389104
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Assessing Absorption Coefficient of Hemoglobin in the Breast Phantom Using Near-Infrared Spectroscopy.
    Mehnati P; Jafari Tirtash M; Zakerhamidi MS; Mehnati P
    Iran J Radiol; 2016 Oct; 13(4):e31581. PubMed ID: 27895869
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Design and benchtop validation of a handheld integrated dynamic breast imaging system for noninvasive characterization of suspicious breast lesions.
    Xu RX; Ewing J; El-Dahdah H; Wang B; Povoski SP
    Technol Cancer Res Treat; 2008 Dec; 7(6):471-81. PubMed ID: 19044327
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Study on the noninvasive measurement of cerebral oxygen saturation and cerebral phronetal function].
    Yao P; Li S; Zhang A; Liu Y; Xu M; Jin T
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2001 Jun; 18(2):260-4. PubMed ID: 11450549
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.